ixgbe: stop resetting SYSTIME in ixgbe_ptp_start_cyclecounter
The ixgbe_ptp_start_cyclecounter is intended to be called whenever the
cyclecounter parameters need to be changed.
Since commit
a9763f3cb54c ("ixgbe: Update PTP to support X550EM_x
devices"), this function has cleared the SYSTIME registers and reset the
TSAUXC DISABLE_SYSTIME bit.
While these need to be cleared during ixgbe_ptp_reset, it is wrong to clear
them during ixgbe_ptp_start_cyclecounter. This function may be called
during both reset and link status change. When link changes, the SYSTIME
counter is still operating normally, but the cyclecounter should be updated
to account for the possibly changed parameters.
Clearing SYSTIME when link changes causes the timecounter to jump because
the cycle counter now reads zero.
Extract the SYSTIME initialization out to a new function and call this
during ixgbe_ptp_reset. This prevents the timecounter adjustment and avoids
an unnecessary reset of the current time.
This also restores the original SYSTIME clearing that occurred during
ixgbe_ptp_reset before the commit above.
Reported-by: Steve Payne <spayne@aurora.tech>
Reported-by: Ilya Evenbach <ievenbach@aurora.tech>
Fixes: a9763f3cb54c ("ixgbe: Update PTP to support X550EM_x devices")
Signed-off-by: Jacob Keller <jacob.e.keller@intel.com>
Tested-by: Gurucharan <gurucharanx.g@intel.com> (A Contingent worker at Intel)
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>