Thread synchronisation fixed. Proper cookie copying.
authorKrzysztof Jackiewicz <k.jackiewicz@samsung.com>
Fri, 10 May 2013 12:53:05 +0000 (14:53 +0200)
committerBartlomiej Grzelewski <b.grzelewski@samsung.com>
Thu, 6 Feb 2014 16:09:35 +0000 (17:09 +0100)
commit57ae56603b247ce3f4a1010fec4c9b531c4b1f83
tree44ca806fabce11e4b95f20e8a69589c472094fcf
parent59c8d0e47b83cf503f581cf25d2ab79b72eb2641
Thread synchronisation fixed. Proper cookie copying.

[Issue#] SSDWSSP-237
[Feature/Bug] N/A
[Problem] security server crashes
[Cause] Because of incorrect synchronisation a race condition was possible
[Solution] Synchronisation fixed. Proper cookie copying applied.

[Verification] Run all security server tests

Change-Id: I464fb0cf05ec707191c32dde8b7b3de2b0fcdeb5
src/server/security-server-main.c