upstream: [media] coda: allow more than four instances on CODA7541
authorPhilipp Zabel <p.zabel@pengutronix.de>
Mon, 30 Sep 2013 13:34:44 +0000 (10:34 -0300)
committerChanho Park <chanho61.park@samsung.com>
Tue, 18 Nov 2014 02:52:10 +0000 (11:52 +0900)
commit313a21a5e35908490b2d9d74cca7f85cfc545d26
tree45312e97fc8f7a528cc743c447e9ead26b998575
parent2898a4e32faa4f12b2fba8545715d1f04a89f175
upstream: [media] coda: allow more than four instances on CODA7541

With the new firmware, there are not anymore four register sets,
but a single register set, which the driver has to conserve across
context switches. This allows to handle more than four instances
at the same time.

Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
Signed-off-by: Kamil Debski <k.debski@samsung.com>
Signed-off-by: Mauro Carvalho Chehab <m.chehab@samsung.com>
drivers/media/platform/coda.c