board: ge: bx50v3: fix crystal bit
authorSebastian Reichel <sebastian.reichel@collabora.com>
Fri, 23 Apr 2021 14:15:07 +0000 (16:15 +0200)
committerStefano Babic <sbabic@denx.de>
Sun, 2 May 2021 10:46:54 +0000 (12:46 +0200)
commit512bda95ed08dee32853f55983caacf939ae7bd5
tree3ab68bcafec776321eaba18fedae464d743e119c
parentbd9059c477e5eafbad08ef24923222a191bc98a0
board: ge: bx50v3: fix crystal bit

The DA9063 enables the CRYSTAL bit by default, but there is no
crystal populated on the BA16 system on module. Without explicitly
clearing the CRYSTAL bit the system runs unstable and sometimes
reboots unexpectedly.

Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
board/ge/bx50v3/bx50v3.c