IB/rxe: put the pool on allocation failure
authorDoug Ledford <dledford@redhat.com>
Mon, 9 Oct 2017 13:11:32 +0000 (09:11 -0400)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sun, 4 Nov 2018 13:52:42 +0000 (14:52 +0100)
commit18addd960fe854df99727139040535e72addc6ea
tree9acca1f910a575c421f219886656e6d275520474
parent8c954368de6915c4dcbbceca279758ab654bad37
IB/rxe: put the pool on allocation failure

[ Upstream commit 6b9f8970cd30929cb6b372fa44fa66da9e59c650 ]

If the allocation of elem fails, it is not sufficient to simply check
for NULL and return.  We need to also put our reference on the pool or
else we will leave the pool with a permanent ref count and we will never
be able to free it.

Fixes: 4831ca9e4a8e ("IB/rxe: check for allocation failure on elem")
Suggested-by: Leon Romanovsky <leon@kernel.org>
Signed-off-by: Doug Ledford <dledford@redhat.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/infiniband/sw/rxe/rxe_pool.c