mlxsw: core_hwmon: Adjust module label names based on MTCAP sensor counter
authorVadim Pasternak <vadimp@nvidia.com>
Thu, 24 Aug 2023 13:43:10 +0000 (15:43 +0200)
committerDavid S. Miller <davem@davemloft.net>
Fri, 25 Aug 2023 09:53:37 +0000 (10:53 +0100)
commit3fc134a07438055fc93ce1bbacf2702ddd09500c
treee6892e2516d5dd59d35c2a881591b0b8b79a4231
parentd7248f1cc835bd80e936dc5b2d94b149bdd0077d
mlxsw: core_hwmon: Adjust module label names based on MTCAP sensor counter

Transceiver module temperature sensors are indexed after ASIC and
platform sensors. The current label printing method does not take this
into account and simply prints the index of the transceiver module
sensor.

On new systems that have platform sensors this results in incorrect
(shifted) transceiver module labels being printed:

$ sensors
[...]
front panel 002:  +37.0°C  (crit = +70.0°C, emerg = +75.0°C)
front panel 003:  +47.0°C  (crit = +70.0°C, emerg = +75.0°C)
[...]

Fix by taking the sensor count into account. After the fix:

$ sensors
[...]
front panel 001:  +37.0°C  (crit = +70.0°C, emerg = +75.0°C)
front panel 002:  +47.0°C  (crit = +70.0°C, emerg = +75.0°C)
[...]

Fixes: a53779de6a0e ("mlxsw: core: Add QSFP module temperature label attribute to hwmon")
Signed-off-by: Vadim Pasternak <vadimp@nvidia.com>
Reviewed-by: Ido Schimmel <idosch@nvidia.com>
Signed-off-by: Petr Machata <petrm@nvidia.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/mellanox/mlxsw/core_hwmon.c