Rate control adjustment.
authorPaul Wilkins <paulwilkins@google.com>
Wed, 23 Apr 2014 00:09:47 +0000 (17:09 -0700)
committerYaowu Xu <yaowu@google.com>
Wed, 7 May 2014 20:56:05 +0000 (13:56 -0700)
commit38ff3e328f95c040f96de798d3d4ba3dd510ab43
tree10e0ce508c9574a7f7da7c6b712873d881052d5d
parentc4180f8f9c889e9d9f531c613a692f3317714ab4
Rate control adjustment.

Small adjustment to the active Q range calculations.
These changes should slightly extend the available Q range
for KF/GF/ARF and narrow it for other frames.

The results for this change in isolation are broadly positive
for SSIM and average PSNR and slightly up but mixed for opsnr.

derf +0.293% opsnr, +1.286% SSIM
std-hd + 0.528% opsnr, + 1.746% SSIM
yt +0.056% opsnr, +0.457% SSIM
yt-hd -0.147% opsnr, + 0.226% SSIM

Change-Id: If065280342027ecc5d44b49fc1d440dfef041002
vp9/encoder/vp9_ratectrl.c