iio: pressure: dps310: Reset chip after timeout
authorEddie James <eajames@linux.ibm.com>
Thu, 15 Sep 2022 19:57:19 +0000 (14:57 -0500)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 26 Oct 2022 10:34:19 +0000 (12:34 +0200)
commit39f4c90b99956e7f7fdf54f0014ba1deaa425cbc
tree593aeb36a957fd96f0deee2400799cd1a86c9ad6
parentbc493cd75466e4e04b3a2e65d2cef13d275c4d1d
iio: pressure: dps310: Reset chip after timeout

commit 7b4ab4abcea4c0c10b25187bf2569e5a07e9a20c upstream.

The DPS310 chip has been observed to get "stuck" such that pressure
and temperature measurements are never indicated as "ready" in the
MEAS_CFG register. The only solution is to reset the device and try
again. In order to avoid continual failures, use a boolean flag to
only try the reset after timeout once if errors persist.

Fixes: ba6ec48e76bc ("iio: Add driver for Infineon DPS310")
Cc: <stable@vger.kernel.org>
Signed-off-by: Eddie James <eajames@linux.ibm.com>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Link: https://lore.kernel.org/r/20220915195719.136812-3-eajames@linux.ibm.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>