s390/vfio_ap: use TAPQ to verify reset in progress completes
To eliminate the repeated calls to the PQAP(ZAPQ) function to verify that
a reset in progress completed successfully and ensure that error response
codes get appropriately logged, let's call the apq_reset_check() function
when the ZAPQ response code indicates that a reset that is already in
progress.
Signed-off-by: Tony Krowiak <akrowiak@linux.ibm.com>
Reviewed-by: Jason J. Herne <jjherne@linux.ibm.com>
Reviewed-by: Harald Freudenberger <freude@linux.ibm.com>
Link: https://lore.kernel.org/r/20230118203111.529766-4-akrowiak@linux.ibm.com
Signed-off-by: Christian Borntraeger <borntraeger@linux.ibm.com>
Signed-off-by: Heiko Carstens <hca@linux.ibm.com>