net/mlx5e: Fix missing reset of SW metadata in Striding RQ reset
authorAya Levin <ayal@mellanox.com>
Thu, 12 Mar 2020 10:35:32 +0000 (12:35 +0200)
committerSaeed Mahameed <saeedm@mellanox.com>
Tue, 24 Mar 2020 21:43:02 +0000 (14:43 -0700)
commit39369fd536d485a99a59d8e357c0d4d3ce19a3b8
tree9a6127aec48cb91d11f1b5539472337a9dc7399f
parent1de0306c3a05d305e45b1f1fabe2f4e94222eb6b
net/mlx5e: Fix missing reset of SW metadata in Striding RQ reset

When resetting the RQ (moving RQ state from RST to RDY), the driver
resets the WQ's SW metadata.
In striding RQ mode, we maintain a field that reflects the actual
expected WQ head (including in progress WQEs posted to the ICOSQ).
It was mistakenly not reset together with the WQ. Fix this here.

Fixes: 8276ea1353a4 ("net/mlx5e: Report and recover from CQE with error on RQ")
Signed-off-by: Aya Levin <ayal@mellanox.com>
Reviewed-by: Tariq Toukan <tariqt@mellanox.com>
Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
drivers/net/ethernet/mellanox/mlx5/core/en/txrx.h