Merge pull request #14717 from CarolEidt/Fix14624
[platform/upstream/coreclr.git] / run.cmd
1 @if not defined _echo @echo off
2 setlocal
3
4 :: Default to highest Visual Studio version available
5 ::
6 :: For VS2015 (and prior), only a single instance is allowed to be installed on a box
7 :: and VS140COMNTOOLS is set as a global environment variable by the installer. This
8 :: allows users to locate where the instance of VS2015 is installed.
9 ::
10 :: For VS2017, multiple instances can be installed on the same box SxS and VS150COMNTOOLS
11 :: is no longer set as a global environment variable and is instead only set if the user
12 :: has launched the VS2017 Developer Command Prompt.
13 ::
14 :: Following this logic, we will default to the VS2017 toolset if VS150COMNTOOLS tools is
15 :: set, as this indicates the user is running from the VS2017 Developer Command Prompt and
16 :: is already configured to use that toolset. Otherwise, we will fallback to using the VS2015
17 :: toolset if it is installed. Finally, we will fail the script if no supported VS instance
18 :: can be found.
19 if defined VisualStudioVersion (
20     if not defined __VSVersion echo %__MsgPrefix%Detected Visual Studio %VisualStudioVersion% developer command ^prompt environment
21     goto :Run
22 )
23
24 set _VSWHERE="%ProgramFiles(x86)%\Microsoft Visual Studio\Installer\vswhere.exe"
25 if exist %_VSWHERE% (
26   for /f "usebackq tokens=*" %%i in (`%_VSWHERE% -latest -prerelease -property installationPath`) do set _VSCOMNTOOLS=%%i\Common7\Tools
27 )
28 if not exist "%_VSCOMNTOOLS%" set _VSCOMNTOOLS=%VS140COMNTOOLS%
29 if not exist "%_VSCOMNTOOLS%" (
30   echo %__MsgPrefix%Error: Visual Studio 2015 or 2017 required.
31   echo        Please see https://github.com/dotnet/corefx/blob/master/Documentation/project-docs/developer-guide.md for build instructions.
32   exit /b 1
33 )
34
35 call "%_VSCOMNTOOLS%\VsDevCmd.bat"
36
37 :Run
38 :: Clear the 'Platform' env variable for this session, as it's a per-project setting within the build, and
39 :: misleading value (such as 'MCD' in HP PCs) may lead to build breakage (issue: #69).
40 set Platform=
41
42 :: Restore the Tools directory
43 call %~dp0init-tools.cmd
44 if NOT [%ERRORLEVEL%]==[0] (
45   exit /b 1
46 )
47
48 set _toolRuntime=%~dp0Tools
49 set _dotnet=%_toolRuntime%\dotnetcli\dotnet.exe
50 set _json=%~dp0config.json
51
52 :: run.exe depends on running in the root directory, notably because the config.json specifies
53 :: a relative path to the binclash logger
54
55 pushd %~dp0
56 echo Running: %_dotnet% %_toolRuntime%\run.exe %~dp0config.json %*
57 call %_dotnet% %_toolRuntime%\run.exe "%_json%" %*
58 popd
59 if NOT [%ERRORLEVEL%]==[0] (
60   exit /b 1
61 )
62
63 exit /b 0