i40e: correct check for reading TSYNINDX from the receive descriptor
authorJacob Keller <jacob.e.keller@intel.com>
Wed, 5 Oct 2016 16:30:42 +0000 (09:30 -0700)
committerJeff Kirsher <jeffrey.t.kirsher@intel.com>
Mon, 31 Oct 2016 21:26:40 +0000 (14:26 -0700)
commit144ed1763003c6a88a4b788cc5da1d8a1ddf061f
tree16c7cadf90020a44cca92360249d03758ffcca33
parent0093631966aad046ddf21e157a43765c295e16a3
i40e: correct check for reading TSYNINDX from the receive descriptor

When hardware has taken a timestamp for a received packet, it indicates
which RXTIME register the timestamp was placed in by some bits in the
receive descriptor. It uses 3 bits, one to indicate if the descriptor
index is valid (ie: there was a timestamp) and 2 bits to indicate which
of the 4 registers to read. However, the driver currently does not check
the TSYNVALID bit and only checks the index. It assumes a zero index
means no timestamp, and a non zero index means a timestamp occurred.
While this appears to be true, it prevents ever reading a timestamp in
RXTIME[0], and causes the first timestamp the device captures to be
ignored.

Fix this by using the TSYNVALID bit correctly as the true indicator of
whether the packet has an associated timestamp.

Also rename the variable rsyn to tsyn as this is more descriptive and
matches the register names.

Change-ID: I4437e8f3a3df2c2ddb458b0fb61420f3dafc4c12
Signed-off-by: Jacob Keller <jacob.e.keller@intel.com>
Tested-by: Andrew Bowers <andrewx.bowers@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>