scsi: megaraid_sas: Add support for High IOPS queues
authorChandrakanth Patil <chandrakanth.patil@broadcom.com>
Tue, 25 Jun 2019 11:04:31 +0000 (16:34 +0530)
committerMartin K. Petersen <martin.petersen@oracle.com>
Thu, 27 Jun 2019 04:07:35 +0000 (00:07 -0400)
commit132147d7f620eed4a7bee815eba03561258fc21e
tree98a5c222f35079fbce83e7518fc4a6c1ec36da4b
parent58136856167d10adc2a190aff88d13b33eafb9e2
scsi: megaraid_sas: Add support for High IOPS queues

Aero controllers support balanced performance mode through the ability to
configure queues with different properties.

Reply queues with interrupt coalescing enabled are called "high iops reply
queues" and reply queues with interrupt coalescing disabled are called "low
latency reply queues".

The driver configures a combination of high iops and low latency reply
queues if:

 - HBA is an AERO controller;

 - MSI-X vectors supported by the HBA is 128;

 - Total CPU count in the system more than high iops queue count;

 - Driver is loaded with default max_msix_vectors module parameter; and

 - System booted in non-kdump mode.

Signed-off-by: Kashyap Desai <kashyap.desai@broadcom.com>
Signed-off-by: Chandrakanth Patil <chandrakanth.patil@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
drivers/scsi/megaraid/megaraid_sas.h
drivers/scsi/megaraid/megaraid_sas_base.c
drivers/scsi/megaraid/megaraid_sas_fusion.c