Enables an 'i2c edid' command which can read EDID
information over I2C from an attached LCD display.
-- Splash Screen Support: CONFIG_SPLASH_SCREEN
-
- If this option is set, the environment is checked for
- a variable "splashimage". If found, the usual display
- of logo, copyright and system information on the LCD
- is suppressed and the BMP image at the address
- specified in "splashimage" is loaded instead. The
- console is redirected to the "nulldev", too. This
- allows for a "silent" boot where a splash screen is
- loaded very quickly after power-on.
-
- CONFIG_SPLASHIMAGE_GUARD
-
- If this option is set, then U-Boot will prevent the environment
- variable "splashimage" from being set to a problematic address
- (see doc/README.displaying-bmps).
- This option is useful for targets where, due to alignment
- restrictions, an improperly aligned BMP image will cause a data
- abort. If you think you will not have problems with unaligned
- accesses (for example because your toolchain prevents them)
- there is no need to set this option.
-
- CONFIG_SPLASH_SCREEN_ALIGN
-
- If this option is set the splash image can be freely positioned
- on the screen. Environment variable "splashpos" specifies the
- position as "x,y". If a positive number is given it is used as
- number of pixel from left/top. If a negative number is given it
- is used as number of pixel from right/bottom. You can also
- specify 'm' for centering the image.
-
- Example:
- setenv splashpos m,m
- => image at center of screen
-
- setenv splashpos 30,20
- => image at x = 30 and y = 20
-
- setenv splashpos -10,m
- => vertically centered image
- at x = dspWidth - bmpWidth - 9
-
- Gzip compressed BMP image support: CONFIG_VIDEO_BMP_GZIP
If this option is set, additionally to standard BMP
CONFIG_BOOTP_NISDOMAIN
CONFIG_BOOTP_BOOTFILESIZE
- CONFIG_BOOTP_SEND_HOSTNAME
CONFIG_BOOTP_NTPSERVER
CONFIG_BOOTP_TIMEOFFSET
CONFIG_BOOTP_VENDOREX
to Link-local IP address configuration if the DHCP server
is not available.
- CONFIG_BOOTP_SEND_HOSTNAME - Some DHCP servers are capable
- to do a dynamic update of a DNS server. To do this, they
- need the hostname of the DHCP requester.
- If CONFIG_BOOTP_SEND_HOSTNAME is defined, the content
- of the "hostname" environment variable is passed as
- option 12 to the DHCP server.
-
CONFIG_BOOTP_DHCP_REQUEST_DELAY
A 32bit value in microseconds for a delay between
parameters from when MMC is being used in raw mode
(for falcon mode)
- CONFIG_SYS_MMCSD_FS_BOOT_PARTITION
- Partition on the MMC to load U-Boot from when the MMC is being
- used in fs mode
-
CONFIG_SPL_FS_LOAD_PAYLOAD_NAME
Filename to read to load U-Boot when reading from filesystem
CONFIG_SPL_SKIP_RELOCATE
Avoid SPL relocation
- CONFIG_SPL_NAND_BASE
- Include nand_base.c in the SPL. Requires
- CONFIG_SPL_NAND_DRIVERS.
-
- CONFIG_SPL_NAND_DRIVERS
- SPL uses normal NAND drivers, not minimal drivers.
-
CONFIG_SPL_NAND_IDENT
SPL uses the chip ID list to identify the NAND flash.
Requires CONFIG_SPL_NAND_BASE.
- CONFIG_SPL_NAND_ECC
- Include standard software ECC in the SPL
-
- CONFIG_SPL_NAND_SIMPLE
- Support for NAND boot using simple NAND drivers that
- expose the cmd_ctrl() interface.
-
CONFIG_SPL_UBI
Support for a lightweight UBI (fastmap) scanner and
loader
downloads succeed with high packet loss rates, or with
unreliable TFTP servers or client hardware.
+ tftpwindowsize - if this is set, the value is used for TFTP's
+ window size as described by RFC 7440.
+ This means the count of blocks we can receive before
+ sending ack to server.
+
vlan - When set to a value < 4095 the traffic over
Ethernet is encapsulated/received over 802.1q
VLAN tagged frames.