ARM: dts: Add async-bridge clock to MFC power domain for Exynos5420
authorJavier Martinez Canillas <javier@osg.samsung.com>
Tue, 24 May 2016 17:41:02 +0000 (13:41 -0400)
committerMarek Szyprowski <m.szyprowski@samsung.com>
Thu, 23 Jun 2016 06:08:57 +0000 (08:08 +0200)
commit3fd1b2329e4dcb8c3a9ae5c5a868fadca741fb22
tree883b94a693cb634cc284a9f15fa2a77c35530494
parentdecc428cbaebd4252948f31834b35beab626e25f
ARM: dts: Add async-bridge clock to MFC power domain for Exynos5420

The MFC IP is also inter-connected by an Async-Bridge so the CLK_ACLK333
has to be ungated during a power domain switch. Trying to do it when the
clock is gated will fail and lead to an imprecise external abort error
when the driver tries to access the MFC registers with the PD disabled.

For example, if the s5p-mfc module is removed and the MFC PD turned off:

[  186.835606] Power domain power-domain@10044060 disable failed
[  186.835671] s5p-mfc 11000000.codec: Removing 11000000.codec
[  186.837670] Power domain power-domain@10044060 disable failed

And when the module is inserted again:

[ 2395.176956] s5p_mfc_wait_for_done_dev:34: Interrupt (dev->int_type:0, command:12) timed out
[ 2395.177031] s5p_mfc_init_hw:272: Failed to load firmware
[ 2395.177384] Unhandled fault: imprecise external abort (0x1406) at 0x00000000
[ 2395.177441] pgd = ec3b4000
[ 2395.177467] [00000000] *pgd=00000000
[ 2395.177507] Internal error: : 1406 [#1] PREEMPT SMP ARM
[ 2395.177550] Modules linked in: s5p_mfc mwifiex_sdio mwifiex uvcvideo s5p_jpeg v4l2_mem2mem videobuf2_vmalloc videobuf2_dma_contig videobuf2_memops videobuf2_v4l2 videobuf2_core v4l2_common videodev media [last unloaded: s5p_mfc]
[ 2395.177774] CPU: 1 PID: 2382 Comm: v4l_id Tainted: G        W       4.6.0-rc6-next-20160502-00010-g7730dc64d2c1-dirty #179
[ 2395.177857] Hardware name: SAMSUNG EXYNOS (Flattened Device Tree)
[ 2395.177906] task: ed275500 ti: e6c8c000 task.ti: e6c8c000
[ 2395.177996] PC is at s5p_mfc_reset+0x1c4/0x284 [s5p_mfc]
[ 2395.178057] LR is at s5p_mfc_reset+0x1a4/0x284 [s5p_mfc]

This patch fixes this issue by adding the CLK_ACLK333 as an Async-Bridge
clock for the MFC power domain, so the PD configuration works properly.

Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com>
Reviewed-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
[backport of mainline commit 94aed538e032d82287023beb9c59ee80f03a1493]
Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com>
Change-Id: I94aed538e032d82287023beb9c59ee80f03a1493
arch/arm/boot/dts/exynos5420.dtsi