platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table
authorJan Kiszka <jan.kiszka@siemens.com>
Wed, 4 Sep 2019 06:42:30 +0000 (08:42 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sun, 10 Nov 2019 10:27:55 +0000 (11:27 +0100)
commit06e8438eddf87122fb32a3d0a940237a5678cad2
tree7d23f2cf1082e00fc00dacd4614df9cf05801412
parent2d830cf287a59a7569a6fe27d5d05d5e3148c757
platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table

commit ad0d315b4d4e7138f43acf03308192ec00e9614d upstream.

The SIMATIC IPC227E uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this device
to the critical systems list.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/platform/x86/pmc_atom.c