maru: rotary: Change event value
authorDongwoo Lee <dwoo08.lee@samsung.com>
Tue, 17 Mar 2020 02:39:31 +0000 (11:39 +0900)
committerSeung-Woo Kim <sw0312.kim@samsung.com>
Mon, 23 Mar 2020 06:41:39 +0000 (15:41 +0900)
commit50960d0b28b6da32fe780448eef36a745741c37e
tree1a378aab878d5ad3b47d443b2e6586d410d70d90
parent2eb2a352d46e116a4165fddcefbaf7cddbb973f1
maru: rotary: Change event value

Until Tizen 5.0, for detent/bezel input device, its event value
was in between -2 and 2, but value 1, meant starting movement to
counter clockwise or clockwise, and value -1, meant moving back
to original position, never used. Change event value of the
detent/bezel device for Tizen 5.5 and later version.

It changes detent/bezel input driver event interface, so user
input framework for detent/bezel input should be also changed.

Ref: https://review.tizen.org/gerrit/#/c/platform/upstream/enlightenment/+/220346/

Change-Id: Iaa8e76de94eb4254820d93865dab9d4f7006f4e4
Signed-off-by: Seung-Woo Kim <sw0312.kim@samsung.com>
Signed-off-by: Dongwoo Lee <dwoo08.lee@samsung.com>
drivers/maru/maru_virtio_rotary.c