wl1271: Move work-init calls to hw allocation
Due to legacy reason, dating back to when the wl1251 and wl1271 still were
a unified driver, some work-structures are initialized on hardware startup.
The hardware recovery code creates a scenario in which it is possible for a
workstruct to be re-initialized while the work-function itself is running,
which causes a kernel WARNing and a subsequent reboot.
To remedy this, move the work initialization calls to the hw allocation,
which is the logically correct place for them anyway.
Signed-off-by: Juuso Oikarinen <juuso.oikarinen@nokia.com>
Tested-by: Tuomas Katila <ext-tuomas.2.katila@nokia.com>
Reviewed-by: Luciano Coelho <luciano.coelho@nokia.com>
Signed-off-by: Luciano Coelho <luciano.coelho@nokia.com>