thermal/drivers/tsens: Add timeout to get_temp_tsens_valid
authorAnsuel Smith <ansuelsmth@gmail.com>
Thu, 7 Oct 2021 17:28:59 +0000 (19:28 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 18 Nov 2021 18:16:16 +0000 (19:16 +0100)
commit3792174592b6650884d397c1b1e4e98153a00a2c
tree4f2e56fd15ef9949a0d5c80d58f0d36be3e3dfd7
parent660446ff86ca4f3617438f076f92cfb123cce3d4
thermal/drivers/tsens: Add timeout to get_temp_tsens_valid

[ Upstream commit d012f9189fda0f3a1b303780ba0bbc7298d0d349 ]

The function can loop and lock the system if for whatever reason the bit
for the target sensor is NEVER valid. This is the case if a sensor is
disabled by the factory and the valid bit is never reported as actually
valid. Add a timeout check and exit if a timeout occurs. As this is
a very rare condition, handle the timeout only if the first read fails.
While at it also rework the function to improve readability and convert
to poll_timeout generic macro.

Signed-off-by: Ansuel Smith <ansuelsmth@gmail.com>
Reviewed-by: Bjorn Andersson <bjorn.andersson@linaro.org>
Link: https://lore.kernel.org/r/20211007172859.583-1-ansuelsmth@gmail.com
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/thermal/qcom/tsens.c