net: hns3: disable phy loopback setting in hclge_mac_start_phy
authorYufeng Mo <moyufeng@huawei.com>
Fri, 30 Apr 2021 09:06:22 +0000 (17:06 +0800)
committerDavid S. Miller <davem@davemloft.net>
Fri, 30 Apr 2021 21:49:33 +0000 (14:49 -0700)
commit472497d0bdae890a896013332a0b673f9acdf2bf
treea42f82f9dea02a2f2ae77865b1037e4bbb3daee7
parent8c9200e387721c597baabb319b4bd1cdf1155e35
net: hns3: disable phy loopback setting in hclge_mac_start_phy

If selftest and reset are performed at the same time, the phy
loopback setting may be still in enable state after the reset,
and device cannot link up. So fix this issue by disabling phy
loopback before phy_start().

Fixes: 256727da7395 ("net: hns3: Add MDIO support to HNS3 Ethernet driver for hip08 SoC")
Signed-off-by: Yufeng Mo <moyufeng@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>