- * @exception E_INVALID_ARG Either the length of the specified string for a section
- * or an entry is less than or equal to @c 0,
- * or a @c null value is passed. @n
- * Note that, it is also possible that the data inside a registry instance is
- * corrupted due to its usage in a multi-threaded environment without
- * synchronization.
- * @exception E_SECTION_NOT_FOUND The specified @c sectionName is not found within the registry.
- * @exception E_KEY_NOT_FOUND The specified @c entryName is not found within the registry.
- * @exception E_PARSING_FAILED The method has failed to parse the encoded entry value string, or the value is retrieved by using an incorrect data type.
- * @exception E_DATA_NOT_FOUND The name-value pair has no value assigned (if the value is retrieved using the REGTYPE_STRING type, an empty string is returned even if no value is assigned).
- * @remarks The ByteBuffer should be constructed before passing it to the method.
- * That is, the size of the binary data to be fetched should be decided beforehand.
- * When the %ByteBuffer capacity is less than the actual binary data stored in the registry,
- * this method reads the data as much as the %ByteBuffer capacity. The position of the %ByteBuffer and
- * limit are not changed. When the %ByteBuffer capacity is greater than the actual data size,
+ * @exception E_INVALID_ARG The length of the specified section name or entry name is less than or equal to @c 0.
+ * @exception E_SECTION_NOT_FOUND The specified @c sectionName is not found in the registry.
+ * @exception E_KEY_NOT_FOUND The specified @c entryName is not found in the registry.
+ * @exception E_PARSING_FAILED Either of the following conditions has occurred:
+ * - The method has failed to parse the encoded entry value string.
+ * - The specified data type of the value and the data type of the retrieved value are different.
+ * @exception E_DATA_NOT_FOUND There is no value assigned for the specified entry name. @n
+ * If the value is retrieved using the REGTYPE_STRING type,
+ * an empty string is returned even if no value is assigned.
+ * @remarks Decide the size of the byte data to be fecthed and construct the Tizen::Base::ByteBuffer before passing it to the method. @n
+ * When the %Tizen::Base::ByteBuffer capacity is less than the actual binary data stored in the registry,
+ * this method reads data that fits the %Tizen::Base::ByteBuffer capacity. The position of the %Tizen::Base::ByteBuffer and
+ * limit are not changed. @n
+ * When the %Tizen::Base::ByteBuffer capacity is greater than the actual data size,