Merge https://gitlab.denx.de/u-boot/custodians/u-boot-spi into next
[platform/kernel/u-boot.git] / common / Kconfig
index bd35de3..7872bc4 100644 (file)
@@ -647,28 +647,12 @@ config LOG
          discarded if not needed. Logging supports various categories and
          levels of severity.
 
-config SPL_LOG
-       bool "Enable logging support in SPL"
-       depends on LOG
-       help
-         This enables support for logging of status and debug messages. These
-         can be displayed on the console, recorded in a memory buffer, or
-         discarded if not needed. Logging supports various categories and
-         levels of severity.
-
-config TPL_LOG
-       bool "Enable logging support in TPL"
-       depends on LOG
-       help
-         This enables support for logging of status and debug messages. These
-         can be displayed on the console, recorded in a memory buffer, or
-         discarded if not needed. Logging supports various categories and
-         levels of severity.
+if LOG
 
 config LOG_MAX_LEVEL
        int "Maximum log level to record"
-       depends on LOG
-       default 5
+       default 6
+       range 0 9
        help
          This selects the maximum log level that will be recorded. Any value
          higher than this will be ignored. If possible log statements below
@@ -685,14 +669,15 @@ config LOG_MAX_LEVEL
            8 - debug content
            9 - debug hardware I/O
 
-config SPL_LOG_MAX_LEVEL
-       int "Maximum log level to record in SPL"
-       depends on SPL_LOG
-       default 3
+config LOG_DEFAULT_LEVEL
+       int "Default logging level to display"
+       default LOG_MAX_LEVEL
+       range 0 LOG_MAX_LEVEL
        help
-         This selects the maximum log level that will be recorded. Any value
-         higher than this will be ignored. If possible log statements below
-         this level will be discarded at build time. Levels:
+         This is the default logging level set when U-Boot starts. It can
+         be adjusted later using the 'log level' command. Note that setting
+         this to a value above LOG_MAX_LEVEL will be ineffective, since the
+         higher levels are not compiled in to U-Boot.
 
            0 - emergency
            1 - alert
@@ -705,10 +690,38 @@ config SPL_LOG_MAX_LEVEL
            8 - debug content
            9 - debug hardware I/O
 
-config TPL_LOG_MAX_LEVEL
-       int "Maximum log level to record in TPL"
-       depends on TPL_LOG
+config LOG_CONSOLE
+       bool "Allow log output to the console"
+       default y
+       help
+         Enables a log driver which writes log records to the console.
+         Generally the console is the serial port or LCD display. Only the
+         log message is shown - other details like level, category, file and
+         line number are omitted.
+
+config LOG_SYSLOG
+       bool "Log output to syslog server"
+       depends on NET
+       help
+         Enables a log driver which broadcasts log records via UDP port 514
+         to syslog servers.
+
+config SPL_LOG
+       bool "Enable logging support in SPL"
+       depends on LOG
+       help
+         This enables support for logging of status and debug messages. These
+         can be displayed on the console, recorded in a memory buffer, or
+         discarded if not needed. Logging supports various categories and
+         levels of severity.
+
+if SPL_LOG
+
+config SPL_LOG_MAX_LEVEL
+       int "Maximum log level to record in SPL"
+       depends on SPL_LOG
        default 3
+       range 0 9
        help
          This selects the maximum log level that will be recorded. Any value
          higher than this will be ignored. If possible log statements below
@@ -725,14 +738,37 @@ config TPL_LOG_MAX_LEVEL
            8 - debug content
            9 - debug hardware I/O
 
-config LOG_DEFAULT_LEVEL
-       int "Default logging level to display"
-       default 6
+config SPL_LOG_CONSOLE
+       bool "Allow log output to the console in SPL"
+       default y
        help
-         This is the default logging level set when U-Boot starts. It can
-         be adjusted later using the 'log level' command. Note that setting
-         this to a value above LOG_MAX_LEVEL will be ineffective, since the
-         higher levels are not compiled in to U-Boot.
+         Enables a log driver which writes log records to the console.
+         Generally the console is the serial port or LCD display. Only the
+         log message is shown - other details like level, category, file and
+         line number are omitted.
+
+endif
+
+config TPL_LOG
+       bool "Enable logging support in TPL"
+       depends on LOG
+       help
+         This enables support for logging of status and debug messages. These
+         can be displayed on the console, recorded in a memory buffer, or
+         discarded if not needed. Logging supports various categories and
+         levels of severity.
+
+if TPL_LOG
+
+config TPL_LOG_MAX_LEVEL
+       int "Maximum log level to record in TPL"
+       depends on TPL_LOG
+       default 3
+       range 0 9
+       help
+         This selects the maximum log level that will be recorded. Any value
+         higher than this will be ignored. If possible log statements below
+         this level will be discarded at build time. Levels:
 
            0 - emergency
            1 - alert
@@ -745,29 +781,8 @@ config LOG_DEFAULT_LEVEL
            8 - debug content
            9 - debug hardware I/O
 
-config LOG_CONSOLE
-       bool "Allow log output to the console"
-       depends on LOG
-       default y
-       help
-         Enables a log driver which writes log records to the console.
-         Generally the console is the serial port or LCD display. Only the
-         log message is shown - other details like level, category, file and
-         line number are omitted.
-
-config SPL_LOG_CONSOLE
-       bool "Allow log output to the console in SPL"
-       depends on SPL_LOG
-       default y
-       help
-         Enables a log driver which writes log records to the console.
-         Generally the console is the serial port or LCD display. Only the
-         log message is shown - other details like level, category, file and
-         line number are omitted.
-
 config TPL_LOG_CONSOLE
        bool "Allow log output to the console in TPL"
-       depends on TPL_LOG
        default y
        help
          Enables a log driver which writes log records to the console.
@@ -775,19 +790,10 @@ config TPL_LOG_CONSOLE
          log message is shown - other details like level, category, file and
          line number are omitted.
 
-config LOG_TEST
-       bool "Provide a test for logging"
-       depends on LOG
-       default y if SANDBOX
-       help
-         This enables a 'log test' command to test logging. It is normally
-         executed from a pytest and simply outputs logging information
-         in various different ways to test that the logging system works
-         correctly with various settings.
+endif
 
 config LOG_ERROR_RETURN
        bool "Log all functions which return an error"
-       depends on LOG
        help
          When an error is returned in U-Boot it is sometimes difficult to
          figure out the root cause. For example, reading from SPI flash may
@@ -798,6 +804,18 @@ config LOG_ERROR_RETURN
 
          You can add log_ret() to all functions which return an error code.
 
+config LOG_TEST
+       bool "Provide a test for logging"
+       depends on UNIT_TEST
+       default y if SANDBOX
+       help
+         This enables a 'log test' command to test logging. It is normally
+         executed from a pytest and simply outputs logging information
+         in various different ways to test that the logging system works
+         correctly with various settings.
+
+endif
+
 endmenu
 
 config SUPPORT_RAW_INITRD
@@ -925,6 +943,16 @@ config LAST_STAGE_INIT
          U-Boot calls last_stage_init() before the command-line interpreter is
          started.
 
+config PCI_INIT_R
+       bool "Enumerate PCI buses during init"
+       depends on PCI
+       default y if !DM_PCI
+       help
+         With this option U-Boot will call pci_init() soon after relocation,
+         which will enumerate PCI buses. This is needed, for instance, in the
+         case of DM PCI-based Ethernet devices, which will not be detected
+         without having the enumeration performed earlier.
+
 endmenu
 
 menu "Security support"
@@ -1046,3 +1074,21 @@ config BLOBLIST_ADDR
 endmenu
 
 source "common/spl/Kconfig"
+
+config IMAGE_SIGN_INFO
+       bool
+       select SHA1
+       select SHA256
+       help
+         Enable image_sign_info helper functions.
+
+if IMAGE_SIGN_INFO
+
+config SPL_IMAGE_SIGN_INFO
+       bool
+       select SHA1
+       select SHA256
+       help
+         Enable image_sign_info helper functions in SPL.
+
+endif