iio: adc: aspeed: Add divider flag to fix incorrect voltage reading.
The formula for the ADC sampling period in ast2400/ast2500 is:
ADC clock period = PCLK * 2 * (ADC0C[31:17] + 1) * (ADC0C[9:0])
When ADC0C[9:0] is set to 0 the sampling voltage will be lower than
expected, because the hardware may not have enough time to
charge/discharge to a stable voltage. This patch use the flag
CLK_DIVIDER_ONE_BASED which will use the raw value read from the
register, with the value of zero considered invalid to conform to the
corrected formula.
Fixes:
573803234e72 ("iio: Aspeed ADC")
Reported-by: Konstantin Klubnichkin <kitsok@yandex-team.ru>
Signed-off-by: Billy Tsai <billy_tsai@aspeedtech.com>
Reviewed-by: Joel Stanley <joel@jms.id.au>
Link: https://lore.kernel.org/r/20220221012705.22008-1-billy_tsai@aspeedtech.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>