Merge tag 'for-6.6-rc1-tag' of git://git.kernel.org/pub/scm/linux/kernel/git/kdave...
[platform/kernel/linux-rpi.git] / drivers / thermal / db8500_thermal.c
1 // SPDX-License-Identifier: GPL-2.0-or-later
2 /*
3  * db8500_thermal.c - DB8500 Thermal Management Implementation
4  *
5  * Copyright (C) 2012 ST-Ericsson
6  * Copyright (C) 2012-2019 Linaro Ltd.
7  *
8  * Authors: Hongbo Zhang, Linus Walleij
9  */
10
11 #include <linux/cpu_cooling.h>
12 #include <linux/interrupt.h>
13 #include <linux/mfd/dbx500-prcmu.h>
14 #include <linux/module.h>
15 #include <linux/of.h>
16 #include <linux/platform_device.h>
17 #include <linux/slab.h>
18 #include <linux/thermal.h>
19
20 #define PRCMU_DEFAULT_MEASURE_TIME      0xFFF
21 #define PRCMU_DEFAULT_LOW_TEMP          0
22
23 /**
24  * db8500_thermal_points - the interpolation points that trigger
25  * interrupts
26  */
27 static const unsigned long db8500_thermal_points[] = {
28         15000,
29         20000,
30         25000,
31         30000,
32         35000,
33         40000,
34         45000,
35         50000,
36         55000,
37         60000,
38         65000,
39         70000,
40         75000,
41         80000,
42         /*
43          * This is where things start to get really bad for the
44          * SoC and the thermal zones should be set up to trigger
45          * critical temperature at 85000 mC so we don't get above
46          * this point.
47          */
48         85000,
49         90000,
50         95000,
51         100000,
52 };
53
54 struct db8500_thermal_zone {
55         struct thermal_zone_device *tz;
56         struct device *dev;
57         unsigned long interpolated_temp;
58         unsigned int cur_index;
59 };
60
61 /* Callback to get current temperature */
62 static int db8500_thermal_get_temp(struct thermal_zone_device *tz, int *temp)
63 {
64         struct db8500_thermal_zone *th = thermal_zone_device_priv(tz);
65
66         /*
67          * TODO: There is no PRCMU interface to get temperature data currently,
68          * so a pseudo temperature is returned , it works for thermal framework
69          * and this will be fixed when the PRCMU interface is available.
70          */
71         *temp = th->interpolated_temp;
72
73         return 0;
74 }
75
76 static const struct thermal_zone_device_ops thdev_ops = {
77         .get_temp = db8500_thermal_get_temp,
78 };
79
80 static void db8500_thermal_update_config(struct db8500_thermal_zone *th,
81                                          unsigned int idx,
82                                          unsigned long next_low,
83                                          unsigned long next_high)
84 {
85         prcmu_stop_temp_sense();
86
87         th->cur_index = idx;
88         th->interpolated_temp = (next_low + next_high)/2;
89
90         /*
91          * The PRCMU accept absolute temperatures in celsius so divide
92          * down the millicelsius with 1000
93          */
94         prcmu_config_hotmon((u8)(next_low/1000), (u8)(next_high/1000));
95         prcmu_start_temp_sense(PRCMU_DEFAULT_MEASURE_TIME);
96 }
97
98 static irqreturn_t prcmu_low_irq_handler(int irq, void *irq_data)
99 {
100         struct db8500_thermal_zone *th = irq_data;
101         unsigned int idx = th->cur_index;
102         unsigned long next_low, next_high;
103
104         if (idx == 0)
105                 /* Meaningless for thermal management, ignoring it */
106                 return IRQ_HANDLED;
107
108         if (idx == 1) {
109                 next_high = db8500_thermal_points[0];
110                 next_low = PRCMU_DEFAULT_LOW_TEMP;
111         } else {
112                 next_high = db8500_thermal_points[idx - 1];
113                 next_low = db8500_thermal_points[idx - 2];
114         }
115         idx -= 1;
116
117         db8500_thermal_update_config(th, idx, next_low, next_high);
118         dev_dbg(th->dev,
119                 "PRCMU set max %ld, min %ld\n", next_high, next_low);
120
121         thermal_zone_device_update(th->tz, THERMAL_EVENT_UNSPECIFIED);
122
123         return IRQ_HANDLED;
124 }
125
126 static irqreturn_t prcmu_high_irq_handler(int irq, void *irq_data)
127 {
128         struct db8500_thermal_zone *th = irq_data;
129         unsigned int idx = th->cur_index;
130         unsigned long next_low, next_high;
131         int num_points = ARRAY_SIZE(db8500_thermal_points);
132
133         if (idx < num_points - 1) {
134                 next_high = db8500_thermal_points[idx+1];
135                 next_low = db8500_thermal_points[idx];
136                 idx += 1;
137
138                 db8500_thermal_update_config(th, idx, next_low, next_high);
139
140                 dev_dbg(th->dev,
141                         "PRCMU set max %ld, min %ld\n", next_high, next_low);
142         } else if (idx == num_points - 1)
143                 /* So we roof out 1 degree over the max point */
144                 th->interpolated_temp = db8500_thermal_points[idx] + 1;
145
146         thermal_zone_device_update(th->tz, THERMAL_EVENT_UNSPECIFIED);
147
148         return IRQ_HANDLED;
149 }
150
151 static int db8500_thermal_probe(struct platform_device *pdev)
152 {
153         struct db8500_thermal_zone *th = NULL;
154         struct device *dev = &pdev->dev;
155         int low_irq, high_irq, ret = 0;
156
157         th = devm_kzalloc(dev, sizeof(*th), GFP_KERNEL);
158         if (!th)
159                 return -ENOMEM;
160
161         th->dev = dev;
162
163         low_irq = platform_get_irq_byname(pdev, "IRQ_HOTMON_LOW");
164         if (low_irq < 0)
165                 return low_irq;
166
167         ret = devm_request_threaded_irq(dev, low_irq, NULL,
168                 prcmu_low_irq_handler, IRQF_NO_SUSPEND | IRQF_ONESHOT,
169                 "dbx500_temp_low", th);
170         if (ret < 0) {
171                 dev_err(dev, "failed to allocate temp low irq\n");
172                 return ret;
173         }
174
175         high_irq = platform_get_irq_byname(pdev, "IRQ_HOTMON_HIGH");
176         if (high_irq < 0)
177                 return high_irq;
178
179         ret = devm_request_threaded_irq(dev, high_irq, NULL,
180                 prcmu_high_irq_handler, IRQF_NO_SUSPEND | IRQF_ONESHOT,
181                 "dbx500_temp_high", th);
182         if (ret < 0) {
183                 dev_err(dev, "failed to allocate temp high irq\n");
184                 return ret;
185         }
186
187         /* register of thermal sensor and get info from DT */
188         th->tz = devm_thermal_of_zone_register(dev, 0, th, &thdev_ops);
189         if (IS_ERR(th->tz)) {
190                 dev_err(dev, "register thermal zone sensor failed\n");
191                 return PTR_ERR(th->tz);
192         }
193         dev_info(dev, "thermal zone sensor registered\n");
194
195         /* Start measuring at the lowest point */
196         db8500_thermal_update_config(th, 0, PRCMU_DEFAULT_LOW_TEMP,
197                                      db8500_thermal_points[0]);
198
199         platform_set_drvdata(pdev, th);
200
201         return 0;
202 }
203
204 static int db8500_thermal_suspend(struct platform_device *pdev,
205                 pm_message_t state)
206 {
207         prcmu_stop_temp_sense();
208
209         return 0;
210 }
211
212 static int db8500_thermal_resume(struct platform_device *pdev)
213 {
214         struct db8500_thermal_zone *th = platform_get_drvdata(pdev);
215
216         /* Resume and start measuring at the lowest point */
217         db8500_thermal_update_config(th, 0, PRCMU_DEFAULT_LOW_TEMP,
218                                      db8500_thermal_points[0]);
219
220         return 0;
221 }
222
223 static const struct of_device_id db8500_thermal_match[] = {
224         { .compatible = "stericsson,db8500-thermal" },
225         {},
226 };
227 MODULE_DEVICE_TABLE(of, db8500_thermal_match);
228
229 static struct platform_driver db8500_thermal_driver = {
230         .driver = {
231                 .name = "db8500-thermal",
232                 .of_match_table = db8500_thermal_match,
233         },
234         .probe = db8500_thermal_probe,
235         .suspend = db8500_thermal_suspend,
236         .resume = db8500_thermal_resume,
237 };
238
239 module_platform_driver(db8500_thermal_driver);
240
241 MODULE_AUTHOR("Hongbo Zhang <hongbo.zhang@stericsson.com>");
242 MODULE_DESCRIPTION("DB8500 thermal driver");
243 MODULE_LICENSE("GPL");