1 // SPDX-License-Identifier: GPL-2.0
2 /*
3  * A power allocator to manage temperature
4  *
5  * Copyright (C) 2014 ARM Ltd.
6  *
7  */
8
9 #define pr_fmt(fmt) "Power allocator: " fmt
10
11 #include <linux/rculist.h>
12 #include <linux/slab.h>
13 #include <linux/thermal.h>
14
15 #define CREATE_TRACE_POINTS
16 #include <trace/events/thermal_power_allocator.h>
17
18 #include "thermal_core.h"
19
20 #define INVALID_TRIP -1
21
22 #define FRAC_BITS 10
23 #define int_to_frac(x) ((x) << FRAC_BITS)
24 #define frac_to_int(x) ((x) >> FRAC_BITS)
25
26 /**
27  * mul_frac() - multiply two fixed-point numbers
28  * @x:  first multiplicand
29  * @y:  second multiplicand
30  *
31  * Return: the result of multiplying two fixed-point numbers.  The
32  * result is also a fixed-point number.
33  */
34 static inline s64 mul_frac(s64 x, s64 y)
35 {
36         return (x * y) >> FRAC_BITS;
37 }
38
39 /**
40  * div_frac() - divide two fixed-point numbers
41  * @x:  the dividend
42  * @y:  the divisor
43  *
44  * Return: the result of dividing two fixed-point numbers.  The
45  * result is also a fixed-point number.
46  */
47 static inline s64 div_frac(s64 x, s64 y)
48 {
49         return div_s64(x << FRAC_BITS, y);
50 }
51
52 /**
53  * struct power_allocator_params - parameters for the power allocator governor
54  * @allocated_tzp:      whether we have allocated tzp for this thermal zone and
55  *                      it needs to be freed on unbind
56  * @err_integral:       accumulated error in the PID controller.
57  * @prev_err:   error in the previous iteration of the PID controller.
58  *              Used to calculate the derivative term.
59  * @trip_switch_on:     first passive trip point of the thermal zone.  The
60  *                      governor switches on when this trip point is crossed.
61  *                      If the thermal zone only has one passive trip point,
62  *                      @trip_switch_on should be INVALID_TRIP.
63  * @trip_max_desired_temperature:       last passive trip point of the thermal
64  *                                      zone.  The temperature we are
65  *                                      controlling for.
66  * @sustainable_power:  Sustainable power (heat) that this thermal zone can
67  *                      dissipate
68  */
69 struct power_allocator_params {
70         bool allocated_tzp;
71         s64 err_integral;
72         s32 prev_err;
73         int trip_switch_on;
74         int trip_max_desired_temperature;
75         u32 sustainable_power;
76 };
77
78 /**
79  * estimate_sustainable_power() - Estimate the sustainable power of a thermal zone
80  * @tz: thermal zone we are operating in
81  *
82  * For thermal zones that don't provide a sustainable_power in their
83  * thermal_zone_params, estimate one.  Calculate it using the minimum
84  * power of all the cooling devices as that gives a valid value that
85  * can give some degree of functionality.  For optimal performance of
86  * this governor, provide a sustainable_power in the thermal zone's
87  * thermal_zone_params.
88  */
89 static u32 estimate_sustainable_power(struct thermal_zone_device *tz)
90 {
91         u32 sustainable_power = 0;
92         struct thermal_instance *instance;
93         struct power_allocator_params *params = tz->governor_data;
94
95         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
96                 struct thermal_cooling_device *cdev = instance->cdev;
97                 u32 min_power;
98
99                 if (instance->trip != params->trip_max_desired_temperature)
100                         continue;
101
102                 if (!cdev_is_power_actor(cdev))
103                         continue;
104
105                 if (cdev->ops->state2power(cdev, instance->upper, &min_power))
106                         continue;
107
108                 sustainable_power += min_power;
109         }
110
111         return sustainable_power;
112 }
113
114 /**
115  * estimate_pid_constants() - Estimate the constants for the PID controller
116  * @tz:         thermal zone for which to estimate the constants
117  * @sustainable_power:  sustainable power for the thermal zone
118  * @trip_switch_on:     trip point number for the switch on temperature
119  * @control_temp:       target temperature for the power allocator governor
120  *
121  * This function is used to update the estimation of the PID
122  * controller constants in struct thermal_zone_parameters.
123  */
124 static void estimate_pid_constants(struct thermal_zone_device *tz,
125                                    u32 sustainable_power, int trip_switch_on,
126                                    int control_temp)
127 {
128         int ret;
129         int switch_on_temp;
130         u32 temperature_threshold;
131         s32 k_i;
132
133         ret = tz->ops->get_trip_temp(tz, trip_switch_on, &switch_on_temp);
134         if (ret)
135                 switch_on_temp = 0;
136
137         temperature_threshold = control_temp - switch_on_temp;
138         /*
139          * estimate_pid_constants() tries to find appropriate default
140          * values for thermal zones that don't provide them. If a
141          * system integrator has configured a thermal zone with two
142          * passive trip points at the same temperature, that person
143          * hasn't put any effort to set up the thermal zone properly
144          * so just give up.
145          */
146         if (!temperature_threshold)
147                 return;
148
149         tz->tzp->k_po = int_to_frac(sustainable_power) /
150                 temperature_threshold;
151
152         tz->tzp->k_pu = int_to_frac(2 * sustainable_power) /
153                 temperature_threshold;
154
155         k_i = tz->tzp->k_pu / 10;
156         tz->tzp->k_i = k_i > 0 ? k_i : 1;
157
158         /*
159          * The default for k_d and integral_cutoff is 0, so we can
160          * leave them as they are.
161          */
162 }
163
164 /**
165  * get_sustainable_power() - Get the right sustainable power
166  * @tz:         thermal zone for which to estimate the constants
167  * @params:     parameters for the power allocator governor
168  * @control_temp:       target temperature for the power allocator governor
169  *
170  * This function is used for getting the proper sustainable power value based
171  * on variables which might be updated by the user sysfs interface. If that
172  * happen the new value is going to be estimated and updated. It is also used
173  * after thermal zone binding, where the initial values where set to 0.
174  */
175 static u32 get_sustainable_power(struct thermal_zone_device *tz,
176                                  struct power_allocator_params *params,
177                                  int control_temp)
178 {
179         u32 sustainable_power;
180
181         if (!tz->tzp->sustainable_power)
182                 sustainable_power = estimate_sustainable_power(tz);
183         else
184                 sustainable_power = tz->tzp->sustainable_power;
185
186         /* Check if it's init value 0 or there was update via sysfs */
187         if (sustainable_power != params->sustainable_power) {
188                 estimate_pid_constants(tz, sustainable_power,
189                                        params->trip_switch_on, control_temp);
190
191                 /* Do the estimation only once and make available in sysfs */
192                 tz->tzp->sustainable_power = sustainable_power;
193                 params->sustainable_power = sustainable_power;
194         }
195
196         return sustainable_power;
197 }
198
199 /**
200  * pid_controller() - PID controller
201  * @tz: thermal zone we are operating in
202  * @control_temp:       the target temperature in millicelsius
203  * @max_allocatable_power:      maximum allocatable power for this thermal zone
204  *
205  * This PID controller increases the available power budget so that the
206  * temperature of the thermal zone gets as close as possible to
207  * @control_temp and limits the power if it exceeds it.  k_po is the
208  * proportional term when we are overshooting, k_pu is the
209  * proportional term when we are undershooting.  integral_cutoff is a
210  * threshold below which we stop accumulating the error.  The
211  * accumulated error is only valid if the requested power will make
212  * the system warmer.  If the system is mostly idle, there's no point
213  * in accumulating positive error.
214  *
215  * Return: The power budget for the next period.
216  */
217 static u32 pid_controller(struct thermal_zone_device *tz,
218                           int control_temp,
219                           u32 max_allocatable_power)
220 {
221         s64 p, i, d, power_range;
222         s32 err, max_power_frac;
223         u32 sustainable_power;
224         struct power_allocator_params *params = tz->governor_data;
225
226         max_power_frac = int_to_frac(max_allocatable_power);
227
228         sustainable_power = get_sustainable_power(tz, params, control_temp);
229
230         err = control_temp - tz->temperature;
231         err = int_to_frac(err);
232
233         /* Calculate the proportional term */
234         p = mul_frac(err < 0 ? tz->tzp->k_po : tz->tzp->k_pu, err);
235
236         /*
237          * Calculate the integral term
238          *
239          * if the error is less than cut off allow integration (but
240          * the integral is limited to max power)
241          */
242         i = mul_frac(tz->tzp->k_i, params->err_integral);
243
244         if (err < int_to_frac(tz->tzp->integral_cutoff)) {
245                 s64 i_next = i + mul_frac(tz->tzp->k_i, err);
246
247                 if (abs(i_next) < max_power_frac) {
248                         i = i_next;
249                         params->err_integral += err;
250                 }
251         }
252
253         /*
254          * Calculate the derivative term
255          *
256          * We do err - prev_err, so with a positive k_d, a decreasing
257          * error (i.e. driving closer to the line) results in less
258          * power being applied, slowing down the controller)
259          */
260         d = mul_frac(tz->tzp->k_d, err - params->prev_err);
261         d = div_frac(d, jiffies_to_msecs(tz->passive_delay_jiffies));
262         params->prev_err = err;
263
264         power_range = p + i + d;
265
266         /* feed-forward the known sustainable dissipatable power */
267         power_range = sustainable_power + frac_to_int(power_range);
268
269         power_range = clamp(power_range, (s64)0, (s64)max_allocatable_power);
270
271         trace_thermal_power_allocator_pid(tz, frac_to_int(err),
272                                           frac_to_int(params->err_integral),
273                                           frac_to_int(p), frac_to_int(i),
274                                           frac_to_int(d), power_range);
275
276         return power_range;
277 }
278
279 /**
280  * power_actor_set_power() - limit the maximum power a cooling device consumes
281  * @cdev:       pointer to &thermal_cooling_device
282  * @instance:   thermal instance to update
283  * @power:      the power in milliwatts
284  *
285  * Set the cooling device to consume at most @power milliwatts. The limit is
286  * expected to be a cap at the maximum power consumption.
287  *
288  * Return: 0 on success, -EINVAL if the cooling device does not
289  * implement the power actor API or -E* for other failures.
290  */
291 static int
292 power_actor_set_power(struct thermal_cooling_device *cdev,
293                       struct thermal_instance *instance, u32 power)
294 {
295         unsigned long state;
296         int ret;
297
298         ret = cdev->ops->power2state(cdev, power, &state);
299         if (ret)
300                 return ret;
301
302         instance->target = clamp_val(state, instance->lower, instance->upper);
303         mutex_lock(&cdev->lock);
304         __thermal_cdev_update(cdev);
305         mutex_unlock(&cdev->lock);
306
307         return 0;
308 }
309
310 /**
311  * divvy_up_power() - divvy the allocated power between the actors
312  * @req_power:  each actor's requested power
313  * @max_power:  each actor's maximum available power
314  * @num_actors: size of the @req_power, @max_power and @granted_power's array
315  * @total_req_power: sum of @req_power
316  * @power_range:        total allocated power
317  * @granted_power:      output array: each actor's granted power
318  * @extra_actor_power:  an appropriately sized array to be used in the
319  *                      function as temporary storage of the extra power given
320  *                      to the actors
321  *
322  * This function divides the total allocated power (@power_range)
323  * fairly between the actors.  It first tries to give each actor a
324  * share of the @power_range according to how much power it requested
325  * compared to the rest of the actors.  For example, if only one actor
326  * requests power, then it receives all the @power_range.  If
327  * three actors each requests 1mW, each receives a third of the
328  * @power_range.
329  *
330  * If any actor received more than their maximum power, then that
331  * surplus is re-divvied among the actors based on how far they are
332  * from their respective maximums.
333  *
334  * Granted power for each actor is written to @granted_power, which
335  * should've been allocated by the calling function.
336  */
337 static void divvy_up_power(u32 *req_power, u32 *max_power, int num_actors,
338                            u32 total_req_power, u32 power_range,
339                            u32 *granted_power, u32 *extra_actor_power)
340 {
341         u32 extra_power, capped_extra_power;
342         int i;
343
344         /*
345          * Prevent division by 0 if none of the actors request power.
346          */
347         if (!total_req_power)
348                 total_req_power = 1;
349
350         capped_extra_power = 0;
351         extra_power = 0;
352         for (i = 0; i < num_actors; i++) {
353                 u64 req_range = (u64)req_power[i] * power_range;
354
355                 granted_power[i] = DIV_ROUND_CLOSEST_ULL(req_range,
356                                                          total_req_power);
357
358                 if (granted_power[i] > max_power[i]) {
359                         extra_power += granted_power[i] - max_power[i];
360                         granted_power[i] = max_power[i];
361                 }
362
363                 extra_actor_power[i] = max_power[i] - granted_power[i];
364                 capped_extra_power += extra_actor_power[i];
365         }
366
367         if (!extra_power)
368                 return;
369
370         /*
371          * Re-divvy the reclaimed extra among actors based on
372          * how far they are from the max
373          */
374         extra_power = min(extra_power, capped_extra_power);
375         if (capped_extra_power > 0)
376                 for (i = 0; i < num_actors; i++) {
377                         u64 extra_range = (u64)extra_actor_power[i] * extra_power;
378                         granted_power[i] += DIV_ROUND_CLOSEST_ULL(extra_range,
379                                                          capped_extra_power);
380                 }
381 }
382
383 static int allocate_power(struct thermal_zone_device *tz,
384                           int control_temp)
385 {
386         struct thermal_instance *instance;
387         struct power_allocator_params *params = tz->governor_data;
388         u32 *req_power, *max_power, *granted_power, *extra_actor_power;
389         u32 *weighted_req_power;
390         u32 total_req_power, max_allocatable_power, total_weighted_req_power;
391         u32 total_granted_power, power_range;
392         int i, num_actors, total_weight, ret = 0;
393         int trip_max_desired_temperature = params->trip_max_desired_temperature;
394
395         mutex_lock(&tz->lock);
396
397         num_actors = 0;
398         total_weight = 0;
399         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
400                 if ((instance->trip == trip_max_desired_temperature) &&
401                     cdev_is_power_actor(instance->cdev)) {
402                         num_actors++;
403                         total_weight += instance->weight;
404                 }
405         }
406
407         if (!num_actors) {
408                 ret = -ENODEV;
409                 goto unlock;
410         }
411
412         /*
413          * We need to allocate five arrays of the same size:
414          * req_power, max_power, granted_power, extra_actor_power and
415          * weighted_req_power.  They are going to be needed until this
416          * function returns.  Allocate them all in one go to simplify
417          * the allocation and deallocation logic.
418          */
419         BUILD_BUG_ON(sizeof(*req_power) != sizeof(*max_power));
420         BUILD_BUG_ON(sizeof(*req_power) != sizeof(*granted_power));
421         BUILD_BUG_ON(sizeof(*req_power) != sizeof(*extra_actor_power));
422         BUILD_BUG_ON(sizeof(*req_power) != sizeof(*weighted_req_power));
423         req_power = kcalloc(num_actors * 5, sizeof(*req_power), GFP_KERNEL);
424         if (!req_power) {
425                 ret = -ENOMEM;
426                 goto unlock;
427         }
428
429         max_power = &req_power[num_actors];
430         granted_power = &req_power[2 * num_actors];
431         extra_actor_power = &req_power[3 * num_actors];
432         weighted_req_power = &req_power[4 * num_actors];
433
434         i = 0;
435         total_weighted_req_power = 0;
436         total_req_power = 0;
437         max_allocatable_power = 0;
438
439         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
440                 int weight;
441                 struct thermal_cooling_device *cdev = instance->cdev;
442
443                 if (instance->trip != trip_max_desired_temperature)
444                         continue;
445
446                 if (!cdev_is_power_actor(cdev))
447                         continue;
448
449                 if (cdev->ops->get_requested_power(cdev, &req_power[i]))
450                         continue;
451
452                 if (!total_weight)
453                         weight = 1 << FRAC_BITS;
454                 else
455                         weight = instance->weight;
456
457                 weighted_req_power[i] = frac_to_int(weight * req_power[i]);
458
459                 if (cdev->ops->state2power(cdev, instance->lower,
460                                            &max_power[i]))
461                         continue;
462
463                 total_req_power += req_power[i];
464                 max_allocatable_power += max_power[i];
465                 total_weighted_req_power += weighted_req_power[i];
466
467                 i++;
468         }
469
470         power_range = pid_controller(tz, control_temp, max_allocatable_power);
471
472         divvy_up_power(weighted_req_power, max_power, num_actors,
473                        total_weighted_req_power, power_range, granted_power,
474                        extra_actor_power);
475
476         total_granted_power = 0;
477         i = 0;
478         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
479                 if (instance->trip != trip_max_desired_temperature)
480                         continue;
481
482                 if (!cdev_is_power_actor(instance->cdev))
483                         continue;
484
485                 power_actor_set_power(instance->cdev, instance,
486                                       granted_power[i]);
487                 total_granted_power += granted_power[i];
488
489                 i++;
490         }
491
492         trace_thermal_power_allocator(tz, req_power, total_req_power,
493                                       granted_power, total_granted_power,
494                                       num_actors, power_range,
495                                       max_allocatable_power, tz->temperature,
496                                       control_temp - tz->temperature);
497
498         kfree(req_power);
499 unlock:
500         mutex_unlock(&tz->lock);
501
502         return ret;
503 }
504
505 /**
506  * get_governor_trips() - get the number of the two trip points that are key for this governor
507  * @tz: thermal zone to operate on
508  * @params:     pointer to private data for this governor
509  *
510  * The power allocator governor works optimally with two trips points:
511  * a "switch on" trip point and a "maximum desired temperature".  These
512  * are defined as the first and last passive trip points.
513  *
514  * If there is only one trip point, then that's considered to be the
515  * "maximum desired temperature" trip point and the governor is always
516  * on.  If there are no passive or active trip points, then the
517  * governor won't do anything.  In fact, its throttle function
518  * won't be called at all.
519  */
520 static void get_governor_trips(struct thermal_zone_device *tz,
521                                struct power_allocator_params *params)
522 {
523         int i, last_active, last_passive;
524         bool found_first_passive;
525
526         found_first_passive = false;
527         last_active = INVALID_TRIP;
528         last_passive = INVALID_TRIP;
529
530         for (i = 0; i < tz->trips; i++) {
531                 enum thermal_trip_type type;
532                 int ret;
533
534                 ret = tz->ops->get_trip_type(tz, i, &type);
535                 if (ret) {
536                         dev_warn(&tz->device,
537                                  "Failed to get trip point %d type: %d\n", i,
538                                  ret);
539                         continue;
540                 }
541
542                 if (type == THERMAL_TRIP_PASSIVE) {
543                         if (!found_first_passive) {
544                                 params->trip_switch_on = i;
545                                 found_first_passive = true;
546                         } else  {
547                                 last_passive = i;
548                         }
549                 } else if (type == THERMAL_TRIP_ACTIVE) {
550                         last_active = i;
551                 } else {
552                         break;
553                 }
554         }
555
556         if (last_passive != INVALID_TRIP) {
557                 params->trip_max_desired_temperature = last_passive;
558         } else if (found_first_passive) {
559                 params->trip_max_desired_temperature = params->trip_switch_on;
560                 params->trip_switch_on = INVALID_TRIP;
561         } else {
562                 params->trip_switch_on = INVALID_TRIP;
563                 params->trip_max_desired_temperature = last_active;
564         }
565 }
566
567 static void reset_pid_controller(struct power_allocator_params *params)
568 {
569         params->err_integral = 0;
570         params->prev_err = 0;
571 }
572
573 static void allow_maximum_power(struct thermal_zone_device *tz, bool update)
574 {
575         struct thermal_instance *instance;
576         struct power_allocator_params *params = tz->governor_data;
577         u32 req_power;
578
579         mutex_lock(&tz->lock);
580         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
581                 struct thermal_cooling_device *cdev = instance->cdev;
582
583                 if ((instance->trip != params->trip_max_desired_temperature) ||
584                     (!cdev_is_power_actor(instance->cdev)))
585                         continue;
586
587                 instance->target = 0;
588                 mutex_lock(&instance->cdev->lock);
589                 /*
590                  * Call for updating the cooling devices local stats and avoid
591                  * periods of dozen of seconds when those have not been
592                  * maintained.
593                  */
594                 cdev->ops->get_requested_power(cdev, &req_power);
595
596                 if (update)
597                         __thermal_cdev_update(instance->cdev);
598
599                 mutex_unlock(&instance->cdev->lock);
600         }
601         mutex_unlock(&tz->lock);
602 }
603
604 /**
605  * check_power_actors() - Check all cooling devices and warn when they are
606  *                      not power actors
607  * @tz:         thermal zone to operate on
608  *
609  * Check all cooling devices in the @tz and warn every time they are missing
610  * power actor API. The warning should help to investigate the issue, which
611  * could be e.g. lack of Energy Model for a given device.
612  *
613  * Return: 0 on success, -EINVAL if any cooling device does not implement
614  * the power actor API.
615  */
616 static int check_power_actors(struct thermal_zone_device *tz)
617 {
618         struct thermal_instance *instance;
619         int ret = 0;
620
621         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
622                 if (!cdev_is_power_actor(instance->cdev)) {
623                         dev_warn(&tz->device, "power_allocator: %s is not a power actor\n",
624                                  instance->cdev->type);
625                         ret = -EINVAL;
626                 }
627         }
628
629         return ret;
630 }
631
632 /**
633  * power_allocator_bind() - bind the power_allocator governor to a thermal zone
634  * @tz: thermal zone to bind it to
635  *
636  * Initialize the PID controller parameters and bind it to the thermal
637  * zone.
638  *
639  * Return: 0 on success, or -ENOMEM if we ran out of memory, or -EINVAL
640  * when there are unsupported cooling devices in the @tz.
641  */
642 static int power_allocator_bind(struct thermal_zone_device *tz)
643 {
644         int ret;
645         struct power_allocator_params *params;
646         int control_temp;
647
648         ret = check_power_actors(tz);
649         if (ret)
650                 return ret;
651
652         params = kzalloc(sizeof(*params), GFP_KERNEL);
653         if (!params)
654                 return -ENOMEM;
655
656         if (!tz->tzp) {
657                 tz->tzp = kzalloc(sizeof(*tz->tzp), GFP_KERNEL);
658                 if (!tz->tzp) {
659                         ret = -ENOMEM;
660                         goto free_params;
661                 }
662
663                 params->allocated_tzp = true;
664         }
665
666         if (!tz->tzp->sustainable_power)
667                 dev_warn(&tz->device, "power_allocator: sustainable_power will be estimated\n");
668
669         get_governor_trips(tz, params);
670
671         if (tz->trips > 0) {
672                 ret = tz->ops->get_trip_temp(tz,
673                                         params->trip_max_desired_temperature,
674                                         &control_temp);
675                 if (!ret)
676                         estimate_pid_constants(tz, tz->tzp->sustainable_power,
677                                                params->trip_switch_on,
678                                                control_temp);
679         }
680
681         reset_pid_controller(params);
682
683         tz->governor_data = params;
684
685         return 0;
686
687 free_params:
688         kfree(params);
689
690         return ret;
691 }
692
693 static void power_allocator_unbind(struct thermal_zone_device *tz)
694 {
695         struct power_allocator_params *params = tz->governor_data;
696
697         dev_dbg(&tz->device, "Unbinding from thermal zone %d\n", tz->id);
698
699         if (params->allocated_tzp) {
700                 kfree(tz->tzp);
701                 tz->tzp = NULL;
702         }
703
704         kfree(tz->governor_data);
705         tz->governor_data = NULL;
706 }
707
708 static int power_allocator_throttle(struct thermal_zone_device *tz, int trip)
709 {
710         int ret;
711         int switch_on_temp, control_temp;
712         struct power_allocator_params *params = tz->governor_data;
713         bool update;
714
715         /*
716          * We get called for every trip point but we only need to do
717          * our calculations once
718          */
719         if (trip != params->trip_max_desired_temperature)
720                 return 0;
721
722         ret = tz->ops->get_trip_temp(tz, params->trip_switch_on,
723                                      &switch_on_temp);
724         if (!ret && (tz->temperature < switch_on_temp)) {
725                 update = (tz->last_temperature >= switch_on_temp);
726                 tz->passive = 0;
727                 reset_pid_controller(params);
728                 allow_maximum_power(tz, update);
729                 return 0;
730         }
731
732         tz->passive = 1;
733
734         ret = tz->ops->get_trip_temp(tz, params->trip_max_desired_temperature,
735                                 &control_temp);
736         if (ret) {
737                 dev_warn(&tz->device,
738                          "Failed to get the maximum desired temperature: %d\n",
739                          ret);
740                 return ret;
741         }
742
743         return allocate_power(tz, control_temp);
744 }
745
746 static struct thermal_governor thermal_gov_power_allocator = {
747         .name           = "power_allocator",
748         .bind_to_tz     = power_allocator_bind,
749         .unbind_from_tz = power_allocator_unbind,
750         .throttle       = power_allocator_throttle,