dts: remove A53 frequency table greater than 1.5Ghz [1/1]
authorDianzhong Huo <dianzhong.huo@amlogic.com>
Tue, 22 Jan 2019 08:18:49 +0000 (16:18 +0800)
committerJianxin Pan <jianxin.pan@amlogic.com>
Tue, 22 Jan 2019 08:48:16 +0000 (00:48 -0800)
commit4f0528057281a5a54efed136a8f660d806644d59
treecdd984e5f32229f7f49f42e58f7c5ebf56c14eee
parent7ba5b20a70105648f6cce405a0efe7b2894a8a26
dts: remove A53 frequency table greater than 1.5Ghz [1/1]

PD#SWPL-4521

Problem:
New W411 reference board A53 power combine with vddee,
becaule vddee voltage set at 800mv,so need remove
A53 dvfs table which voltage greater than 800mv

Solution:
Remove A53 frequency table greater than 1.5Ghz

Verify:
Local

Change-Id: I05a2b51f704b25a0654881d6da3372fcd2f2a051
Signed-off-by: Dianzhong Huo <dianzhong.huo@amlogic.com>
arch/arm64/boot/dts/amlogic/g12b_a311x_w411_buildroot.dts