OMAP2+: voltage: enable VC bypass scale method when VC is initialized
authorKevin Hilman <khilman@ti.com>
Mon, 18 Jul 2011 22:48:22 +0000 (15:48 -0700)
committerKevin Hilman <khilman@ti.com>
Thu, 15 Sep 2011 18:39:10 +0000 (11:39 -0700)
commit4d47506a85a9f2e745dc63215594e9f799aff3dc
tree38b47aceb74731fbbcb3b8192748a67c704523eb
parentd84adcf46b9c235d1f4975b72a8c2763dbfb0081
OMAP2+: voltage: enable VC bypass scale method when VC is initialized

VC is initialized first, set default scaling method to VC bypass.
If/when VP is initialized, default scaling method will be changed to
VP force-update.

Enabling VC bypass as default as soon as VC is initialized allows for
VC bypass scaling to work when no VP is configured/initialized for a
given voltage domain.

Signed-off-by: Kevin Hilman <khilman@ti.com>
arch/arm/mach-omap2/voltage.c