EDAC/mce_amd: Use struct cpuinfo_x86.cpu_die_id for AMD NodeId
authorYazen Ghannam <yazen.ghannam@amd.com>
Mon, 9 Nov 2020 21:06:58 +0000 (21:06 +0000)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 30 Dec 2020 10:53:16 +0000 (11:53 +0100)
commit3897b71e1a68ce6962a29fe57372382a5eecc0f8
treecea722954fce473458b0c215ae1dbbdb6d953819
parent2081572eb105be127af7a34ba2b438df8dd07e56
EDAC/mce_amd: Use struct cpuinfo_x86.cpu_die_id for AMD NodeId

[ Upstream commit 8de0c9917cc1297bc5543b61992d5bdee4ce621a ]

The edac_mce_amd module calls decode_dram_ecc() on AMD Family17h and
later systems. This function is used in amd64_edac_mod to do
system-specific decoding for DRAM ECC errors. The function takes a
"NodeId" as a parameter.

In AMD documentation, NodeId is used to identify a physical die in a
system. This can be used to identify a node in the AMD_NB code and also
it is used with umc_normaddr_to_sysaddr().

However, the input used for decode_dram_ecc() is currently the NUMA node
of a logical CPU. In the default configuration, the NUMA node and
physical die will be equivalent, so this doesn't have an impact.

But the NUMA node configuration can be adjusted with optional memory
interleaving modes. This will cause the NUMA node enumeration to not
match the physical die enumeration. The mismatch will cause the address
translation function to fail or report incorrect results.

Use struct cpuinfo_x86.cpu_die_id for the node_id parameter to ensure the
physical ID is used.

Fixes: fbe63acf62f5 ("EDAC, mce_amd: Use cpu_to_node() to find the node ID")
Signed-off-by: Yazen Ghannam <yazen.ghannam@amd.com>
Signed-off-by: Borislav Petkov <bp@suse.de>
Link: https://lkml.kernel.org/r/20201109210659.754018-4-Yazen.Ghannam@amd.com
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/edac/mce_amd.c