Merge tag 'mips_6.3_1' of git://git.kernel.org/pub/scm/linux/kernel/git/mips/linux
[platform/kernel/linux-rpi.git] / kernel / time / Kconfig
1 # SPDX-License-Identifier: GPL-2.0-only
2 #
3 # Timer subsystem related configuration options
4 #
5
6 # Options selectable by arch Kconfig
7
8 # Watchdog function for clocksources to detect instabilities
9 config CLOCKSOURCE_WATCHDOG
10         bool
11
12 # Architecture has extra clocksource data
13 config ARCH_CLOCKSOURCE_DATA
14         bool
15
16 # Architecture has extra clocksource init called from registration
17 config ARCH_CLOCKSOURCE_INIT
18         bool
19
20 # Clocksources require validation of the clocksource against the last
21 # cycle update - x86/TSC misfeature
22 config CLOCKSOURCE_VALIDATE_LAST_CYCLE
23         bool
24
25 # Timekeeping vsyscall support
26 config GENERIC_TIME_VSYSCALL
27         bool
28
29 # The generic clock events infrastructure
30 config GENERIC_CLOCKEVENTS
31         def_bool !LEGACY_TIMER_TICK
32
33 # Architecture can handle broadcast in a driver-agnostic way
34 config ARCH_HAS_TICK_BROADCAST
35         bool
36
37 # Clockevents broadcasting infrastructure
38 config GENERIC_CLOCKEVENTS_BROADCAST
39         bool
40         depends on GENERIC_CLOCKEVENTS
41
42 # Automatically adjust the min. reprogramming time for
43 # clock event device
44 config GENERIC_CLOCKEVENTS_MIN_ADJUST
45         bool
46
47 # Generic update of CMOS clock
48 config GENERIC_CMOS_UPDATE
49         bool
50
51 # Select to handle posix CPU timers from task_work
52 # and not from the timer interrupt context
53 config HAVE_POSIX_CPU_TIMERS_TASK_WORK
54         bool
55
56 config POSIX_CPU_TIMERS_TASK_WORK
57         bool
58         default y if POSIX_TIMERS && HAVE_POSIX_CPU_TIMERS_TASK_WORK
59
60 config LEGACY_TIMER_TICK
61         bool
62         help
63           The legacy timer tick helper is used by platforms that
64           lack support for the generic clockevent framework.
65           New platforms should use generic clockevents instead.
66
67 config TIME_KUNIT_TEST
68         tristate "KUnit test for kernel/time functions" if !KUNIT_ALL_TESTS
69         depends on KUNIT
70         default KUNIT_ALL_TESTS
71         help
72           Enable this option to test RTC library functions.
73
74           If unsure, say N.
75
76 config CONTEXT_TRACKING
77         bool
78
79 config CONTEXT_TRACKING_IDLE
80         bool
81         select CONTEXT_TRACKING
82         help
83           Tracks idle state on behalf of RCU.
84
85 if GENERIC_CLOCKEVENTS
86 menu "Timers subsystem"
87
88 # Core internal switch. Selected by NO_HZ_COMMON / HIGH_RES_TIMERS. This is
89 # only related to the tick functionality. Oneshot clockevent devices
90 # are supported independent of this.
91 config TICK_ONESHOT
92         bool
93
94 config NO_HZ_COMMON
95         bool
96         select TICK_ONESHOT
97
98 choice
99         prompt "Timer tick handling"
100         default NO_HZ_IDLE if NO_HZ
101
102 config HZ_PERIODIC
103         bool "Periodic timer ticks (constant rate, no dynticks)"
104         help
105           This option keeps the tick running periodically at a constant
106           rate, even when the CPU doesn't need it.
107
108 config NO_HZ_IDLE
109         bool "Idle dynticks system (tickless idle)"
110         select NO_HZ_COMMON
111         help
112           This option enables a tickless idle system: timer interrupts
113           will only trigger on an as-needed basis when the system is idle.
114           This is usually interesting for energy saving.
115
116           Most of the time you want to say Y here.
117
118 config NO_HZ_FULL
119         bool "Full dynticks system (tickless)"
120         # NO_HZ_COMMON dependency
121         # We need at least one periodic CPU for timekeeping
122         depends on SMP
123         depends on HAVE_CONTEXT_TRACKING_USER
124         # VIRT_CPU_ACCOUNTING_GEN dependency
125         depends on HAVE_VIRT_CPU_ACCOUNTING_GEN
126         select NO_HZ_COMMON
127         select RCU_NOCB_CPU
128         select VIRT_CPU_ACCOUNTING_GEN
129         select IRQ_WORK
130         select CPU_ISOLATION
131         help
132          Adaptively try to shutdown the tick whenever possible, even when
133          the CPU is running tasks. Typically this requires running a single
134          task on the CPU. Chances for running tickless are maximized when
135          the task mostly runs in userspace and has few kernel activity.
136
137          You need to fill up the nohz_full boot parameter with the
138          desired range of dynticks CPUs to use it. This is implemented at
139          the expense of some overhead in user <-> kernel transitions:
140          syscalls, exceptions and interrupts.
141
142          By default, without passing the nohz_full parameter, this behaves just
143          like NO_HZ_IDLE.
144
145          If you're a distro say Y.
146
147 endchoice
148
149 config CONTEXT_TRACKING_USER
150         bool
151         depends on HAVE_CONTEXT_TRACKING_USER
152         select CONTEXT_TRACKING
153         help
154           Track transitions between kernel and user on behalf of RCU and
155           tickless cputime accounting. The former case relies on context
156           tracking to enter/exit RCU extended quiescent states.
157
158 config CONTEXT_TRACKING_USER_FORCE
159         bool "Force user context tracking"
160         depends on CONTEXT_TRACKING_USER
161         default y if !NO_HZ_FULL
162         help
163           The major pre-requirement for full dynticks to work is to
164           support the user context tracking subsystem. But there are also
165           other dependencies to provide in order to make the full
166           dynticks working.
167
168           This option stands for testing when an arch implements the
169           user context tracking backend but doesn't yet fulfill all the
170           requirements to make the full dynticks feature working.
171           Without the full dynticks, there is no way to test the support
172           for user context tracking and the subsystems that rely on it: RCU
173           userspace extended quiescent state and tickless cputime
174           accounting. This option copes with the absence of the full
175           dynticks subsystem by forcing the user context tracking on all
176           CPUs in the system.
177
178           Say Y only if you're working on the development of an
179           architecture backend for the user context tracking.
180
181           Say N otherwise, this option brings an overhead that you
182           don't want in production.
183
184 config NO_HZ
185         bool "Old Idle dynticks config"
186         help
187           This is the old config entry that enables dynticks idle.
188           We keep it around for a little while to enforce backward
189           compatibility with older config files.
190
191 config HIGH_RES_TIMERS
192         bool "High Resolution Timer Support"
193         select TICK_ONESHOT
194         help
195           This option enables high resolution timer support. If your
196           hardware is not capable then this option only increases
197           the size of the kernel image.
198
199 config CLOCKSOURCE_WATCHDOG_MAX_SKEW_US
200         int "Clocksource watchdog maximum allowable skew (in μs)"
201         depends on CLOCKSOURCE_WATCHDOG
202         range 50 1000
203         default 125
204         help
205           Specify the maximum amount of allowable watchdog skew in
206           microseconds before reporting the clocksource to be unstable.
207           The default is based on a half-second clocksource watchdog
208           interval and NTP's maximum frequency drift of 500 parts
209           per million.  If the clocksource is good enough for NTP,
210           it is good enough for the clocksource watchdog!
211
212 endmenu
213 endif