thermal/core/power_allocator: Update once cooling devices when temp is low
[platform/kernel/linux-starfive.git] / drivers / thermal / gov_power_allocator.c
1 // SPDX-License-Identifier: GPL-2.0
2 /*
3  * A power allocator to manage temperature
4  *
5  * Copyright (C) 2014 ARM Ltd.
6  *
7  */
8
9 #define pr_fmt(fmt) "Power allocator: " fmt
10
11 #include <linux/rculist.h>
12 #include <linux/slab.h>
13 #include <linux/thermal.h>
14
15 #define CREATE_TRACE_POINTS
16 #include <trace/events/thermal_power_allocator.h>
17
18 #include "thermal_core.h"
19
20 #define INVALID_TRIP -1
21
22 #define FRAC_BITS 10
23 #define int_to_frac(x) ((x) << FRAC_BITS)
24 #define frac_to_int(x) ((x) >> FRAC_BITS)
25
26 /**
27  * mul_frac() - multiply two fixed-point numbers
28  * @x:  first multiplicand
29  * @y:  second multiplicand
30  *
31  * Return: the result of multiplying two fixed-point numbers.  The
32  * result is also a fixed-point number.
33  */
34 static inline s64 mul_frac(s64 x, s64 y)
35 {
36         return (x * y) >> FRAC_BITS;
37 }
38
39 /**
40  * div_frac() - divide two fixed-point numbers
41  * @x:  the dividend
42  * @y:  the divisor
43  *
44  * Return: the result of dividing two fixed-point numbers.  The
45  * result is also a fixed-point number.
46  */
47 static inline s64 div_frac(s64 x, s64 y)
48 {
49         return div_s64(x << FRAC_BITS, y);
50 }
51
52 /**
53  * struct power_allocator_params - parameters for the power allocator governor
54  * @allocated_tzp:      whether we have allocated tzp for this thermal zone and
55  *                      it needs to be freed on unbind
56  * @err_integral:       accumulated error in the PID controller.
57  * @prev_err:   error in the previous iteration of the PID controller.
58  *              Used to calculate the derivative term.
59  * @trip_switch_on:     first passive trip point of the thermal zone.  The
60  *                      governor switches on when this trip point is crossed.
61  *                      If the thermal zone only has one passive trip point,
62  *                      @trip_switch_on should be INVALID_TRIP.
63  * @trip_max_desired_temperature:       last passive trip point of the thermal
64  *                                      zone.  The temperature we are
65  *                                      controlling for.
66  * @sustainable_power:  Sustainable power (heat) that this thermal zone can
67  *                      dissipate
68  */
69 struct power_allocator_params {
70         bool allocated_tzp;
71         s64 err_integral;
72         s32 prev_err;
73         int trip_switch_on;
74         int trip_max_desired_temperature;
75         u32 sustainable_power;
76 };
77
78 /**
79  * estimate_sustainable_power() - Estimate the sustainable power of a thermal zone
80  * @tz: thermal zone we are operating in
81  *
82  * For thermal zones that don't provide a sustainable_power in their
83  * thermal_zone_params, estimate one.  Calculate it using the minimum
84  * power of all the cooling devices as that gives a valid value that
85  * can give some degree of functionality.  For optimal performance of
86  * this governor, provide a sustainable_power in the thermal zone's
87  * thermal_zone_params.
88  */
89 static u32 estimate_sustainable_power(struct thermal_zone_device *tz)
90 {
91         u32 sustainable_power = 0;
92         struct thermal_instance *instance;
93         struct power_allocator_params *params = tz->governor_data;
94
95         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
96                 struct thermal_cooling_device *cdev = instance->cdev;
97                 u32 min_power;
98
99                 if (instance->trip != params->trip_max_desired_temperature)
100                         continue;
101
102                 if (!cdev_is_power_actor(cdev))
103                         continue;
104
105                 if (cdev->ops->state2power(cdev, instance->upper, &min_power))
106                         continue;
107
108                 sustainable_power += min_power;
109         }
110
111         return sustainable_power;
112 }
113
114 /**
115  * estimate_pid_constants() - Estimate the constants for the PID controller
116  * @tz:         thermal zone for which to estimate the constants
117  * @sustainable_power:  sustainable power for the thermal zone
118  * @trip_switch_on:     trip point number for the switch on temperature
119  * @control_temp:       target temperature for the power allocator governor
120  *
121  * This function is used to update the estimation of the PID
122  * controller constants in struct thermal_zone_parameters.
123  */
124 static void estimate_pid_constants(struct thermal_zone_device *tz,
125                                    u32 sustainable_power, int trip_switch_on,
126                                    int control_temp)
127 {
128         int ret;
129         int switch_on_temp;
130         u32 temperature_threshold;
131         s32 k_i;
132
133         ret = tz->ops->get_trip_temp(tz, trip_switch_on, &switch_on_temp);
134         if (ret)
135                 switch_on_temp = 0;
136
137         temperature_threshold = control_temp - switch_on_temp;
138         /*
139          * estimate_pid_constants() tries to find appropriate default
140          * values for thermal zones that don't provide them. If a
141          * system integrator has configured a thermal zone with two
142          * passive trip points at the same temperature, that person
143          * hasn't put any effort to set up the thermal zone properly
144          * so just give up.
145          */
146         if (!temperature_threshold)
147                 return;
148
149         tz->tzp->k_po = int_to_frac(sustainable_power) /
150                 temperature_threshold;
151
152         tz->tzp->k_pu = int_to_frac(2 * sustainable_power) /
153                 temperature_threshold;
154
155         k_i = tz->tzp->k_pu / 10;
156         tz->tzp->k_i = k_i > 0 ? k_i : 1;
157
158         /*
159          * The default for k_d and integral_cutoff is 0, so we can
160          * leave them as they are.
161          */
162 }
163
164 /**
165  * get_sustainable_power() - Get the right sustainable power
166  * @tz:         thermal zone for which to estimate the constants
167  * @params:     parameters for the power allocator governor
168  * @control_temp:       target temperature for the power allocator governor
169  *
170  * This function is used for getting the proper sustainable power value based
171  * on variables which might be updated by the user sysfs interface. If that
172  * happen the new value is going to be estimated and updated. It is also used
173  * after thermal zone binding, where the initial values where set to 0.
174  */
175 static u32 get_sustainable_power(struct thermal_zone_device *tz,
176                                  struct power_allocator_params *params,
177                                  int control_temp)
178 {
179         u32 sustainable_power;
180
181         if (!tz->tzp->sustainable_power)
182                 sustainable_power = estimate_sustainable_power(tz);
183         else
184                 sustainable_power = tz->tzp->sustainable_power;
185
186         /* Check if it's init value 0 or there was update via sysfs */
187         if (sustainable_power != params->sustainable_power) {
188                 estimate_pid_constants(tz, sustainable_power,
189                                        params->trip_switch_on, control_temp);
190
191                 /* Do the estimation only once and make available in sysfs */
192                 tz->tzp->sustainable_power = sustainable_power;
193                 params->sustainable_power = sustainable_power;
194         }
195
196         return sustainable_power;
197 }
198
199 /**
200  * pid_controller() - PID controller
201  * @tz: thermal zone we are operating in
202  * @control_temp:       the target temperature in millicelsius
203  * @max_allocatable_power:      maximum allocatable power for this thermal zone
204  *
205  * This PID controller increases the available power budget so that the
206  * temperature of the thermal zone gets as close as possible to
207  * @control_temp and limits the power if it exceeds it.  k_po is the
208  * proportional term when we are overshooting, k_pu is the
209  * proportional term when we are undershooting.  integral_cutoff is a
210  * threshold below which we stop accumulating the error.  The
211  * accumulated error is only valid if the requested power will make
212  * the system warmer.  If the system is mostly idle, there's no point
213  * in accumulating positive error.
214  *
215  * Return: The power budget for the next period.
216  */
217 static u32 pid_controller(struct thermal_zone_device *tz,
218                           int control_temp,
219                           u32 max_allocatable_power)
220 {
221         s64 p, i, d, power_range;
222         s32 err, max_power_frac;
223         u32 sustainable_power;
224         struct power_allocator_params *params = tz->governor_data;
225
226         max_power_frac = int_to_frac(max_allocatable_power);
227
228         sustainable_power = get_sustainable_power(tz, params, control_temp);
229
230         err = control_temp - tz->temperature;
231         err = int_to_frac(err);
232
233         /* Calculate the proportional term */
234         p = mul_frac(err < 0 ? tz->tzp->k_po : tz->tzp->k_pu, err);
235
236         /*
237          * Calculate the integral term
238          *
239          * if the error is less than cut off allow integration (but
240          * the integral is limited to max power)
241          */
242         i = mul_frac(tz->tzp->k_i, params->err_integral);
243
244         if (err < int_to_frac(tz->tzp->integral_cutoff)) {
245                 s64 i_next = i + mul_frac(tz->tzp->k_i, err);
246
247                 if (abs(i_next) < max_power_frac) {
248                         i = i_next;
249                         params->err_integral += err;
250                 }
251         }
252
253         /*
254          * Calculate the derivative term
255          *
256          * We do err - prev_err, so with a positive k_d, a decreasing
257          * error (i.e. driving closer to the line) results in less
258          * power being applied, slowing down the controller)
259          */
260         d = mul_frac(tz->tzp->k_d, err - params->prev_err);
261         d = div_frac(d, jiffies_to_msecs(tz->passive_delay_jiffies));
262         params->prev_err = err;
263
264         power_range = p + i + d;
265
266         /* feed-forward the known sustainable dissipatable power */
267         power_range = sustainable_power + frac_to_int(power_range);
268
269         power_range = clamp(power_range, (s64)0, (s64)max_allocatable_power);
270
271         trace_thermal_power_allocator_pid(tz, frac_to_int(err),
272                                           frac_to_int(params->err_integral),
273                                           frac_to_int(p), frac_to_int(i),
274                                           frac_to_int(d), power_range);
275
276         return power_range;
277 }
278
279 /**
280  * power_actor_set_power() - limit the maximum power a cooling device consumes
281  * @cdev:       pointer to &thermal_cooling_device
282  * @instance:   thermal instance to update
283  * @power:      the power in milliwatts
284  *
285  * Set the cooling device to consume at most @power milliwatts. The limit is
286  * expected to be a cap at the maximum power consumption.
287  *
288  * Return: 0 on success, -EINVAL if the cooling device does not
289  * implement the power actor API or -E* for other failures.
290  */
291 static int
292 power_actor_set_power(struct thermal_cooling_device *cdev,
293                       struct thermal_instance *instance, u32 power)
294 {
295         unsigned long state;
296         int ret;
297
298         ret = cdev->ops->power2state(cdev, power, &state);
299         if (ret)
300                 return ret;
301
302         instance->target = clamp_val(state, instance->lower, instance->upper);
303         mutex_lock(&cdev->lock);
304         cdev->updated = false;
305         mutex_unlock(&cdev->lock);
306         thermal_cdev_update(cdev);
307
308         return 0;
309 }
310
311 /**
312  * divvy_up_power() - divvy the allocated power between the actors
313  * @req_power:  each actor's requested power
314  * @max_power:  each actor's maximum available power
315  * @num_actors: size of the @req_power, @max_power and @granted_power's array
316  * @total_req_power: sum of @req_power
317  * @power_range:        total allocated power
318  * @granted_power:      output array: each actor's granted power
319  * @extra_actor_power:  an appropriately sized array to be used in the
320  *                      function as temporary storage of the extra power given
321  *                      to the actors
322  *
323  * This function divides the total allocated power (@power_range)
324  * fairly between the actors.  It first tries to give each actor a
325  * share of the @power_range according to how much power it requested
326  * compared to the rest of the actors.  For example, if only one actor
327  * requests power, then it receives all the @power_range.  If
328  * three actors each requests 1mW, each receives a third of the
329  * @power_range.
330  *
331  * If any actor received more than their maximum power, then that
332  * surplus is re-divvied among the actors based on how far they are
333  * from their respective maximums.
334  *
335  * Granted power for each actor is written to @granted_power, which
336  * should've been allocated by the calling function.
337  */
338 static void divvy_up_power(u32 *req_power, u32 *max_power, int num_actors,
339                            u32 total_req_power, u32 power_range,
340                            u32 *granted_power, u32 *extra_actor_power)
341 {
342         u32 extra_power, capped_extra_power;
343         int i;
344
345         /*
346          * Prevent division by 0 if none of the actors request power.
347          */
348         if (!total_req_power)
349                 total_req_power = 1;
350
351         capped_extra_power = 0;
352         extra_power = 0;
353         for (i = 0; i < num_actors; i++) {
354                 u64 req_range = (u64)req_power[i] * power_range;
355
356                 granted_power[i] = DIV_ROUND_CLOSEST_ULL(req_range,
357                                                          total_req_power);
358
359                 if (granted_power[i] > max_power[i]) {
360                         extra_power += granted_power[i] - max_power[i];
361                         granted_power[i] = max_power[i];
362                 }
363
364                 extra_actor_power[i] = max_power[i] - granted_power[i];
365                 capped_extra_power += extra_actor_power[i];
366         }
367
368         if (!extra_power)
369                 return;
370
371         /*
372          * Re-divvy the reclaimed extra among actors based on
373          * how far they are from the max
374          */
375         extra_power = min(extra_power, capped_extra_power);
376         if (capped_extra_power > 0)
377                 for (i = 0; i < num_actors; i++) {
378                         u64 extra_range = (u64)extra_actor_power[i] * extra_power;
379                         granted_power[i] += DIV_ROUND_CLOSEST_ULL(extra_range,
380                                                          capped_extra_power);
381                 }
382 }
383
384 static int allocate_power(struct thermal_zone_device *tz,
385                           int control_temp)
386 {
387         struct thermal_instance *instance;
388         struct power_allocator_params *params = tz->governor_data;
389         u32 *req_power, *max_power, *granted_power, *extra_actor_power;
390         u32 *weighted_req_power;
391         u32 total_req_power, max_allocatable_power, total_weighted_req_power;
392         u32 total_granted_power, power_range;
393         int i, num_actors, total_weight, ret = 0;
394         int trip_max_desired_temperature = params->trip_max_desired_temperature;
395
396         mutex_lock(&tz->lock);
397
398         num_actors = 0;
399         total_weight = 0;
400         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
401                 if ((instance->trip == trip_max_desired_temperature) &&
402                     cdev_is_power_actor(instance->cdev)) {
403                         num_actors++;
404                         total_weight += instance->weight;
405                 }
406         }
407
408         if (!num_actors) {
409                 ret = -ENODEV;
410                 goto unlock;
411         }
412
413         /*
414          * We need to allocate five arrays of the same size:
415          * req_power, max_power, granted_power, extra_actor_power and
416          * weighted_req_power.  They are going to be needed until this
417          * function returns.  Allocate them all in one go to simplify
418          * the allocation and deallocation logic.
419          */
420         BUILD_BUG_ON(sizeof(*req_power) != sizeof(*max_power));
421         BUILD_BUG_ON(sizeof(*req_power) != sizeof(*granted_power));
422         BUILD_BUG_ON(sizeof(*req_power) != sizeof(*extra_actor_power));
423         BUILD_BUG_ON(sizeof(*req_power) != sizeof(*weighted_req_power));
424         req_power = kcalloc(num_actors * 5, sizeof(*req_power), GFP_KERNEL);
425         if (!req_power) {
426                 ret = -ENOMEM;
427                 goto unlock;
428         }
429
430         max_power = &req_power[num_actors];
431         granted_power = &req_power[2 * num_actors];
432         extra_actor_power = &req_power[3 * num_actors];
433         weighted_req_power = &req_power[4 * num_actors];
434
435         i = 0;
436         total_weighted_req_power = 0;
437         total_req_power = 0;
438         max_allocatable_power = 0;
439
440         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
441                 int weight;
442                 struct thermal_cooling_device *cdev = instance->cdev;
443
444                 if (instance->trip != trip_max_desired_temperature)
445                         continue;
446
447                 if (!cdev_is_power_actor(cdev))
448                         continue;
449
450                 if (cdev->ops->get_requested_power(cdev, &req_power[i]))
451                         continue;
452
453                 if (!total_weight)
454                         weight = 1 << FRAC_BITS;
455                 else
456                         weight = instance->weight;
457
458                 weighted_req_power[i] = frac_to_int(weight * req_power[i]);
459
460                 if (cdev->ops->state2power(cdev, instance->lower,
461                                            &max_power[i]))
462                         continue;
463
464                 total_req_power += req_power[i];
465                 max_allocatable_power += max_power[i];
466                 total_weighted_req_power += weighted_req_power[i];
467
468                 i++;
469         }
470
471         power_range = pid_controller(tz, control_temp, max_allocatable_power);
472
473         divvy_up_power(weighted_req_power, max_power, num_actors,
474                        total_weighted_req_power, power_range, granted_power,
475                        extra_actor_power);
476
477         total_granted_power = 0;
478         i = 0;
479         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
480                 if (instance->trip != trip_max_desired_temperature)
481                         continue;
482
483                 if (!cdev_is_power_actor(instance->cdev))
484                         continue;
485
486                 power_actor_set_power(instance->cdev, instance,
487                                       granted_power[i]);
488                 total_granted_power += granted_power[i];
489
490                 i++;
491         }
492
493         trace_thermal_power_allocator(tz, req_power, total_req_power,
494                                       granted_power, total_granted_power,
495                                       num_actors, power_range,
496                                       max_allocatable_power, tz->temperature,
497                                       control_temp - tz->temperature);
498
499         kfree(req_power);
500 unlock:
501         mutex_unlock(&tz->lock);
502
503         return ret;
504 }
505
506 /**
507  * get_governor_trips() - get the number of the two trip points that are key for this governor
508  * @tz: thermal zone to operate on
509  * @params:     pointer to private data for this governor
510  *
511  * The power allocator governor works optimally with two trips points:
512  * a "switch on" trip point and a "maximum desired temperature".  These
513  * are defined as the first and last passive trip points.
514  *
515  * If there is only one trip point, then that's considered to be the
516  * "maximum desired temperature" trip point and the governor is always
517  * on.  If there are no passive or active trip points, then the
518  * governor won't do anything.  In fact, its throttle function
519  * won't be called at all.
520  */
521 static void get_governor_trips(struct thermal_zone_device *tz,
522                                struct power_allocator_params *params)
523 {
524         int i, last_active, last_passive;
525         bool found_first_passive;
526
527         found_first_passive = false;
528         last_active = INVALID_TRIP;
529         last_passive = INVALID_TRIP;
530
531         for (i = 0; i < tz->trips; i++) {
532                 enum thermal_trip_type type;
533                 int ret;
534
535                 ret = tz->ops->get_trip_type(tz, i, &type);
536                 if (ret) {
537                         dev_warn(&tz->device,
538                                  "Failed to get trip point %d type: %d\n", i,
539                                  ret);
540                         continue;
541                 }
542
543                 if (type == THERMAL_TRIP_PASSIVE) {
544                         if (!found_first_passive) {
545                                 params->trip_switch_on = i;
546                                 found_first_passive = true;
547                         } else  {
548                                 last_passive = i;
549                         }
550                 } else if (type == THERMAL_TRIP_ACTIVE) {
551                         last_active = i;
552                 } else {
553                         break;
554                 }
555         }
556
557         if (last_passive != INVALID_TRIP) {
558                 params->trip_max_desired_temperature = last_passive;
559         } else if (found_first_passive) {
560                 params->trip_max_desired_temperature = params->trip_switch_on;
561                 params->trip_switch_on = INVALID_TRIP;
562         } else {
563                 params->trip_switch_on = INVALID_TRIP;
564                 params->trip_max_desired_temperature = last_active;
565         }
566 }
567
568 static void reset_pid_controller(struct power_allocator_params *params)
569 {
570         params->err_integral = 0;
571         params->prev_err = 0;
572 }
573
574 static void allow_maximum_power(struct thermal_zone_device *tz, bool update)
575 {
576         struct thermal_instance *instance;
577         struct power_allocator_params *params = tz->governor_data;
578         u32 req_power;
579
580         mutex_lock(&tz->lock);
581         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
582                 struct thermal_cooling_device *cdev = instance->cdev;
583
584                 if ((instance->trip != params->trip_max_desired_temperature) ||
585                     (!cdev_is_power_actor(instance->cdev)))
586                         continue;
587
588                 instance->target = 0;
589                 mutex_lock(&instance->cdev->lock);
590                 /*
591                  * Call for updating the cooling devices local stats and avoid
592                  * periods of dozen of seconds when those have not been
593                  * maintained.
594                  */
595                 cdev->ops->get_requested_power(cdev, &req_power);
596
597                 if (update)
598                         __thermal_cdev_update(instance->cdev);
599
600                 mutex_unlock(&instance->cdev->lock);
601         }
602         mutex_unlock(&tz->lock);
603 }
604
605 /**
606  * check_power_actors() - Check all cooling devices and warn when they are
607  *                      not power actors
608  * @tz:         thermal zone to operate on
609  *
610  * Check all cooling devices in the @tz and warn every time they are missing
611  * power actor API. The warning should help to investigate the issue, which
612  * could be e.g. lack of Energy Model for a given device.
613  *
614  * Return: 0 on success, -EINVAL if any cooling device does not implement
615  * the power actor API.
616  */
617 static int check_power_actors(struct thermal_zone_device *tz)
618 {
619         struct thermal_instance *instance;
620         int ret = 0;
621
622         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
623                 if (!cdev_is_power_actor(instance->cdev)) {
624                         dev_warn(&tz->device, "power_allocator: %s is not a power actor\n",
625                                  instance->cdev->type);
626                         ret = -EINVAL;
627                 }
628         }
629
630         return ret;
631 }
632
633 /**
634  * power_allocator_bind() - bind the power_allocator governor to a thermal zone
635  * @tz: thermal zone to bind it to
636  *
637  * Initialize the PID controller parameters and bind it to the thermal
638  * zone.
639  *
640  * Return: 0 on success, or -ENOMEM if we ran out of memory, or -EINVAL
641  * when there are unsupported cooling devices in the @tz.
642  */
643 static int power_allocator_bind(struct thermal_zone_device *tz)
644 {
645         int ret;
646         struct power_allocator_params *params;
647         int control_temp;
648
649         ret = check_power_actors(tz);
650         if (ret)
651                 return ret;
652
653         params = kzalloc(sizeof(*params), GFP_KERNEL);
654         if (!params)
655                 return -ENOMEM;
656
657         if (!tz->tzp) {
658                 tz->tzp = kzalloc(sizeof(*tz->tzp), GFP_KERNEL);
659                 if (!tz->tzp) {
660                         ret = -ENOMEM;
661                         goto free_params;
662                 }
663
664                 params->allocated_tzp = true;
665         }
666
667         if (!tz->tzp->sustainable_power)
668                 dev_warn(&tz->device, "power_allocator: sustainable_power will be estimated\n");
669
670         get_governor_trips(tz, params);
671
672         if (tz->trips > 0) {
673                 ret = tz->ops->get_trip_temp(tz,
674                                         params->trip_max_desired_temperature,
675                                         &control_temp);
676                 if (!ret)
677                         estimate_pid_constants(tz, tz->tzp->sustainable_power,
678                                                params->trip_switch_on,
679                                                control_temp);
680         }
681
682         reset_pid_controller(params);
683
684         tz->governor_data = params;
685
686         return 0;
687
688 free_params:
689         kfree(params);
690
691         return ret;
692 }
693
694 static void power_allocator_unbind(struct thermal_zone_device *tz)
695 {
696         struct power_allocator_params *params = tz->governor_data;
697
698         dev_dbg(&tz->device, "Unbinding from thermal zone %d\n", tz->id);
699
700         if (params->allocated_tzp) {
701                 kfree(tz->tzp);
702                 tz->tzp = NULL;
703         }
704
705         kfree(tz->governor_data);
706         tz->governor_data = NULL;
707 }
708
709 static int power_allocator_throttle(struct thermal_zone_device *tz, int trip)
710 {
711         int ret;
712         int switch_on_temp, control_temp;
713         struct power_allocator_params *params = tz->governor_data;
714         bool update;
715
716         /*
717          * We get called for every trip point but we only need to do
718          * our calculations once
719          */
720         if (trip != params->trip_max_desired_temperature)
721                 return 0;
722
723         ret = tz->ops->get_trip_temp(tz, params->trip_switch_on,
724                                      &switch_on_temp);
725         if (!ret && (tz->temperature < switch_on_temp)) {
726                 update = (tz->last_temperature >= switch_on_temp);
727                 tz->passive = 0;
728                 reset_pid_controller(params);
729                 allow_maximum_power(tz, update);
730                 return 0;
731         }
732
733         tz->passive = 1;
734
735         ret = tz->ops->get_trip_temp(tz, params->trip_max_desired_temperature,
736                                 &control_temp);
737         if (ret) {
738                 dev_warn(&tz->device,
739                          "Failed to get the maximum desired temperature: %d\n",
740                          ret);
741                 return ret;
742         }
743
744         return allocate_power(tz, control_temp);
745 }
746
747 static struct thermal_governor thermal_gov_power_allocator = {
748         .name           = "power_allocator",
749         .bind_to_tz     = power_allocator_bind,
750         .unbind_from_tz = power_allocator_unbind,
751         .throttle       = power_allocator_throttle,
752 };
753 THERMAL_GOVERNOR_DECLARE(thermal_gov_power_allocator);