staging:iio:ad7606: fix voltage scales
authorAlexandru Ardelean <alexandru.ardelean@analog.com>
Thu, 13 Sep 2018 08:44:09 +0000 (11:44 +0300)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 21 Nov 2018 08:24:04 +0000 (09:24 +0100)
commit442b54290c782f22a848941064625cad3e263f39
treee2d561c510cb33eb0a9930a29d113a1a4eee81ee
parentd3835bb8fa6758b4f38da3741e206192a6340f90
staging:iio:ad7606: fix voltage scales

[ Upstream commit 4ee033301c898dd0835d035d0e0eb768a3d35da1 ]

Fixes commit 17be2a2905a6ec9aa27cd59521495e2f490d2af0 ("staging: iio:
ad7606: replace range/range_available with corresponding scale").

The AD7606 devices don't have a 2.5V voltage range, they have 5V & 10V
voltage range, which is selectable via the `gpio_range` descriptor.

The scales also seem to have been miscomputed, because when they were
applied to the raw values, the results differ from the expected values.
After checking the ADC transfer function in the datasheet, these were
re-computed.

Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/iio/adc/ad7606.c