X-Git-Url: http://review.tizen.org/git/?a=blobdiff_plain;f=build.cmd;h=be6b2a7fde34fb0438cd5f4800339fe3042e36ea;hb=d424bb734ce61bc98d1cfab815c48c5ad1d01d5e;hp=15e7cf36bb1655f8c393df4fd1f0b57e9bb289a3;hpb=d135144e76d15054d62b996e218694c19fdab9de;p=platform%2Fupstream%2Fcoreclr.git diff --git a/build.cmd b/build.cmd index 15e7cf3..be6b2a7 100644 --- a/build.cmd +++ b/build.cmd @@ -9,59 +9,8 @@ echo %__MsgPrefix%Starting Build at %TIME% set __ThisScriptFull="%~f0" set __ThisScriptDir="%~dp0" -:: Default to highest Visual Studio version available -:: -:: For VS2015 (and prior), only a single instance is allowed to be installed on a box -:: and VS140COMNTOOLS is set as a global environment variable by the installer. This -:: allows users to locate where the instance of VS2015 is installed. -:: -:: For VS2017, multiple instances can be installed on the same box SxS and VS150COMNTOOLS -:: is no longer set as a global environment variable and is instead only set if the user -:: has launched the VS2017 Developer Command Prompt. -:: -:: Following this logic, we will default to the VS2017 toolset if VS150COMNTOOLS tools is -:: set, as this indicates the user is running from the VS2017 Developer Command Prompt and -:: is already configured to use that toolset. Otherwise, we will fallback to using the VS2015 -:: toolset if it is installed. Finally, we will fail the script if no supported VS instance -:: can be found. - -if defined VisualStudioVersion ( - if not defined __VSVersion echo %__MsgPrefix%Detected Visual Studio %VisualStudioVersion% developer command ^prompt environment - goto :Run -) - -echo %__MsgPrefix%Searching ^for Visual Studio 2017 or 2015 installation -set _VSWHERE="%ProgramFiles(x86)%\Microsoft Visual Studio\Installer\vswhere.exe" -if exist %_VSWHERE% ( -for /f "usebackq tokens=*" %%i in (`%_VSWHERE% -latest -prerelease -property installationPath`) do set _VSCOMNTOOLS=%%i\Common7\Tools -) -if not exist "%_VSCOMNTOOLS%" set _VSCOMNTOOLS=%VS140COMNTOOLS% -if not exist "%_VSCOMNTOOLS%" ( - echo %__MsgPrefix%Error: Visual Studio 2015 or 2017 required. - echo Please see https://github.com/dotnet/corefx/blob/master/Documentation/project-docs/developer-guide.md for build instructions. - exit /b 1 -) - -call "%_VSCOMNTOOLS%\VsDevCmd.bat" - -:Run - -REM Make the work-around to a bug in the microsoft.dotnet.buildtools.coreclr package until it is fixed. -reg query HKEY_CLASSES_ROOT\WOW6432Node\CLSID\{3BFCEA48-620F-4B6B-81F7-B9AF75454C7D}\InprocServer32 > NUL: 2>&1 -if NOT '%ERRORLEVEL%' == '0' ( - echo. - echo.********************************************************************************** - echo.Error: We have detected that the msdia120.dll is not registered. - echo.This is necessary for the build to complete without a Class_Not_Registered error. - echo. - echo.You can fix this by - echo. 1. Launching the "Developer Command Prompt for VS2017" with Administrative privileges - echo. 2. Running regsvr32.exe "%%VSINSTALLDIR%%\Common7\IDE\msdia120.dll" - echo. - echo.This will only need to be done once for the lifetime of the machine. - echo.For more details see: https://github.com/dotnet/coreclr/issues/11305 - exit /b 1 -) +call "%__ThisScriptDir%"\setup_vs_tools.cmd +if NOT '%ERRORLEVEL%' == '0' exit /b 1 if defined VS150COMNTOOLS ( set "__VSToolsRoot=%VS150COMNTOOLS%" @@ -73,6 +22,11 @@ if defined VS150COMNTOOLS ( set __VSVersion=vs2015 ) +:: Work around Jenkins CI + msbuild problem: Jenkins sometimes creates very large environment +:: variables, and msbuild can't handle environment blocks with such large variables. So clear +:: out the variables that might be too large. +set ghprbCommentBody= + :: Note that the msbuild project files (specifically, dir.proj) will use the following variables, if set: :: __BuildArch -- default: x64 :: __BuildType -- default: Debug @@ -139,6 +93,7 @@ set __BuildTests=1 set __BuildPackages=1 set __BuildNativeCoreLib=1 set __RestoreOptData=1 +set __GenerateLayout=0 set __CrossgenAltJit= @REM CMD has a nasty habit of eating "=" on the argument list, so passing: @@ -209,9 +164,6 @@ if /i "%1" == "-ibcinstrument" (set __IbcTuning=/Tuning&set processedArgs= if /i "%1" == "-toolset_dir" (set __ToolsetDir=%2&set __PassThroughArgs=%__PassThroughArgs% %2&set processedArgs=!processedArgs! %1 %2&shift&shift&goto Arg_Loop) if /i "%1" == "-crossgenaltjit" (set __CrossgenAltJit=%2&set processedArgs=!processedArgs! %1 %2&shift&shift&goto Arg_Loop) -REM Temporarily eat old -altjitcrossgen flag until CI system is updated. -if /i "%1" == "-altjitcrossgen" (set processedArgs=!processedArgs! %1&shift&goto Arg_Loop) - REM TODO these are deprecated remove them eventually REM don't add more, use the - syntax instead if /i "%1" == "freebsdmscorlib" (set __BuildSOS=0&set __BuildNativeCoreLib=0&set __BuildNative=0&set __BuildTests=0&set __BuildPackages=0&set __BuildOS=FreeBSD&set __SkipNugetPackage=1&set processedArgs=!processedArgs! %1&shift&goto Arg_Loop) @@ -227,6 +179,7 @@ if /i "%1" == "skipnative" (set __BuildNative=0&set processedArgs=!proc if /i "%1" == "skiptests" (set __BuildTests=0&set processedArgs=!processedArgs! %1&shift&goto Arg_Loop) if /i "%1" == "skipbuildpackages" (set __BuildPackages=0&set processedArgs=!processedArgs! %1&shift&goto Arg_Loop) if /i "%1" == "skiprestoreoptdata" (set __RestoreOptData=0&set processedArgs=!processedArgs! %1&shift&goto Arg_Loop) +if /i "%1" == "generatelayout" (set __GenerateLayout=1&set processedArgs=!processedArgs! %1&shift&goto Arg_Loop) if /i "%1" == "usenmakemakefiles" (set __NMakeMakefiles=1&set __ConfigureOnly=1&set __BuildNative=1&set __BuildNativeCoreLib=0&set __BuildCoreLib=0&set __BuildTests=0&set __BuildPackages=0&set processedArgs=!processedArgs! %1&shift&goto Arg_Loop) if /i "%1" == "pgoinstrument" (set __PgoInstrument=1&set processedArgs=!processedArgs! %1&shift&goto Arg_Loop) if /i "%1" == "nopgooptimize" (set __PgoOptimize=0&set processedArgs=!processedArgs! %1&shift&goto Arg_Loop) @@ -297,6 +250,16 @@ if %__EnforcePgo%==1 ( ) ) +REM Determine if this is a cross-arch build + +if /i "%__BuildArch%"=="arm64" ( + set __DoCrossArchBuild=1 + ) + +if /i "%__BuildArch%"=="arm" ( + set __DoCrossArchBuild=1 + ) + :: Set the remaining variables based upon the determined build configuration set "__BinDir=%__RootBinDir%\Product\%__BuildOS%.%__BuildArch%.%__BuildType%" set "__IntermediatesDir=%__RootBinDir%\obj\%__BuildOS%.%__BuildArch%.%__BuildType%" @@ -362,7 +325,7 @@ REM ============================================================================ if %__RestoreOptData% EQU 1 if %__BuildTypeRelease% EQU 1 ( echo %__MsgPrefix%Restoring the OptimizationData Package - @call %__ProjectDir%\run.cmd sync -optdata + @call %__ProjectDir%\run.cmd build -optdata %__RunArgs% %__UnprocessedBuildArgs% if not !errorlevel! == 0 ( echo %__MsgPrefix%Error: Failed to restore the optimization data package. exit /b 1 @@ -385,6 +348,56 @@ for /f "tokens=*" %%s in ('%DotNetCli% msbuild "%OptDataProjectFilePath%" /t:Dum REM ========================================================================================= REM === +REM === Generate source files for eventing +REM === +REM ========================================================================================= + +set __IntermediatesIncDir=%__IntermediatesDir%\src\inc +set __IntermediatesEventingDir=%__IntermediatesDir%\eventing + +REM Find python and set it to the variable PYTHON +echo import sys; sys.stdout.write(sys.executable) | (py -3 || py -2 || python3 || python2 || python) > %TEMP%\pythonlocation.txt 2> NUL +set /p PYTHON=<%TEMP%\pythonlocation.txt + +if /i "%__BuildNative%"=="1" ( + if NOT DEFINED PYTHON ( + echo %__MsgPrefix%Error: Could not find a python installation + exit /b 1 + ) + + echo %__MsgPrefix%Laying out dynamically generated files consumed by the native build system + echo %__MsgPrefix%Laying out dynamically generated Event test files and etmdummy stub functions + "!PYTHON!" -B -Wall %__SourceDir%\scripts\genEventing.py --inc %__IntermediatesIncDir% --dummy %__IntermediatesIncDir%\etmdummy.h --man %__SourceDir%\vm\ClrEtwAll.man --nonextern --noxplatheader|| exit /b 1 + + echo %__MsgPrefix%Laying out dynamically generated EventPipe Implementation + "!PYTHON!" -B -Wall %__SourceDir%\scripts\genEventPipe.py --man %__SourceDir%\vm\ClrEtwAll.man --intermediate %__IntermediatesEventingDir%\eventpipe --nonextern || exit /b 1 + + echo %__MsgPrefix%Laying out ETW event logging interface + "!PYTHON!" -B -Wall %__SourceDir%\scripts\genEtwProvider.py --man %__SourceDir%\vm\ClrEtwAll.man --intermediate %__IntermediatesIncDir% --exc %__SourceDir%\vm\ClrEtwAllMeta.lst || exit /b 1 +) + +if /i "%__DoCrossArchBuild%"=="1" ( + if NOT DEFINED PYTHON ( + echo %__MsgPrefix%Error: Could not find a python installation + exit /b 1 + ) + + set __CrossCompIntermediatesIncDir=%__CrossCompIntermediatesDir%\src\inc + set __CrossCompIntermediatesEventingDir=%__CrossCompIntermediatesDir%\eventing + + echo %__MsgPrefix%Laying out dynamically generated files consumed by the crossarch build system + echo %__MsgPrefix%Laying out dynamically generated Event test files and etmdummy stub functions + "!PYTHON!" -B -Wall %__SourceDir%\scripts\genEventing.py --inc !__CrossCompIntermediatesIncDir! --dummy !__CrossCompIntermediatesIncDir!\etmdummy.h --man %__SourceDir%\vm\ClrEtwAll.man --nonextern || exit /b 1 + + echo %__MsgPrefix%Laying out dynamically generated EventPipe Implementation + "!PYTHON!" -B -Wall %__SourceDir%\scripts\genEventPipe.py --man %__SourceDir%\vm\ClrEtwAll.man --intermediate !__CrossCompIntermediatesEventingDir!\eventpipe --nonextern || exit /b 1 + + echo %__MsgPrefix%Laying out ETW event logging interface + "!PYTHON!" -B -Wall %__SourceDir%\scripts\genEtwProvider.py --man %__SourceDir%\vm\ClrEtwAll.man --intermediate !__CrossCompIntermediatesIncDir! --exc %__SourceDir%\vm\ClrEtwAllMeta.lst || exit /b 1 +) + +REM ========================================================================================= +REM === REM === Build the CLR VM REM === REM ========================================================================================= @@ -479,14 +492,6 @@ REM === Build Cross-Architecture Native Components (if applicable) REM === REM ========================================================================================= -if /i "%__BuildArch%"=="arm64" ( - set __DoCrossArchBuild=1 - ) - -if /i "%__BuildArch%"=="arm" ( - set __DoCrossArchBuild=1 - ) - if /i "%__DoCrossArchBuild%"=="1" ( REM Scope environment changes start { setlocal @@ -724,6 +729,23 @@ if %__BuildTests% EQU 1 ( REM buildtest.cmd has already emitted an error message and mentioned the build log file to examine. exit /b 1 ) +) else if %__GenerateLayout% EQU 1 ( + echo %__MsgPrefix%Generating layout for %__BuildOS%.%__BuildArch%.%__BuildType% + + REM Construct the arguments to pass to the runtest build script. + + rem arm64 builds currently use private toolset which has not been released yet + REM TODO, remove once the toolset is open. + if not "%__ToolsetDir%" == "" call :PrivateToolSet + + set NEXTCMD=call %__ProjectDir%\test\runtest.cmd %__BuildArch% %__BuildType% GenerateLayoutOnly %__UnprocessedBuildArgs% + echo %__MsgPrefix%!NEXTCMD! + !NEXTCMD! + + if not !errorlevel! == 0 ( + REM runtest.cmd has already emitted an error message and mentioned the build log file to examine. + exit /b 1 + ) ) REM =========================================================================================