o * ppc.h (ppc_cpu_t): Typedef to uint64_t.
[external/binutils.git] / include / opcode / ppc.h
1 /* ppc.h -- Header file for PowerPC opcode table
2    Copyright 1994, 1995, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006,
3    2007, 2008, 2009 Free Software Foundation, Inc.
4    Written by Ian Lance Taylor, Cygnus Support
5
6 This file is part of GDB, GAS, and the GNU binutils.
7
8 GDB, GAS, and the GNU binutils are free software; you can redistribute
9 them and/or modify them under the terms of the GNU General Public
10 License as published by the Free Software Foundation; either version
11 1, or (at your option) any later version.
12
13 GDB, GAS, and the GNU binutils are distributed in the hope that they
14 will be useful, but WITHOUT ANY WARRANTY; without even the implied
15 warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See
16 the GNU General Public License for more details.
17
18 You should have received a copy of the GNU General Public License
19 along with this file; see the file COPYING.  If not, write to the Free
20 Software Foundation, 51 Franklin Street - Fifth Floor, Boston, MA 02110-1301, USA.  */
21
22 #ifndef PPC_H
23 #define PPC_H
24
25 #include "bfd_stdint.h"
26
27 typedef uint64_t ppc_cpu_t;
28
29 /* The opcode table is an array of struct powerpc_opcode.  */
30
31 struct powerpc_opcode
32 {
33   /* The opcode name.  */
34   const char *name;
35
36   /* The opcode itself.  Those bits which will be filled in with
37      operands are zeroes.  */
38   unsigned long opcode;
39
40   /* The opcode mask.  This is used by the disassembler.  This is a
41      mask containing ones indicating those bits which must match the
42      opcode field, and zeroes indicating those bits which need not
43      match (and are presumably filled in by operands).  */
44   unsigned long mask;
45
46   /* One bit flags for the opcode.  These are used to indicate which
47      specific processors support the instructions.  The defined values
48      are listed below.  */
49   ppc_cpu_t flags;
50
51   /* One bit flags for the opcode.  These are used to indicate which
52      specific processors no longer support the instructions.  The defined
53      values are listed below.  */
54   ppc_cpu_t deprecated;
55
56   /* An array of operand codes.  Each code is an index into the
57      operand table.  They appear in the order which the operands must
58      appear in assembly code, and are terminated by a zero.  */
59   unsigned char operands[8];
60 };
61
62 /* The table itself is sorted by major opcode number, and is otherwise
63    in the order in which the disassembler should consider
64    instructions.  */
65 extern const struct powerpc_opcode powerpc_opcodes[];
66 extern const int powerpc_num_opcodes;
67
68 /* Values defined for the flags field of a struct powerpc_opcode.  */
69
70 /* Opcode is defined for the PowerPC architecture.  */
71 #define PPC_OPCODE_PPC                   1
72
73 /* Opcode is defined for the POWER (RS/6000) architecture.  */
74 #define PPC_OPCODE_POWER                 2
75
76 /* Opcode is defined for the POWER2 (Rios 2) architecture.  */
77 #define PPC_OPCODE_POWER2                4
78
79 /* Opcode is only defined on 32 bit architectures.  */
80 #define PPC_OPCODE_32                    8
81
82 /* Opcode is only defined on 64 bit architectures.  */
83 #define PPC_OPCODE_64                 0x10
84
85 /* Opcode is supported by the Motorola PowerPC 601 processor.  The 601
86    is assumed to support all PowerPC (PPC_OPCODE_PPC) instructions,
87    but it also supports many additional POWER instructions.  */
88 #define PPC_OPCODE_601                0x20
89
90 /* Opcode is supported in both the Power and PowerPC architectures
91    (ie, compiler's -mcpu=common or assembler's -mcom).  */
92 #define PPC_OPCODE_COMMON             0x40
93
94 /* Opcode is supported for any Power or PowerPC platform (this is
95    for the assembler's -many option, and it eliminates duplicates).  */
96 #define PPC_OPCODE_ANY                0x80
97
98 /* Opcode is supported as part of the 64-bit bridge.  */
99 #define PPC_OPCODE_64_BRIDGE         0x100
100
101 /* Opcode is supported by Altivec Vector Unit */
102 #define PPC_OPCODE_ALTIVEC           0x200
103
104 /* Opcode is supported by PowerPC 403 processor.  */
105 #define PPC_OPCODE_403               0x400
106
107 /* Opcode is supported by PowerPC BookE processor.  */
108 #define PPC_OPCODE_BOOKE             0x800
109
110 /* Opcode is only supported by 64-bit PowerPC BookE processor.  */
111 #define PPC_OPCODE_BOOKE64          0x1000
112
113 /* Opcode is supported by PowerPC 440 processor.  */
114 #define PPC_OPCODE_440              0x2000
115
116 /* Opcode is only supported by Power4 architecture.  */
117 #define PPC_OPCODE_POWER4           0x4000
118
119 /* Opcode is only supported by Power7 architecture.  */
120 #define PPC_OPCODE_POWER7           0x8000
121
122 /* Opcode is only supported by POWERPC Classic architecture.  */
123 #define PPC_OPCODE_CLASSIC         0x10000
124
125 /* Opcode is only supported by e500x2 Core.  */
126 #define PPC_OPCODE_SPE             0x20000
127
128 /* Opcode is supported by e500x2 Integer select APU.  */
129 #define PPC_OPCODE_ISEL            0x40000
130
131 /* Opcode is an e500 SPE floating point instruction.  */
132 #define PPC_OPCODE_EFS             0x80000
133
134 /* Opcode is supported by branch locking APU.  */
135 #define PPC_OPCODE_BRLOCK         0x100000
136
137 /* Opcode is supported by performance monitor APU.  */
138 #define PPC_OPCODE_PMR            0x200000
139
140 /* Opcode is supported by cache locking APU.  */
141 #define PPC_OPCODE_CACHELCK       0x400000
142
143 /* Opcode is supported by machine check APU.  */
144 #define PPC_OPCODE_RFMCI          0x800000
145
146 /* Opcode is only supported by Power5 architecture.  */
147 #define PPC_OPCODE_POWER5        0x1000000
148
149 /* Opcode is supported by PowerPC e300 family.  */
150 #define PPC_OPCODE_E300          0x2000000
151
152 /* Opcode is only supported by Power6 architecture.  */
153 #define PPC_OPCODE_POWER6        0x4000000
154
155 /* Opcode is only supported by PowerPC Cell family.  */
156 #define PPC_OPCODE_CELL          0x8000000
157
158 /* Opcode is supported by CPUs with paired singles support.  */
159 #define PPC_OPCODE_PPCPS         0x10000000
160
161 /* Opcode is supported by Power E500MC */
162 #define PPC_OPCODE_E500MC        0x20000000
163
164 /* Opcode is supported by PowerPC 405 processor.  */
165 #define PPC_OPCODE_405           0x40000000
166
167 /* Opcode is supported by Vector-Scalar (VSX) Unit */
168 #define PPC_OPCODE_VSX           0x80000000
169
170 /* Opcode is supported by A2.  */
171 #define PPC_OPCODE_PPCA2         0x100000000ULL
172
173 /* A macro to extract the major opcode from an instruction.  */
174 #define PPC_OP(i) (((i) >> 26) & 0x3f)
175 \f
176 /* The operands table is an array of struct powerpc_operand.  */
177
178 struct powerpc_operand
179 {
180   /* A bitmask of bits in the operand.  */
181   unsigned int bitm;
182
183   /* How far the operand is left shifted in the instruction.
184      -1 to indicate that BITM and SHIFT cannot be used to determine
185      where the operand goes in the insn.  */
186   int shift;
187
188   /* Insertion function.  This is used by the assembler.  To insert an
189      operand value into an instruction, check this field.
190
191      If it is NULL, execute
192          i |= (op & o->bitm) << o->shift;
193      (i is the instruction which we are filling in, o is a pointer to
194      this structure, and op is the operand value).
195
196      If this field is not NULL, then simply call it with the
197      instruction and the operand value.  It will return the new value
198      of the instruction.  If the ERRMSG argument is not NULL, then if
199      the operand value is illegal, *ERRMSG will be set to a warning
200      string (the operand will be inserted in any case).  If the
201      operand value is legal, *ERRMSG will be unchanged (most operands
202      can accept any value).  */
203   unsigned long (*insert)
204     (unsigned long instruction, long op, ppc_cpu_t dialect, const char **errmsg);
205
206   /* Extraction function.  This is used by the disassembler.  To
207      extract this operand type from an instruction, check this field.
208
209      If it is NULL, compute
210          op = (i >> o->shift) & o->bitm;
211          if ((o->flags & PPC_OPERAND_SIGNED) != 0)
212            sign_extend (op);
213      (i is the instruction, o is a pointer to this structure, and op
214      is the result).
215
216      If this field is not NULL, then simply call it with the
217      instruction value.  It will return the value of the operand.  If
218      the INVALID argument is not NULL, *INVALID will be set to
219      non-zero if this operand type can not actually be extracted from
220      this operand (i.e., the instruction does not match).  If the
221      operand is valid, *INVALID will not be changed.  */
222   long (*extract) (unsigned long instruction, ppc_cpu_t dialect, int *invalid);
223
224   /* One bit syntax flags.  */
225   unsigned long flags;
226 };
227
228 /* Elements in the table are retrieved by indexing with values from
229    the operands field of the powerpc_opcodes table.  */
230
231 extern const struct powerpc_operand powerpc_operands[];
232 extern const unsigned int num_powerpc_operands;
233
234 /* Values defined for the flags field of a struct powerpc_operand.  */
235
236 /* This operand takes signed values.  */
237 #define PPC_OPERAND_SIGNED (0x1)
238
239 /* This operand takes signed values, but also accepts a full positive
240    range of values when running in 32 bit mode.  That is, if bits is
241    16, it takes any value from -0x8000 to 0xffff.  In 64 bit mode,
242    this flag is ignored.  */
243 #define PPC_OPERAND_SIGNOPT (0x2)
244
245 /* This operand does not actually exist in the assembler input.  This
246    is used to support extended mnemonics such as mr, for which two
247    operands fields are identical.  The assembler should call the
248    insert function with any op value.  The disassembler should call
249    the extract function, ignore the return value, and check the value
250    placed in the valid argument.  */
251 #define PPC_OPERAND_FAKE (0x4)
252
253 /* The next operand should be wrapped in parentheses rather than
254    separated from this one by a comma.  This is used for the load and
255    store instructions which want their operands to look like
256        reg,displacement(reg)
257    */
258 #define PPC_OPERAND_PARENS (0x8)
259
260 /* This operand may use the symbolic names for the CR fields, which
261    are
262        lt  0    gt  1   eq  2   so  3   un  3
263        cr0 0    cr1 1   cr2 2   cr3 3
264        cr4 4    cr5 5   cr6 6   cr7 7
265    These may be combined arithmetically, as in cr2*4+gt.  These are
266    only supported on the PowerPC, not the POWER.  */
267 #define PPC_OPERAND_CR (0x10)
268
269 /* This operand names a register.  The disassembler uses this to print
270    register names with a leading 'r'.  */
271 #define PPC_OPERAND_GPR (0x20)
272
273 /* Like PPC_OPERAND_GPR, but don't print a leading 'r' for r0.  */
274 #define PPC_OPERAND_GPR_0 (0x40)
275
276 /* This operand names a floating point register.  The disassembler
277    prints these with a leading 'f'.  */
278 #define PPC_OPERAND_FPR (0x80)
279
280 /* This operand is a relative branch displacement.  The disassembler
281    prints these symbolically if possible.  */
282 #define PPC_OPERAND_RELATIVE (0x100)
283
284 /* This operand is an absolute branch address.  The disassembler
285    prints these symbolically if possible.  */
286 #define PPC_OPERAND_ABSOLUTE (0x200)
287
288 /* This operand is optional, and is zero if omitted.  This is used for
289    example, in the optional BF field in the comparison instructions.  The
290    assembler must count the number of operands remaining on the line,
291    and the number of operands remaining for the opcode, and decide
292    whether this operand is present or not.  The disassembler should
293    print this operand out only if it is not zero.  */
294 #define PPC_OPERAND_OPTIONAL (0x400)
295
296 /* This flag is only used with PPC_OPERAND_OPTIONAL.  If this operand
297    is omitted, then for the next operand use this operand value plus
298    1, ignoring the next operand field for the opcode.  This wretched
299    hack is needed because the Power rotate instructions can take
300    either 4 or 5 operands.  The disassembler should print this operand
301    out regardless of the PPC_OPERAND_OPTIONAL field.  */
302 #define PPC_OPERAND_NEXT (0x800)
303
304 /* This operand should be regarded as a negative number for the
305    purposes of overflow checking (i.e., the normal most negative
306    number is disallowed and one more than the normal most positive
307    number is allowed).  This flag will only be set for a signed
308    operand.  */
309 #define PPC_OPERAND_NEGATIVE (0x1000)
310
311 /* This operand names a vector unit register.  The disassembler
312    prints these with a leading 'v'.  */
313 #define PPC_OPERAND_VR (0x2000)
314
315 /* This operand is for the DS field in a DS form instruction.  */
316 #define PPC_OPERAND_DS (0x4000)
317
318 /* This operand is for the DQ field in a DQ form instruction.  */
319 #define PPC_OPERAND_DQ (0x8000)
320
321 /* Valid range of operand is 0..n rather than 0..n-1.  */
322 #define PPC_OPERAND_PLUS1 (0x10000)
323
324 /* Xilinx APU and FSL related operands */
325 #define PPC_OPERAND_FSL (0x20000)
326 #define PPC_OPERAND_FCR (0x40000)
327 #define PPC_OPERAND_UDI (0x80000)
328
329 /* This operand names a vector-scalar unit register.  The disassembler
330    prints these with a leading 'vs'.  */
331 #define PPC_OPERAND_VSR (0x100000)
332 \f
333 /* The POWER and PowerPC assemblers use a few macros.  We keep them
334    with the operands table for simplicity.  The macro table is an
335    array of struct powerpc_macro.  */
336
337 struct powerpc_macro
338 {
339   /* The macro name.  */
340   const char *name;
341
342   /* The number of operands the macro takes.  */
343   unsigned int operands;
344
345   /* One bit flags for the opcode.  These are used to indicate which
346      specific processors support the instructions.  The values are the
347      same as those for the struct powerpc_opcode flags field.  */
348   ppc_cpu_t flags;
349
350   /* A format string to turn the macro into a normal instruction.
351      Each %N in the string is replaced with operand number N (zero
352      based).  */
353   const char *format;
354 };
355
356 extern const struct powerpc_macro powerpc_macros[];
357 extern const int powerpc_num_macros;
358
359 extern ppc_cpu_t ppc_parse_cpu (ppc_cpu_t, const char *);
360
361 #endif /* PPC_H */