[Pass] pass_support=1 pass_gov_type=1 pass_num_scenario_levels=4 pass_init_scenario_level=0 #################################################### ### Scenario Level for PMQoS and Thermal Monitor ### #################################################### [ScenarioLevel0] limit_min_freq=449000 limit_max_freq=1144000 limit_min_cpu=0 limit_max_cpu=2 [ScenarioLevel1] limit_min_freq=1144000 limit_max_freq=1144000 limit_min_cpu=2 limit_max_cpu=2 [ScenarioLevel2] limit_min_freq=449000 limit_max_freq=449000 limit_min_cpu=0 limit_max_cpu=1 [ScenarioLevel3] limit_min_freq=449000 limit_max_freq=1014000 ######################### ### Scenario of PMQoS ### ######################### [PassScenario] pass_scenario_support=yes pass_num_scenarios=3 [Scenario0] name=AppLaunch support=yes scenario_level=1 [Scenario1] name=UltraPowerSaving support=yes scenario_level=2 [Scenario2] name=Doze support=yes scenario_level=3 ################################### ### Scenario of Thermal Monitor ### ################################### # Following action name are defiend on Tizen platform. # The 'temperature' of thermal.scenario must be defined in descending order. # If you change the following name, doesn't guarantee the compatibility. # - Release, Warning, LimitAction, Shutdown [thermal] thermal_support=yes thermal_number_of_scenario=4 thermal_timer_interval_ms=10000 [thermal.scenario0] support=yes name=Release temperature=44 timer_interval_ms=10000 scenario_level=0 [thermal.scenario1] support=yes name=Warning temperature=46 timer_interval_ms=5000 [thermal.scenario2] support=yes name=LimitAction temperature=48 timer_interval_ms=3000 [thermal.scenario3] support=yes name=Shutdown temperature=53 timer_interval_ms=1000