nvmem: imx-ocotp: Change TIMING calculation to u-boot algorithm
The RELAX field of the OCOTP block is turning out as a zero on i.MX8MM.
This messes up the subsequent re-load of the fuse shadow registers.
After some discussion with people @ NXP its clear we have missed a trick
here in Linux.
The OCOTP fuse programming time has a physical minimum 'burn time' that is
not related to the ipg_clk.
We need to define the RELAX, STROBE_READ and STROBE_PROG fields in terms of
desired timings to allow for the burn-in to safely complete. Right now only
the RELAX field is calculated in terms of an absolute time and we are
ending up with a value of zero.
This patch inherits the u-boot timings for the OCOTP_TIMING calculation on
the i.MX6 and i.MX8. Those timings are known to work and critically specify
values such as STROBE_PROG as a minimum timing.
Fixes: 0642bac7da42 ("nvmem: imx-ocotp: add write support")
Signed-off-by: Bryan O'Donoghue <pure.logic@nexus-software.ie>
Suggested-by: Leonard Crestez <leonard.crestez@nxp.com>
Reviewed-by: Leonard Crestez <leonard.crestez@nxp.com>
Signed-off-by: Srinivas Kandagatla <srinivas.kandagatla@linaro.org>