ALSA: line6: Add a sanity check for invalid EPs
As syzkaller spotted, currently line6 drivers submit a URB with the
fixed EP without checking whether it's actually available, which may
result in a kernel warning like:
usb 1-1: BOGUS urb xfer, pipe 3 != type 1
------------[ cut here ]------------
WARNING: CPU: 0 PID: 24 at drivers/usb/core/urb.c:449
usb_submit_urb+0xf8a/0x11d0
Modules linked in:
CPU: 0 PID: 24 Comm: kworker/0:1 Not tainted
4.14.0-rc2-42613-g1488251d1a98 #238
Hardware name: QEMU Standard PC (i440FX + PIIX, 1996), BIOS Bochs 01/01/2011
Workqueue: usb_hub_wq hub_event
Call Trace:
line6_start_listen+0x55f/0x9e0 sound/usb/line6/driver.c:82
line6_init_cap_control sound/usb/line6/driver.c:690
line6_probe+0x7c9/0x1310 sound/usb/line6/driver.c:764
podhd_probe+0x64/0x70 sound/usb/line6/podhd.c:474
usb_probe_interface+0x35d/0x8e0 drivers/usb/core/driver.c:361
....
This patch adds a sanity check of validity of EPs at the device
initialization phase for avoiding the call with an invalid EP.
Reported-by: Andrey Konovalov <andreyknvl@google.com>
Tested-by: Andrey Konovalov <andreyknvl@google.com>
Signed-off-by: Takashi Iwai <tiwai@suse.de>