clk: samsung: Fix m2m scaler clock on Exynos542x
authorAndrzej Pietrasiewicz <andrzej.p@samsung.com>
Fri, 29 Sep 2017 07:32:53 +0000 (09:32 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 10 Nov 2018 15:42:50 +0000 (07:42 -0800)
commit503c394139c94e263401ea59b1553e1916e110f2
treeca258be0488f805687368f93482c8365e630f8a9
parenta34dcf51b8a6a05dc544349c5b2e23097bbdbdce
clk: samsung: Fix m2m scaler clock on Exynos542x

[ Upstream commit c07c1a0f68d0f2f7ca9aff924e2772526027b019 ]

The TOP "aclk400_mscl" clock should be kept enabled all the time
to allow proper access to power management control for MSC power
domain and devices that are a part of it. This change is required
for the scaler to work properly after domain power on/off sequence.

Fixes: 318fa46cc60d ("clk/samsung: exynos542x: mark some clocks as critical")
Signed-off-by: Andrzej Pietrasiewicz <andrzej.p@samsung.com>
Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/clk/samsung/clk-exynos5420.c