clk: exynos5433: Fix CLK_PCLK_MONOTONIC_CNT clk register assignment
authorJonghwa Lee <jonghwa3.lee@samsung.com>
Mon, 27 Apr 2015 11:36:30 +0000 (20:36 +0900)
committerSylwester Nawrocki <s.nawrocki@samsung.com>
Wed, 29 Apr 2015 12:11:09 +0000 (14:11 +0200)
commit1a9f6c887db891ed477642c38a1e17ee23c3f02b
treefbd3287f4a9659db0fcac4d50f77cfb383c9fc83
parenta84d1f546c0ef11446d8db6fd1a2c8d24d107b0b
clk: exynos5433: Fix CLK_PCLK_MONOTONIC_CNT clk register assignment

CLK_PCLK_MONOTONIC_CNT clock had a wrong register assigned to it.
The correct register is ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT.

Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Reviewed-by: Krzysztof Kozlowski <k.kozlowski.k@gmail.com>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
drivers/clk/samsung/clk-exynos5433.c