clocksource/drivers/sp804: Avoid error on multiple instances
authorAndre Przywara <andre.przywara@arm.com>
Fri, 6 May 2022 16:25:22 +0000 (17:25 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Tue, 14 Jun 2022 16:36:22 +0000 (18:36 +0200)
commit55bfe858d0198379a0cfd6024dd4624b2c130a5a
tree7a58a129f9950177d20b83d6290fe10dccd9ae9d
parent368e68ad6da4317fc4170e8d92b51c13d1bfe7a7
clocksource/drivers/sp804: Avoid error on multiple instances

[ Upstream commit a98399cbc1e05f7b977419f03905501d566cf54e ]

When a machine sports more than one SP804 timer instance, we only bring
up the first one, since multiple timers of the same kind are not useful
to Linux. As this is intentional behaviour, we should not return an
error message, as we do today:
===============
[    0.000800] Failed to initialize '/bus@8000000/motherboard-bus@8000000/iofpga-bus@300000000/timer@120000': -22
===============

Replace the -EINVAL return with a debug message and return 0 instead.

Also we do not reach the init function anymore if the DT node is
disabled (as this is now handled by OF_DECLARE), so remove the explicit
check for that case.

This fixes a long standing bogus error when booting ARM's fastmodels.

Signed-off-by: Andre Przywara <andre.przywara@arm.com>
Reviewed-by: Robin Murphy <robin.murphy@arm.com>
Link: https://lore.kernel.org/r/20220506162522.3675399-1-andre.przywara@arm.com
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/clocksource/timer-sp804.c