Merge branch 'nohz/printk-v8' into irq/core
[platform/adaptation/renesas_rcar/renesas_kernel.git] / drivers / scsi / Kconfig
1 menu "SCSI device support"
2
3 config SCSI_MOD
4        tristate
5        default y if SCSI=n || SCSI=y
6        default m if SCSI=m
7
8 config RAID_ATTRS
9         tristate "RAID Transport Class"
10         default n
11         depends on BLOCK
12         depends on SCSI_MOD
13         ---help---
14           Provides RAID
15
16 config SCSI
17         tristate "SCSI device support"
18         depends on BLOCK
19         select SCSI_DMA if HAS_DMA
20         ---help---
21           If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
22           any other SCSI device under Linux, say Y and make sure that you know
23           the name of your SCSI host adapter (the card inside your computer
24           that "speaks" the SCSI protocol, also called SCSI controller),
25           because you will be asked for it.
26
27           You also need to say Y here if you have a device which speaks
28           the SCSI protocol.  Examples of this include the parallel port
29           version of the IOMEGA ZIP drive, USB storage devices, Fibre
30           Channel, and FireWire storage.
31
32           To compile this driver as a module, choose M here and read
33           <file:Documentation/scsi/scsi.txt>.
34           The module will be called scsi_mod.
35
36           However, do not compile this as a module if your root file system
37           (the one containing the directory /) is located on a SCSI device.
38
39 config SCSI_DMA
40         bool
41         default n
42
43 config SCSI_TGT
44         tristate "SCSI target support"
45         depends on SCSI && EXPERIMENTAL
46         ---help---
47           If you want to use SCSI target mode drivers enable this option.
48           If you choose M, the module will be called scsi_tgt.
49
50 config SCSI_NETLINK
51         bool
52         default n
53         select NET
54
55 config SCSI_PROC_FS
56         bool "legacy /proc/scsi/ support"
57         depends on SCSI && PROC_FS
58         default y
59         ---help---
60           This option enables support for the various files in
61           /proc/scsi.  In Linux 2.6 this has been superseded by
62           files in sysfs but many legacy applications rely on this.
63
64           If unsure say Y.
65
66 comment "SCSI support type (disk, tape, CD-ROM)"
67         depends on SCSI
68
69 config BLK_DEV_SD
70         tristate "SCSI disk support"
71         depends on SCSI
72         select CRC_T10DIF if BLK_DEV_INTEGRITY
73         ---help---
74           If you want to use SCSI hard disks, Fibre Channel disks,
75           Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
76           USB storage or the SCSI or parallel port version of
77           the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
78           the Disk-HOWTO and the Multi-Disk-HOWTO, available from
79           <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
80           CD-ROMs.
81
82           To compile this driver as a module, choose M here and read
83           <file:Documentation/scsi/scsi.txt>.
84           The module will be called sd_mod.
85
86           Do not compile this driver as a module if your root file system
87           (the one containing the directory /) is located on a SCSI disk.
88           In this case, do not compile the driver for your SCSI host adapter
89           (below) as a module either.
90
91 config CHR_DEV_ST
92         tristate "SCSI tape support"
93         depends on SCSI
94         ---help---
95           If you want to use a SCSI tape drive under Linux, say Y and read the
96           SCSI-HOWTO, available from
97           <http://www.tldp.org/docs.html#howto>, and
98           <file:Documentation/scsi/st.txt> in the kernel source.  This is NOT
99           for SCSI CD-ROMs.
100
101           To compile this driver as a module, choose M here and read
102           <file:Documentation/scsi/scsi.txt>. The module will be called st.
103
104 config CHR_DEV_OSST
105         tristate "SCSI OnStream SC-x0 tape support"
106         depends on SCSI
107         ---help---
108           The OnStream SC-x0 SCSI tape drives cannot be driven by the
109           standard st driver, but instead need this special osst driver and
110           use the  /dev/osstX char device nodes (major 206).  Via usb-storage,
111           you may be able to drive the USB-x0 and DI-x0 drives as well.
112           Note that there is also a second generation of OnStream
113           tape drives (ADR-x0) that supports the standard SCSI-2 commands for
114           tapes (QIC-157) and can be driven by the standard driver st.
115           For more information, you may have a look at the SCSI-HOWTO
116           <http://www.tldp.org/docs.html#howto>  and
117           <file:Documentation/scsi/osst.txt>  in the kernel source.
118           More info on the OnStream driver may be found on
119           <http://sourceforge.net/projects/osst/>
120           Please also have a look at the standard st docu, as most of it
121           applies to osst as well.
122
123           To compile this driver as a module, choose M here and read
124           <file:Documentation/scsi/scsi.txt>. The module will be called osst.
125
126 config BLK_DEV_SR
127         tristate "SCSI CDROM support"
128         depends on SCSI
129         ---help---
130           If you want to use a CD or DVD drive attached to your computer
131           by SCSI, FireWire, USB or ATAPI, say Y and read the SCSI-HOWTO
132           and the CDROM-HOWTO at <http://www.tldp.org/docs.html#howto>.
133
134           Make sure to say Y or M to "ISO 9660 CD-ROM file system support".
135
136           To compile this driver as a module, choose M here and read
137           <file:Documentation/scsi/scsi.txt>.
138           The module will be called sr_mod.
139
140 config BLK_DEV_SR_VENDOR
141         bool "Enable vendor-specific extensions (for SCSI CDROM)"
142         depends on BLK_DEV_SR
143         help
144           This enables the usage of vendor specific SCSI commands. This is
145           required to support multisession CDs with old NEC/TOSHIBA cdrom
146           drives (and HP Writers). If you have such a drive and get the first
147           session only, try saying Y here; everybody else says N.
148
149 config CHR_DEV_SG
150         tristate "SCSI generic support"
151         depends on SCSI
152         ---help---
153           If you want to use SCSI scanners, synthesizers or CD-writers or just
154           about anything having "SCSI" in its name other than hard disks,
155           CD-ROMs or tapes, say Y here. These won't be supported by the kernel
156           directly, so you need some additional software which knows how to
157           talk to these devices using the SCSI protocol:
158
159           For scanners, look at SANE (<http://www.sane-project.org/>). For CD
160           writer software look at Cdrtools
161           (<http://cdrecord.berlios.de/private/cdrecord.html>)
162           and for burning a "disk at once": CDRDAO
163           (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
164           quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
165           For other devices, it's possible that you'll have to write the
166           driver software yourself. Please read the file
167           <file:Documentation/scsi/scsi-generic.txt> for more information.
168
169           To compile this driver as a module, choose M here and read
170           <file:Documentation/scsi/scsi.txt>. The module will be called sg.
171
172           If unsure, say N.
173
174 config CHR_DEV_SCH
175         tristate "SCSI media changer support"
176         depends on SCSI
177         ---help---
178           This is a driver for SCSI media changers.  Most common devices are
179           tape libraries and MOD/CDROM jukeboxes.  *Real* jukeboxes, you
180           don't need this for those tiny 6-slot cdrom changers.  Media
181           changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
182           If you have such hardware and want to use it with linux, say Y
183           here.  Check <file:Documentation/scsi/scsi-changer.txt> for details.
184         
185           If you want to compile this as a module ( = code which can be
186           inserted in and removed from the running kernel whenever you want),
187           say M here and read <file:Documentation/kbuild/modules.txt> and
188           <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
189           If unsure, say N.
190
191 config SCSI_ENCLOSURE
192         tristate "SCSI Enclosure Support"
193         depends on SCSI && ENCLOSURE_SERVICES
194         help
195           Enclosures are devices sitting on or in SCSI backplanes that
196           manage devices.  If you have a disk cage, the chances are that
197           it has an enclosure device.  Selecting this option will just allow
198           certain enclosure conditions to be reported and is not required.
199
200 config SCSI_MULTI_LUN
201         bool "Probe all LUNs on each SCSI device"
202         depends on SCSI
203         help
204           Some devices support more than one LUN (Logical Unit Number) in order
205           to allow access to several media, e.g. CD jukebox, USB card reader,
206           mobile phone in mass storage mode. This option forces the kernel to
207           probe for all LUNs by default. This setting can be overriden by
208           max_luns boot/module parameter. Note that this option does not affect
209           devices conforming to SCSI-3 or higher as they can explicitely report
210           their number of LUNs. It is safe to say Y here unless you have one of
211           those rare devices which reacts in an unexpected way when probed for
212           multiple LUNs.
213
214 config SCSI_CONSTANTS
215         bool "Verbose SCSI error reporting (kernel size +=12K)"
216         depends on SCSI
217         help
218           The error messages regarding your SCSI hardware will be easier to
219           understand if you say Y here; it will enlarge your kernel by about
220           12 KB. If in doubt, say Y.
221
222 config SCSI_LOGGING
223         bool "SCSI logging facility"
224         depends on SCSI
225         ---help---
226           This turns on a logging facility that can be used to debug a number
227           of SCSI related problems.
228
229           If you say Y here, no logging output will appear by default, but you
230           can enable logging by saying Y to "/proc file system support" and
231           "Sysctl support" below and executing the command
232
233           echo <bitmask> > /proc/sys/dev/scsi/logging_level
234
235           where <bitmask> is a four byte value representing the logging type
236           and logging level for each type of logging selected.
237
238           There are a number of logging types and you can find them in the
239           source at <file:drivers/scsi/scsi_logging.h>. The logging levels
240           are also described in that file and they determine the verbosity of
241           the logging for each logging type.
242
243           If you say N here, it may be harder to track down some types of SCSI
244           problems. If you say Y here your kernel will be somewhat larger, but
245           there should be no noticeable performance impact as long as you have
246           logging turned off.
247
248 config SCSI_SCAN_ASYNC
249         bool "Asynchronous SCSI scanning"
250         depends on SCSI
251         help
252           The SCSI subsystem can probe for devices while the rest of the
253           system continues booting, and even probe devices on different
254           busses in parallel, leading to a significant speed-up.
255
256           If you have built SCSI as modules, enabling this option can
257           be a problem as the devices may not have been found by the
258           time your system expects them to have been.  You can load the
259           scsi_wait_scan module to ensure that all scans have completed.
260           If you build your SCSI drivers into the kernel, then everything
261           will work fine if you say Y here.
262
263           You can override this choice by specifying "scsi_mod.scan=sync"
264           or async on the kernel's command line.
265
266 menu "SCSI Transports"
267         depends on SCSI
268
269 config SCSI_SPI_ATTRS
270         tristate "Parallel SCSI (SPI) Transport Attributes"
271         depends on SCSI
272         help
273           If you wish to export transport-specific information about
274           each attached SCSI device to sysfs, say Y.  Otherwise, say N.
275
276 config SCSI_FC_ATTRS
277         tristate "FiberChannel Transport Attributes"
278         depends on SCSI
279         select SCSI_NETLINK
280         help
281           If you wish to export transport-specific information about
282           each attached FiberChannel device to sysfs, say Y.
283           Otherwise, say N.
284
285 config SCSI_FC_TGT_ATTRS
286         bool "SCSI target support for FiberChannel Transport Attributes"
287         depends on SCSI_FC_ATTRS
288         depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
289         help
290                 If you want to use SCSI target mode drivers enable this option.
291
292 config SCSI_ISCSI_ATTRS
293         tristate "iSCSI Transport Attributes"
294         depends on SCSI && NET
295         select BLK_DEV_BSGLIB
296         help
297           If you wish to export transport-specific information about
298           each attached iSCSI device to sysfs, say Y.
299           Otherwise, say N.
300
301 config SCSI_SAS_ATTRS
302         tristate "SAS Transport Attributes"
303         depends on SCSI
304         select BLK_DEV_BSG
305         help
306           If you wish to export transport-specific information about
307           each attached SAS device to sysfs, say Y.
308
309 source "drivers/scsi/libsas/Kconfig"
310
311 config SCSI_SRP_ATTRS
312         tristate "SRP Transport Attributes"
313         depends on SCSI
314         help
315           If you wish to export transport-specific information about
316           each attached SRP device to sysfs, say Y.
317
318 config SCSI_SRP_TGT_ATTRS
319         bool "SCSI target support for SRP Transport Attributes"
320         depends on SCSI_SRP_ATTRS
321         depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
322         help
323                 If you want to use SCSI target mode drivers enable this option.
324
325 endmenu
326
327 menuconfig SCSI_LOWLEVEL
328         bool "SCSI low-level drivers"
329         depends on SCSI!=n
330         default y
331
332 if SCSI_LOWLEVEL && SCSI
333
334 config ISCSI_TCP
335         tristate "iSCSI Initiator over TCP/IP"
336         depends on SCSI && INET
337         select CRYPTO
338         select CRYPTO_MD5
339         select CRYPTO_CRC32C
340         select SCSI_ISCSI_ATTRS
341         help
342          The iSCSI Driver provides a host with the ability to access storage
343          through an IP network. The driver uses the iSCSI protocol to transport
344          SCSI requests and responses over a TCP/IP network between the host
345          (the "initiator") and "targets".  Architecturally, the iSCSI driver
346          combines with the host's TCP/IP stack, network drivers, and Network
347          Interface Card (NIC) to provide the same functions as a SCSI or a
348          Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
349
350          To compile this driver as a module, choose M here: the
351          module will be called iscsi_tcp.
352
353          The userspace component needed to initialize the driver, documentation,
354          and sample configuration files can be found here:
355
356          http://open-iscsi.org
357
358 config ISCSI_BOOT_SYSFS
359         tristate "iSCSI Boot Sysfs Interface"
360         default n
361         help
362           This option enables support for exposing iSCSI boot information
363           via sysfs to userspace. If you wish to export this information,
364           say Y. Otherwise, say N.
365
366 source "drivers/scsi/cxgbi/Kconfig"
367 source "drivers/scsi/bnx2i/Kconfig"
368 source "drivers/scsi/bnx2fc/Kconfig"
369 source "drivers/scsi/be2iscsi/Kconfig"
370
371 config SGIWD93_SCSI
372         tristate "SGI WD93C93 SCSI Driver"
373         depends on SGI_HAS_WD93 && SCSI
374         help
375           If you have a Western Digital WD93 SCSI controller on
376           an SGI MIPS system, say Y.  Otherwise, say N.
377
378 config BLK_DEV_3W_XXXX_RAID
379         tristate "3ware 5/6/7/8xxx ATA-RAID support"
380         depends on PCI && SCSI
381         help
382           3ware is the only hardware ATA-Raid product in Linux to date.
383           This card is 2,4, or 8 channel master mode support only.
384           SCSI support required!!!
385
386           <http://www.3ware.com/>
387
388           Please read the comments at the top of
389           <file:drivers/scsi/3w-xxxx.c>.
390
391 config SCSI_HPSA
392         tristate "HP Smart Array SCSI driver"
393         depends on PCI && SCSI
394         select CHECK_SIGNATURE
395         help
396           This driver supports HP Smart Array Controllers (circa 2009).
397           It is a SCSI alternative to the cciss driver, which is a block
398           driver.  Anyone wishing to use HP Smart Array controllers who
399           would prefer the devices be presented to linux as SCSI devices,
400           rather than as generic block devices should say Y here.
401
402 config SCSI_3W_9XXX
403         tristate "3ware 9xxx SATA-RAID support"
404         depends on PCI && SCSI
405         help
406           This driver supports the 9000 series 3ware SATA-RAID cards.
407
408           <http://www.amcc.com>
409
410           Please read the comments at the top of
411           <file:drivers/scsi/3w-9xxx.c>.
412
413 config SCSI_3W_SAS
414         tristate "3ware 97xx SAS/SATA-RAID support"
415         depends on PCI && SCSI
416         help
417           This driver supports the LSI 3ware 9750 6Gb/s SAS/SATA-RAID cards.
418
419           <http://www.lsi.com>
420
421           Please read the comments at the top of
422           <file:drivers/scsi/3w-sas.c>.
423
424 config SCSI_7000FASST
425         tristate "7000FASST SCSI support"
426         depends on ISA && SCSI && ISA_DMA_API
427         select CHECK_SIGNATURE
428         help
429           This driver supports the Western Digital 7000 SCSI host adapter
430           family.  Some information is in the source:
431           <file:drivers/scsi/wd7000.c>.
432
433           To compile this driver as a module, choose M here: the
434           module will be called wd7000.
435
436 config SCSI_ACARD
437         tristate "ACARD SCSI support"
438         depends on PCI && SCSI
439         help
440           This driver supports the ACARD SCSI host adapter.
441           Support Chip <ATP870 ATP876 ATP880 ATP885>
442           To compile this driver as a module, choose M here: the
443           module will be called atp870u.
444
445 config SCSI_AHA152X
446         tristate "Adaptec AHA152X/2825 support"
447         depends on ISA && SCSI
448         select SCSI_SPI_ATTRS
449         select CHECK_SIGNATURE
450         ---help---
451           This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
452           SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
453           must be manually specified in this case.
454
455           It is explained in section 3.3 of the SCSI-HOWTO, available from
456           <http://www.tldp.org/docs.html#howto>. You might also want to
457           read the file <file:Documentation/scsi/aha152x.txt>.
458
459           To compile this driver as a module, choose M here: the
460           module will be called aha152x.
461
462 config SCSI_AHA1542
463         tristate "Adaptec AHA1542 support"
464         depends on ISA && SCSI && ISA_DMA_API
465         ---help---
466           This is support for a SCSI host adapter.  It is explained in section
467           3.4 of the SCSI-HOWTO, available from
468           <http://www.tldp.org/docs.html#howto>.  Note that Trantor was
469           purchased by Adaptec, and some former Trantor products are being
470           sold under the Adaptec name.  If it doesn't work out of the box, you
471           may have to change some settings in <file:drivers/scsi/aha1542.h>.
472
473           To compile this driver as a module, choose M here: the
474           module will be called aha1542.
475
476 config SCSI_AHA1740
477         tristate "Adaptec AHA1740 support"
478         depends on EISA && SCSI
479         ---help---
480           This is support for a SCSI host adapter.  It is explained in section
481           3.5 of the SCSI-HOWTO, available from
482           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
483           of the box, you may have to change some settings in
484           <file:drivers/scsi/aha1740.h>.
485
486           To compile this driver as a module, choose M here: the
487           module will be called aha1740.
488
489 config SCSI_AACRAID
490         tristate "Adaptec AACRAID support"
491         depends on SCSI && PCI
492         help
493           This driver supports a variety of Dell, HP, Adaptec, IBM and
494           ICP storage products. For a list of supported products, refer
495           to <file:Documentation/scsi/aacraid.txt>.
496
497           To compile this driver as a module, choose M here: the module
498           will be called aacraid.
499
500
501 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
502
503 config SCSI_AIC7XXX_OLD
504         tristate "Adaptec AIC7xxx support (old driver)"
505         depends on (ISA || EISA || PCI ) && SCSI
506         help
507           WARNING This driver is an older aic7xxx driver and is no longer
508           under active development.  Adaptec, Inc. is writing a new driver to
509           take the place of this one, and it is recommended that whenever
510           possible, people should use the new Adaptec written driver instead
511           of this one.  This driver will eventually be phased out entirely.
512
513           This is support for the various aic7xxx based Adaptec SCSI
514           controllers. These include the 274x EISA cards; 284x VLB cards;
515           2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
516           motherboard based SCSI controllers from Adaptec. It does not support
517           the AAA-13x RAID controllers from Adaptec, nor will it likely ever
518           support them. It does not support the 2920 cards from Adaptec that
519           use the Future Domain SCSI controller chip. For those cards, you
520           need the "Future Domain 16xx SCSI support" driver.
521
522           In general, if the controller is based on an Adaptec SCSI controller
523           chip from the aic777x series or the aic78xx series, this driver
524           should work. The only exception is the 7810 which is specifically
525           not supported (that's the RAID controller chip on the AAA-13x
526           cards).
527
528           Note that the AHA2920 SCSI host adapter is *not* supported by this
529           driver; choose "Future Domain 16xx SCSI support" instead if you have
530           one of those.
531
532           Information on the configuration options for this controller can be
533           found by checking the help file for each of the available
534           configuration options. You should read
535           <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
536           contacting the maintainer with any questions.  The SCSI-HOWTO,
537           available from <http://www.tldp.org/docs.html#howto>, can also
538           be of great help.
539
540           To compile this driver as a module, choose M here: the
541           module will be called aic7xxx_old.
542
543 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
544 source "drivers/scsi/aic94xx/Kconfig"
545 source "drivers/scsi/mvsas/Kconfig"
546
547 config SCSI_MVUMI
548         tristate "Marvell UMI driver"
549         depends on SCSI && PCI
550         help
551           Module for Marvell Universal Message Interface(UMI) driver
552
553           To compile this driver as a module, choose M here: the
554           module will be called mvumi.
555
556 config SCSI_DPT_I2O
557         tristate "Adaptec I2O RAID support "
558         depends on SCSI && PCI && VIRT_TO_BUS
559         help
560           This driver supports all of Adaptec's I2O based RAID controllers as 
561           well as the DPT SmartRaid V cards.  This is an Adaptec maintained
562           driver by Deanna Bonds.  See <file:Documentation/scsi/dpti.txt>.
563
564           To compile this driver as a module, choose M here: the
565           module will be called dpt_i2o.
566
567 config SCSI_ADVANSYS
568         tristate "AdvanSys SCSI support"
569         depends on SCSI && VIRT_TO_BUS
570         depends on ISA || EISA || PCI
571         help
572           This is a driver for all SCSI host adapters manufactured by
573           AdvanSys. It is documented in the kernel source in
574           <file:drivers/scsi/advansys.c>.
575
576           To compile this driver as a module, choose M here: the
577           module will be called advansys.
578
579 config SCSI_IN2000
580         tristate "Always IN2000 SCSI support"
581         depends on ISA && SCSI
582         help
583           This is support for an ISA bus SCSI host adapter.  You'll find more
584           information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
585           out of the box, you may have to change the jumpers for IRQ or
586           address selection.
587
588           To compile this driver as a module, choose M here: the
589           module will be called in2000.
590
591 config SCSI_ARCMSR
592         tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
593         depends on PCI && SCSI
594         help
595           This driver supports all of ARECA's SATA/SAS RAID controller cards.
596           This is an ARECA-maintained driver by Erich Chen.
597           If you have any problems, please mail to: <erich@areca.com.tw>.
598           Areca supports Linux RAID config tools.
599           Please link <http://www.areca.com.tw>
600
601           To compile this driver as a module, choose M here: the
602           module will be called arcmsr (modprobe arcmsr).
603
604 source "drivers/scsi/megaraid/Kconfig.megaraid"
605 source "drivers/scsi/mpt2sas/Kconfig"
606 source "drivers/scsi/mpt3sas/Kconfig"
607 source "drivers/scsi/ufs/Kconfig"
608
609 config SCSI_HPTIOP
610         tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
611         depends on SCSI && PCI
612         help
613           This option enables support for HighPoint RocketRAID 3xxx/4xxx
614           controllers.
615
616           To compile this driver as a module, choose M here; the module
617           will be called hptiop. If unsure, say N.
618
619 config SCSI_BUSLOGIC
620         tristate "BusLogic SCSI support"
621         depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
622         ---help---
623           This is support for BusLogic MultiMaster and FlashPoint SCSI Host
624           Adapters. Consult the SCSI-HOWTO, available from
625           <http://www.tldp.org/docs.html#howto>, and the files
626           <file:Documentation/scsi/BusLogic.txt> and
627           <file:Documentation/scsi/FlashPoint.txt> for more information.
628           Note that support for FlashPoint is only available for 32-bit
629           x86 configurations.
630
631           To compile this driver as a module, choose M here: the
632           module will be called BusLogic.
633
634 config SCSI_FLASHPOINT
635         bool "FlashPoint support"
636         depends on SCSI_BUSLOGIC && PCI && X86_32
637         help
638           This option allows you to add FlashPoint support to the
639           BusLogic SCSI driver. The FlashPoint SCCB Manager code is
640           substantial, so users of MultiMaster Host Adapters may not
641           wish to include it.
642
643 config VMWARE_PVSCSI
644         tristate "VMware PVSCSI driver support"
645         depends on PCI && SCSI && X86
646         help
647           This driver supports VMware's para virtualized SCSI HBA.
648           To compile this driver as a module, choose M here: the
649           module will be called vmw_pvscsi.
650
651 config HYPERV_STORAGE
652         tristate "Microsoft Hyper-V virtual storage driver"
653         depends on SCSI && HYPERV
654         default HYPERV
655         help
656           Select this option to enable the Hyper-V virtual storage driver.
657
658 config LIBFC
659         tristate "LibFC module"
660         select SCSI_FC_ATTRS
661         select CRC32
662         ---help---
663           Fibre Channel library module
664
665 config LIBFCOE
666         tristate "LibFCoE module"
667         select LIBFC
668         ---help---
669           Library for Fibre Channel over Ethernet module
670
671 config FCOE
672         tristate "FCoE module"
673         depends on PCI
674         select LIBFCOE
675         ---help---
676           Fibre Channel over Ethernet module
677
678 config FCOE_FNIC
679         tristate "Cisco FNIC Driver"
680         depends on PCI && X86
681         select LIBFCOE
682         help
683           This is support for the Cisco PCI-Express FCoE HBA.
684
685           To compile this driver as a module, choose M here and read
686           <file:Documentation/scsi/scsi.txt>.
687           The module will be called fnic.
688
689 config SCSI_DMX3191D
690         tristate "DMX3191D SCSI support"
691         depends on PCI && SCSI
692         select SCSI_SPI_ATTRS
693         help
694           This is support for Domex DMX3191D SCSI Host Adapters.
695
696           To compile this driver as a module, choose M here: the
697           module will be called dmx3191d.
698
699 config SCSI_DTC3280
700         tristate "DTC3180/3280 SCSI support"
701         depends on ISA && SCSI
702         select SCSI_SPI_ATTRS
703         select CHECK_SIGNATURE
704         help
705           This is support for DTC 3180/3280 SCSI Host Adapters.  Please read
706           the SCSI-HOWTO, available from
707           <http://www.tldp.org/docs.html#howto>, and the file
708           <file:Documentation/scsi/dtc3x80.txt>.
709
710           To compile this driver as a module, choose M here: the
711           module will be called dtc.
712
713 config SCSI_EATA
714         tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
715         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
716         ---help---
717           This driver supports all EATA/DMA-compliant SCSI host adapters.  DPT
718           ISA and all EISA I/O addresses are probed looking for the "EATA"
719           signature. The addresses of all the PCI SCSI controllers reported
720           by the PCI subsystem are probed as well.
721
722           You want to read the start of <file:drivers/scsi/eata.c> and the
723           SCSI-HOWTO, available from
724           <http://www.tldp.org/docs.html#howto>.
725
726           To compile this driver as a module, choose M here: the
727           module will be called eata.
728
729 config SCSI_EATA_TAGGED_QUEUE
730         bool "enable tagged command queueing"
731         depends on SCSI_EATA
732         help
733           This is a feature of SCSI-2 which improves performance: the host
734           adapter can send several SCSI commands to a device's queue even if
735           previous commands haven't finished yet.
736           This is equivalent to the "eata=tc:y" boot option.
737
738 config SCSI_EATA_LINKED_COMMANDS
739         bool "enable elevator sorting"
740         depends on SCSI_EATA
741         help
742           This option enables elevator sorting for all probed SCSI disks and
743           CD-ROMs. It definitely reduces the average seek distance when doing
744           random seeks, but this does not necessarily result in a noticeable
745           performance improvement: your mileage may vary...
746           This is equivalent to the "eata=lc:y" boot option.
747
748 config SCSI_EATA_MAX_TAGS
749         int "maximum number of queued commands"
750         depends on SCSI_EATA
751         default "16"
752         help
753           This specifies how many SCSI commands can be maximally queued for
754           each probed SCSI device. You should reduce the default value of 16
755           only if you have disks with buggy or limited tagged command support.
756           Minimum is 2 and maximum is 62. This value is also the window size
757           used by the elevator sorting option above. The effective value used
758           by the driver for each probed SCSI device is reported at boot time.
759           This is equivalent to the "eata=mq:8" boot option.
760
761 config SCSI_EATA_PIO
762         tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
763         depends on (ISA || EISA || PCI) && SCSI && BROKEN
764         ---help---
765           This driver supports all EATA-PIO protocol compliant SCSI Host
766           Adapters like the DPT PM2001 and the PM2012A.  EATA-DMA compliant
767           host adapters could also use this driver but are discouraged from
768           doing so, since this driver only supports hard disks and lacks
769           numerous features.  You might want to have a look at the SCSI-HOWTO,
770           available from <http://www.tldp.org/docs.html#howto>.
771
772           To compile this driver as a module, choose M here: the
773           module will be called eata_pio.
774
775 config SCSI_FUTURE_DOMAIN
776         tristate "Future Domain 16xx SCSI/AHA-2920A support"
777         depends on (ISA || PCI) && SCSI
778         select CHECK_SIGNATURE
779         ---help---
780           This is support for Future Domain's 16-bit SCSI host adapters
781           (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
782           other adapters based on the Future Domain chipsets (Quantum
783           ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
784           It is explained in section 3.7 of the SCSI-HOWTO, available from
785           <http://www.tldp.org/docs.html#howto>.
786
787           NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
788           and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
789           controller support"). This Future Domain driver works with the older
790           Adaptec AHA-2920A boards with a Future Domain chip on them.
791
792           To compile this driver as a module, choose M here: the
793           module will be called fdomain.
794
795 config SCSI_GDTH
796         tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
797         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
798         ---help---
799           Formerly called GDT SCSI Disk Array Controller Support.
800
801           This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI) 
802           manufactured by Intel Corporation/ICP vortex GmbH. It is documented
803           in the kernel source in <file:drivers/scsi/gdth.c> and
804           <file:drivers/scsi/gdth.h>.
805
806           To compile this driver as a module, choose M here: the
807           module will be called gdth.
808
809 config SCSI_ISCI
810         tristate "Intel(R) C600 Series Chipset SAS Controller"
811         depends on PCI && SCSI
812         depends on X86
813         select SCSI_SAS_LIBSAS
814         ---help---
815           This driver supports the 6Gb/s SAS capabilities of the storage
816           control unit found in the Intel(R) C600 series chipset.
817
818 config SCSI_GENERIC_NCR5380
819         tristate "Generic NCR5380/53c400 SCSI PIO support"
820         depends on ISA && SCSI
821         select SCSI_SPI_ATTRS
822         ---help---
823           This is a driver for the old NCR 53c80 series of SCSI controllers
824           on boards using PIO. Most boards such as the Trantor T130 fit this
825           category, along with a large number of ISA 8bit controllers shipped
826           for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
827           you should select the specific driver for that card rather than
828           generic 5380 support.
829
830           It is explained in section 3.8 of the SCSI-HOWTO, available from
831           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
832           of the box, you may have to change some settings in
833           <file:drivers/scsi/g_NCR5380.h>.
834
835           To compile this driver as a module, choose M here: the
836           module will be called g_NCR5380.
837
838 config SCSI_GENERIC_NCR5380_MMIO
839         tristate "Generic NCR5380/53c400 SCSI MMIO support"
840         depends on ISA && SCSI
841         select SCSI_SPI_ATTRS
842         ---help---
843           This is a driver for the old NCR 53c80 series of SCSI controllers
844           on boards using memory mapped I/O. 
845           It is explained in section 3.8 of the SCSI-HOWTO, available from
846           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
847           of the box, you may have to change some settings in
848           <file:drivers/scsi/g_NCR5380.h>.
849
850           To compile this driver as a module, choose M here: the
851           module will be called g_NCR5380_mmio.
852
853 config SCSI_GENERIC_NCR53C400
854         bool "Enable NCR53c400 extensions"
855         depends on SCSI_GENERIC_NCR5380
856         help
857           This enables certain optimizations for the NCR53c400 SCSI cards.
858           You might as well try it out.  Note that this driver will only probe
859           for the Trantor T130B in its default configuration; you might have
860           to pass a command line option to the kernel at boot time if it does
861           not detect your card.  See the file
862           <file:Documentation/scsi/g_NCR5380.txt> for details.
863
864 config SCSI_IPS
865         tristate "IBM ServeRAID support"
866         depends on PCI && SCSI
867         ---help---
868           This is support for the IBM ServeRAID hardware RAID controllers.
869           See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
870           and <http://www-947.ibm.com/support/entry/portal/docdisplay?brand=5000008&lndocid=SERV-RAID>
871           for more information.  If this driver does not work correctly
872           without modification please contact the author by email at
873           <ipslinux@adaptec.com>.
874
875           To compile this driver as a module, choose M here: the
876           module will be called ips.
877
878 config SCSI_IBMVSCSI
879         tristate "IBM Virtual SCSI support"
880         depends on PPC_PSERIES
881         select SCSI_SRP_ATTRS
882         help
883           This is the IBM POWER Virtual SCSI Client
884
885           To compile this driver as a module, choose M here: the
886           module will be called ibmvscsic.
887
888 config SCSI_IBMVSCSIS
889         tristate "IBM Virtual SCSI Server support"
890         depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
891         help
892           This is the SRP target driver for IBM pSeries virtual environments.
893
894           The userspace component needed to initialize the driver and
895           documentation can be found:
896
897           http://stgt.berlios.de/
898
899           To compile this driver as a module, choose M here: the
900           module will be called ibmvstgt.
901
902 config SCSI_IBMVFC
903         tristate "IBM Virtual FC support"
904         depends on PPC_PSERIES && SCSI
905         select SCSI_FC_ATTRS
906         help
907           This is the IBM POWER Virtual FC Client
908
909           To compile this driver as a module, choose M here: the
910           module will be called ibmvfc.
911
912 config SCSI_IBMVFC_TRACE
913         bool "enable driver internal trace"
914         depends on SCSI_IBMVFC
915         default y
916         help
917           If you say Y here, the driver will trace all commands issued
918           to the adapter. Performance impact is minimal. Trace can be
919           dumped using /sys/class/scsi_host/hostXX/trace.
920
921 config SCSI_INITIO
922         tristate "Initio 9100U(W) support"
923         depends on PCI && SCSI
924         help
925           This is support for the Initio 91XXU(W) SCSI host adapter.  Please
926           read the SCSI-HOWTO, available from
927           <http://www.tldp.org/docs.html#howto>.
928
929           To compile this driver as a module, choose M here: the
930           module will be called initio.
931
932 config SCSI_INIA100
933         tristate "Initio INI-A100U2W support"
934         depends on PCI && SCSI
935         help
936           This is support for the Initio INI-A100U2W SCSI host adapter.
937           Please read the SCSI-HOWTO, available from
938           <http://www.tldp.org/docs.html#howto>.
939
940           To compile this driver as a module, choose M here: the
941           module will be called a100u2w.
942
943 config SCSI_PPA
944         tristate "IOMEGA parallel port (ppa - older drives)"
945         depends on SCSI && PARPORT_PC
946         ---help---
947           This driver supports older versions of IOMEGA's parallel port ZIP
948           drive (a 100 MB removable media device).
949
950           Note that you can say N here if you have the SCSI version of the ZIP
951           drive: it will be supported automatically if you said Y to the
952           generic "SCSI disk support", above.
953
954           If you have the ZIP Plus drive or a more recent parallel port ZIP
955           drive (if the supplied cable with the drive is labeled "AutoDetect")
956           then you should say N here and Y to "IOMEGA parallel port (imm -
957           newer drives)", below.
958
959           For more information about this driver and how to use it you should
960           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
961           the SCSI-HOWTO, which is available from
962           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
963           you will still be able to use the parallel port for other tasks,
964           such as a printer; it is safe to compile both drivers into the
965           kernel.
966
967           To compile this driver as a module, choose M here: the
968           module will be called ppa.
969
970 config SCSI_IMM
971         tristate "IOMEGA parallel port (imm - newer drives)"
972         depends on SCSI && PARPORT_PC
973         ---help---
974           This driver supports newer versions of IOMEGA's parallel port ZIP
975           drive (a 100 MB removable media device).
976
977           Note that you can say N here if you have the SCSI version of the ZIP
978           drive: it will be supported automatically if you said Y to the
979           generic "SCSI disk support", above.
980
981           If you have the ZIP Plus drive or a more recent parallel port ZIP
982           drive (if the supplied cable with the drive is labeled "AutoDetect")
983           then you should say Y here; if you have an older ZIP drive, say N
984           here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
985
986           For more information about this driver and how to use it you should
987           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
988           the SCSI-HOWTO, which is available from
989           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
990           you will still be able to use the parallel port for other tasks,
991           such as a printer; it is safe to compile both drivers into the
992           kernel.
993
994           To compile this driver as a module, choose M here: the
995           module will be called imm.
996
997 config SCSI_IZIP_EPP16
998         bool "ppa/imm option - Use slow (but safe) EPP-16"
999         depends on SCSI_PPA || SCSI_IMM
1000         ---help---
1001           EPP (Enhanced Parallel Port) is a standard for parallel ports which
1002           allows them to act as expansion buses that can handle up to 64
1003           peripheral devices.
1004
1005           Some parallel port chipsets are slower than their motherboard, and
1006           so we have to control the state of the chipset's FIFO queue every
1007           now and then to avoid data loss. This will be done if you say Y
1008           here.
1009
1010           Generally, saying Y is the safe option and slows things down a bit.
1011
1012 config SCSI_IZIP_SLOW_CTR
1013         bool "ppa/imm option - Assume slow parport control register"
1014         depends on SCSI_PPA || SCSI_IMM
1015         help
1016           Some parallel ports are known to have excessive delays between
1017           changing the parallel port control register and good data being
1018           available on the parallel port data/status register. This option
1019           forces a small delay (1.0 usec to be exact) after changing the
1020           control register to let things settle out. Enabling this option may
1021           result in a big drop in performance but some very old parallel ports
1022           (found in 386 vintage machines) will not work properly.
1023
1024           Generally, saying N is fine.
1025
1026 config SCSI_NCR53C406A
1027         tristate "NCR53c406a SCSI support"
1028         depends on ISA && SCSI
1029         help
1030           This is support for the NCR53c406a SCSI host adapter.  For user
1031           configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
1032           in the kernel source.  Also read the SCSI-HOWTO, available from
1033           <http://www.tldp.org/docs.html#howto>.
1034
1035           To compile this driver as a module, choose M here: the
1036           module will be called NCR53c406.
1037
1038 config SCSI_NCR_D700
1039         tristate "NCR Dual 700 MCA SCSI support"
1040         depends on MCA && SCSI
1041         select SCSI_SPI_ATTRS
1042         help
1043           This is a driver for the MicroChannel Dual 700 card produced by
1044           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1045           tries to negotiate sync and uses tag command queueing.
1046
1047           Unless you have an NCR manufactured machine, the chances are that
1048           you do not have this SCSI card, so say N.
1049
1050 config SCSI_LASI700
1051         tristate "HP Lasi SCSI support for 53c700/710"
1052         depends on GSC && SCSI
1053         select SCSI_SPI_ATTRS
1054         help
1055           This is a driver for the SCSI controller in the Lasi chip found in
1056           many PA-RISC workstations & servers.  If you do not know whether you
1057           have a Lasi chip, it is safe to say "Y" here.
1058
1059 config SCSI_SNI_53C710
1060         tristate "SNI RM SCSI support for 53c710"
1061         depends on SNI_RM && SCSI
1062         select SCSI_SPI_ATTRS
1063         select 53C700_LE_ON_BE
1064         help
1065           This is a driver for the onboard SCSI controller found in older
1066           SNI RM workstations & servers.
1067
1068 config 53C700_LE_ON_BE
1069         bool
1070         depends on SCSI_LASI700
1071         default y
1072
1073 config SCSI_STEX
1074         tristate "Promise SuperTrak EX Series support"
1075         depends on PCI && SCSI
1076         ---help---
1077           This driver supports Promise SuperTrak EX series storage controllers.
1078
1079           Promise provides Linux RAID configuration utility for these
1080           controllers. Please visit <http://www.promise.com> to download.
1081
1082           To compile this driver as a module, choose M here: the
1083           module will be called stex.
1084
1085 config 53C700_BE_BUS
1086         bool
1087         depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
1088         default y
1089
1090 config SCSI_SYM53C8XX_2
1091         tristate "SYM53C8XX Version 2 SCSI support"
1092         depends on PCI && SCSI
1093         select SCSI_SPI_ATTRS
1094         ---help---
1095           This driver supports the whole NCR53C8XX/SYM53C8XX family of
1096           PCI-SCSI controllers.  It also supports the subset of LSI53C10XX
1097           Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
1098           language.  It does not support LSI53C10XX Ultra-320 PCI-X SCSI
1099           controllers; you need to use the Fusion MPT driver for that.
1100
1101           Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
1102           information.
1103
1104 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
1105         int "DMA addressing mode"
1106         depends on SCSI_SYM53C8XX_2
1107         default "1"
1108         ---help---
1109           This option only applies to PCI-SCSI chips that are PCI DAC
1110           capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
1111
1112           When set to 0, the driver will program the chip to only perform
1113           32-bit DMA.  When set to 1, the chip will be able to perform DMA
1114           to addresses up to 1TB.  When set to 2, the driver supports the
1115           full 64-bit DMA address range, but can only address 16 segments
1116           of 4 GB each.  This limits the total addressable range to 64 GB.
1117
1118           Most machines with less than 4GB of memory should use a setting
1119           of 0 for best performance.  If your machine has 4GB of memory
1120           or more, you should set this option to 1 (the default).
1121
1122           The still experimental value 2 (64 bit DMA addressing with 16
1123           x 4GB segments limitation) can be used on systems that require
1124           PCI address bits past bit 39 to be set for the addressing of
1125           memory using PCI DAC cycles.
1126
1127 config SCSI_SYM53C8XX_DEFAULT_TAGS
1128         int "Default tagged command queue depth"
1129         depends on SCSI_SYM53C8XX_2
1130         default "16"
1131         help
1132           This is the default value of the command queue depth the
1133           driver will announce to the generic SCSI layer for devices
1134           that support tagged command queueing. This value can be changed
1135           from the boot command line.  This is a soft limit that cannot
1136           exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
1137
1138 config SCSI_SYM53C8XX_MAX_TAGS
1139         int "Maximum number of queued commands"
1140         depends on SCSI_SYM53C8XX_2
1141         default "64"
1142         help
1143           This option allows you to specify the maximum number of commands
1144           that can be queued to any device, when tagged command queuing is
1145           possible. The driver supports up to 256 queued commands per device.
1146           This value is used as a compiled-in hard limit.
1147
1148 config SCSI_SYM53C8XX_MMIO
1149         bool "Use memory mapped IO"
1150         depends on SCSI_SYM53C8XX_2
1151         default y
1152         help
1153           Memory mapped IO is faster than Port IO.  Most people should
1154           answer Y here, but some machines may have problems.  If you have
1155           to answer N here, please report the problem to the maintainer.
1156
1157 config SCSI_IPR
1158         tristate "IBM Power Linux RAID adapter support"
1159         depends on PCI && SCSI && ATA
1160         select FW_LOADER
1161         ---help---
1162           This driver supports the IBM Power Linux family RAID adapters.
1163           This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1164           as IBM iSeries 5702, 5703, 5709, and 570A.
1165
1166 config SCSI_IPR_TRACE
1167         bool "enable driver internal trace"
1168         depends on SCSI_IPR
1169         default y
1170         help
1171           If you say Y here, the driver will trace all commands issued
1172           to the adapter. Performance impact is minimal. Trace can be
1173           dumped using /sys/bus/class/scsi_host/hostXX/trace.
1174
1175 config SCSI_IPR_DUMP
1176         bool "enable adapter dump support"
1177         depends on SCSI_IPR
1178         default y
1179         help
1180           If you say Y here, the driver will support adapter crash dump.
1181           If you enable this support, the iprdump daemon can be used
1182           to capture adapter failure analysis information.
1183
1184 config SCSI_ZALON
1185         tristate "Zalon SCSI support"
1186         depends on GSC && SCSI
1187         select SCSI_SPI_ATTRS
1188         help
1189           The Zalon is a GSC/HSC bus interface chip that sits between the
1190           PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1191           C110, J200, J210 and some D, K & R-class machines.  It's also
1192           used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1193           Say Y here if you have one of these machines or cards.
1194
1195 config SCSI_NCR_Q720
1196         tristate "NCR Quad 720 MCA SCSI support"
1197         depends on MCA && SCSI
1198         select SCSI_SPI_ATTRS
1199         help
1200           This is a driver for the MicroChannel Quad 720 card produced by
1201           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1202           tries to negotiate sync and uses tag command queueing.
1203
1204           Unless you have an NCR manufactured machine, the chances are that
1205           you do not have this SCSI card, so say N.
1206
1207 config SCSI_NCR53C8XX_DEFAULT_TAGS
1208         int "default tagged command queue depth"
1209         depends on SCSI_ZALON || SCSI_NCR_Q720
1210         default "8"
1211         ---help---
1212           "Tagged command queuing" is a feature of SCSI-2 which improves
1213           performance: the host adapter can send several SCSI commands to a
1214           device's queue even if previous commands haven't finished yet.
1215           Because the device is intelligent, it can optimize its operations
1216           (like head positioning) based on its own request queue. Some SCSI
1217           devices don't implement this properly; if you want to disable this
1218           feature, enter 0 or 1 here (it doesn't matter which).
1219
1220           The default value is 8 and should be supported by most hard disks.
1221           This value can be overridden from the boot command line using the
1222           'tags' option as follows (example):
1223           'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1224           4, set queue depth to 16 for target 2 and target 3 on controller 0
1225           and set queue depth to 10 for target 0 / lun 2 on controller 1.
1226
1227           The normal answer therefore is to go with the default 8 and to use
1228           a boot command line option for devices that need to use a different
1229           command queue depth.
1230
1231           There is no safe option other than using good SCSI devices.
1232
1233 config SCSI_NCR53C8XX_MAX_TAGS
1234         int "maximum number of queued commands"
1235         depends on SCSI_ZALON || SCSI_NCR_Q720
1236         default "32"
1237         ---help---
1238           This option allows you to specify the maximum number of commands
1239           that can be queued to any device, when tagged command queuing is
1240           possible. The default value is 32. Minimum is 2, maximum is 64.
1241           Modern hard disks are able to support 64 tags and even more, but
1242           do not seem to be faster when more than 32 tags are being used.
1243
1244           So, the normal answer here is to go with the default value 32 unless
1245           you are using very large hard disks with large cache (>= 1 MB) that
1246           are able to take advantage of more than 32 tagged commands.
1247
1248           There is no safe option and the default answer is recommended.
1249
1250 config SCSI_NCR53C8XX_SYNC
1251         int "synchronous transfers frequency in MHz"
1252         depends on SCSI_ZALON || SCSI_NCR_Q720
1253         default "20"
1254         ---help---
1255           The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1256           rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80.  The numbers
1257           are respectively the maximum data transfer rates in mega-transfers
1258           per second for each class.  For example, a FAST-20 Wide 16 device is
1259           able to transfer data at 20 million 16 bit packets per second for a
1260           total rate of 40 MB/s.
1261
1262           You may specify 0 if you want to only use asynchronous data
1263           transfers. This is the safest and slowest option. Otherwise, specify
1264           a value between 5 and 80, depending on the capability of your SCSI
1265           controller.  The higher the number, the faster the data transfer.
1266           Note that 80 should normally be ok since the driver decreases the
1267           value automatically according to the controller's capabilities.
1268
1269           Your answer to this question is ignored for controllers with NVRAM,
1270           since the driver will get this information from the user set-up.  It
1271           also can be overridden using a boot setup option, as follows
1272           (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1273           for FAST-20 synchronous data transfer (20 mega-transfers per
1274           second).
1275
1276           The normal answer therefore is not to go with the default but to
1277           select the maximum value 80 allowing the driver to use the maximum
1278           value supported by each controller. If this causes problems with
1279           your SCSI devices, you should come back and decrease the value.
1280
1281           There is no safe option other than using good cabling, right
1282           terminations and SCSI conformant devices.
1283
1284 config SCSI_NCR53C8XX_NO_DISCONNECT
1285         bool "not allow targets to disconnect"
1286         depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1287         help
1288           This option is only provided for safety if you suspect some SCSI
1289           device of yours to not support properly the target-disconnect
1290           feature. In that case, you would say Y here. In general however, to
1291           not allow targets to disconnect is not reasonable if there is more
1292           than 1 device on a SCSI bus. The normal answer therefore is N.
1293
1294 config SCSI_PAS16
1295         tristate "PAS16 SCSI support"
1296         depends on ISA && SCSI
1297         select SCSI_SPI_ATTRS
1298         ---help---
1299           This is support for a SCSI host adapter.  It is explained in section
1300           3.10 of the SCSI-HOWTO, available from
1301           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1302           of the box, you may have to change some settings in
1303           <file:drivers/scsi/pas16.h>.
1304
1305           To compile this driver as a module, choose M here: the
1306           module will be called pas16.
1307
1308 config SCSI_QLOGIC_FAS
1309         tristate "Qlogic FAS SCSI support"
1310         depends on ISA && SCSI
1311         ---help---
1312           This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1313           FastSCSI! cards as well as any other card based on the FASXX chip
1314           (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1315
1316           This driver does NOT support the PCI versions of these cards. The
1317           PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1318           SCSI support"), below.
1319
1320           Information about this driver is contained in
1321           <file:Documentation/scsi/qlogicfas.txt>.  You should also read the
1322           SCSI-HOWTO, available from
1323           <http://www.tldp.org/docs.html#howto>.
1324
1325           To compile this driver as a module, choose M here: the
1326           module will be called qlogicfas.
1327
1328 config SCSI_QLOGIC_1280
1329         tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
1330         depends on PCI && SCSI
1331         help
1332           Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
1333
1334           To compile this driver as a module, choose M here: the
1335           module will be called qla1280.
1336
1337 config SCSI_QLOGICPTI
1338         tristate "PTI Qlogic, ISP Driver"
1339         depends on SBUS && SCSI
1340         help
1341           This driver supports SBUS SCSI controllers from PTI or QLogic. These
1342           controllers are known under Solaris as qpti and in the openprom as
1343           PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1344           driven by a different driver.
1345
1346           To compile this driver as a module, choose M here: the
1347           module will be called qlogicpti.
1348
1349 source "drivers/scsi/qla2xxx/Kconfig"
1350 source "drivers/scsi/qla4xxx/Kconfig"
1351
1352 config SCSI_LPFC
1353         tristate "Emulex LightPulse Fibre Channel Support"
1354         depends on PCI && SCSI
1355         select SCSI_FC_ATTRS
1356         help
1357           This lpfc driver supports the Emulex LightPulse
1358           Family of Fibre Channel PCI host adapters.
1359
1360 config SCSI_LPFC_DEBUG_FS
1361         bool "Emulex LightPulse Fibre Channel debugfs Support"
1362         depends on SCSI_LPFC && DEBUG_FS
1363         help
1364           This makes debugging information from the lpfc driver
1365           available via the debugfs filesystem.
1366
1367 config SCSI_SIM710
1368         tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1369         depends on (EISA || MCA) && SCSI
1370         select SCSI_SPI_ATTRS
1371         ---help---
1372           This driver is for NCR53c710 based SCSI host adapters.
1373
1374           It currently supports Compaq EISA cards and NCR MCA cards
1375
1376 config SCSI_SYM53C416
1377         tristate "Symbios 53c416 SCSI support"
1378         depends on ISA && SCSI
1379         ---help---
1380           This is support for the sym53c416 SCSI host adapter, the SCSI
1381           adapter that comes with some HP scanners. This driver requires that
1382           the sym53c416 is configured first using some sort of PnP
1383           configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1384           are using isapnp then you need to compile this driver as a module
1385           and then load it using insmod after isapnp has run. The parameters
1386           of the configured card(s) should be passed to the driver. The format
1387           is:
1388
1389           insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1390
1391           To compile this driver as a module, choose M here: the
1392           module will be called sym53c416.
1393
1394 config SCSI_DC395x
1395         tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
1396         depends on PCI && SCSI && EXPERIMENTAL
1397         ---help---
1398           This driver supports PCI SCSI host adapters based on the ASIC
1399           TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1400
1401           This driver works, but is still in experimental status. So better
1402           have a bootable disk and a backup in case of emergency.
1403
1404           Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1405
1406           To compile this driver as a module, choose M here: the
1407           module will be called dc395x.
1408
1409 config SCSI_DC390T
1410         tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
1411         depends on PCI && SCSI
1412         ---help---
1413           This driver supports PCI SCSI host adapters based on the Am53C974A
1414           chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1415           PCscsi/PCnet (Am53/79C974) solutions.
1416
1417           Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1418
1419           Note that this driver does NOT support Tekram DC390W/U/F, which are
1420           based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1421
1422           To compile this driver as a module, choose M here: the
1423           module will be called tmscsim.
1424
1425 config SCSI_T128
1426         tristate "Trantor T128/T128F/T228 SCSI support"
1427         depends on ISA && SCSI
1428         select SCSI_SPI_ATTRS
1429         select CHECK_SIGNATURE
1430         ---help---
1431           This is support for a SCSI host adapter. It is explained in section
1432           3.11 of the SCSI-HOWTO, available from
1433           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1434           of the box, you may have to change some settings in
1435           <file:drivers/scsi/t128.h>.  Note that Trantor was purchased by
1436           Adaptec, and some former Trantor products are being sold under the
1437           Adaptec name.
1438
1439           To compile this driver as a module, choose M here: the
1440           module will be called t128.
1441
1442 config SCSI_U14_34F
1443         tristate "UltraStor 14F/34F support"
1444         depends on ISA && SCSI && ISA_DMA_API
1445         ---help---
1446           This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1447           The source at <file:drivers/scsi/u14-34f.c> contains some
1448           information about this hardware.  If the driver doesn't work out of
1449           the box, you may have to change some settings in
1450           <file: drivers/scsi/u14-34f.c>.  Read the SCSI-HOWTO, available from
1451           <http://www.tldp.org/docs.html#howto>.  Note that there is also
1452           another driver for the same hardware: "UltraStor SCSI support",
1453           below.  You should say Y to both only if you want 24F support as
1454           well.
1455
1456           To compile this driver as a module, choose M here: the
1457           module will be called u14-34f.
1458
1459 config SCSI_U14_34F_TAGGED_QUEUE
1460         bool "enable tagged command queueing"
1461         depends on SCSI_U14_34F
1462         help
1463           This is a feature of SCSI-2 which improves performance: the host
1464           adapter can send several SCSI commands to a device's queue even if
1465           previous commands haven't finished yet.
1466           This is equivalent to the "u14-34f=tc:y" boot option.
1467
1468 config SCSI_U14_34F_LINKED_COMMANDS
1469         bool "enable elevator sorting"
1470         depends on SCSI_U14_34F
1471         help
1472           This option enables elevator sorting for all probed SCSI disks and
1473           CD-ROMs. It definitely reduces the average seek distance when doing
1474           random seeks, but this does not necessarily result in a noticeable
1475           performance improvement: your mileage may vary...
1476           This is equivalent to the "u14-34f=lc:y" boot option.
1477
1478 config SCSI_U14_34F_MAX_TAGS
1479         int "maximum number of queued commands"
1480         depends on SCSI_U14_34F
1481         default "8"
1482         help
1483           This specifies how many SCSI commands can be maximally queued for
1484           each probed SCSI device. You should reduce the default value of 8
1485           only if you have disks with buggy or limited tagged command support.
1486           Minimum is 2 and maximum is 14. This value is also the window size
1487           used by the elevator sorting option above. The effective value used
1488           by the driver for each probed SCSI device is reported at boot time.
1489           This is equivalent to the "u14-34f=mq:8" boot option.
1490
1491 config SCSI_ULTRASTOR
1492         tristate "UltraStor SCSI support"
1493         depends on X86 && ISA && SCSI
1494         ---help---
1495           This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1496           adapter family.  This driver is explained in section 3.12 of the
1497           SCSI-HOWTO, available from
1498           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1499           of the box, you may have to change some settings in
1500           <file:drivers/scsi/ultrastor.h>.
1501
1502           Note that there is also another driver for the same hardware:
1503           "UltraStor 14F/34F support", above.
1504
1505           To compile this driver as a module, choose M here: the
1506           module will be called ultrastor.
1507
1508 config SCSI_NSP32
1509         tristate "Workbit NinjaSCSI-32Bi/UDE support"
1510         depends on PCI && SCSI && !64BIT
1511         help
1512           This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1513           SCSI host adapter. Please read the SCSI-HOWTO, available from
1514           <http://www.tldp.org/docs.html#howto>.
1515
1516           To compile this driver as a module, choose M here: the
1517           module will be called nsp32.
1518
1519 config SCSI_DEBUG
1520         tristate "SCSI debugging host simulator"
1521         depends on SCSI
1522         select CRC_T10DIF
1523         help
1524           This is a host adapter simulator that can simulate multiple hosts
1525           each with multiple dummy SCSI devices (disks). It defaults to one
1526           host adapter with one dummy SCSI disk. Each dummy disk uses kernel
1527           RAM as storage (i.e. it is a ramdisk). To save space when multiple
1528           dummy disks are simulated, they share the same kernel RAM for 
1529           their storage. See <http://sg.danny.cz/sg/sdebug26.html> for more
1530           information. This driver is primarily of use to those testing the
1531           SCSI and block subsystems. If unsure, say N.
1532
1533 config SCSI_MESH
1534         tristate "MESH (Power Mac internal SCSI) support"
1535         depends on PPC32 && PPC_PMAC && SCSI
1536         help
1537           Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1538           SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1539           other Power Macintoshes do). Say Y to include support for this SCSI
1540           adaptor.
1541
1542           To compile this driver as a module, choose M here: the
1543           module will be called mesh.
1544
1545 config SCSI_MESH_SYNC_RATE
1546         int "maximum synchronous transfer rate (MB/s) (0 = async)"
1547         depends on SCSI_MESH
1548         default "5"
1549         help
1550           On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1551           drives a bus which is entirely internal to the machine (such as the
1552           7500, 7600, 8500, etc.), the MESH is capable of synchronous
1553           operation at up to 10 MB/s. On machines where the SCSI bus
1554           controlled by the MESH can have external devices connected, it is
1555           usually rated at 5 MB/s. 5 is a safe value here unless you know the
1556           MESH SCSI bus is internal only; in that case you can say 10. Say 0
1557           to disable synchronous operation.
1558
1559 config SCSI_MESH_RESET_DELAY_MS
1560         int "initial bus reset delay (ms) (0 = no reset)"
1561         depends on SCSI_MESH
1562         default "4000"
1563
1564 config SCSI_MAC53C94
1565         tristate "53C94 (Power Mac external SCSI) support"
1566         depends on PPC32 && PPC_PMAC && SCSI
1567         help
1568           On Power Macintoshes (and clones) with two SCSI buses, the external
1569           SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1570           machines which only have one SCSI bus, such as the 7200, also use
1571           the 53C94. Say Y to include support for the 53C94.
1572
1573           To compile this driver as a module, choose M here: the
1574           module will be called mac53c94.
1575
1576 source "drivers/scsi/arm/Kconfig"
1577
1578 config JAZZ_ESP
1579         bool "MIPS JAZZ FAS216 SCSI support"
1580         depends on MACH_JAZZ && SCSI
1581         select SCSI_SPI_ATTRS
1582         help
1583           This is the driver for the onboard SCSI host adapter of MIPS Magnum
1584           4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1585           systems.
1586
1587 config A3000_SCSI
1588         tristate "A3000 WD33C93A support"
1589         depends on AMIGA && SCSI
1590         help
1591           If you have an Amiga 3000 and have SCSI devices connected to the
1592           built-in SCSI controller, say Y. Otherwise, say N.
1593
1594           To compile this driver as a module, choose M here: the
1595           module will be called a3000.
1596
1597 config A2091_SCSI
1598         tristate "A2091/A590 WD33C93A support"
1599         depends on ZORRO && SCSI
1600         help
1601           If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1602           say N.
1603
1604           To compile this driver as a module, choose M here: the
1605           module will be called a2091.
1606
1607 config GVP11_SCSI
1608         tristate "GVP Series II WD33C93A support"
1609         depends on ZORRO && SCSI
1610         ---help---
1611           If you have a Great Valley Products Series II SCSI controller,
1612           answer Y. Also say Y if you have a later model of GVP SCSI
1613           controller (such as the GVP A4008 or a Combo board). Otherwise,
1614           answer N. This driver does NOT work for the T-Rex series of
1615           accelerators from TekMagic and GVP-M.
1616
1617           To compile this driver as a module, choose M here: the
1618           module will be called gvp11.
1619
1620 config SCSI_A4000T
1621         tristate "A4000T NCR53c710 SCSI support (EXPERIMENTAL)"
1622         depends on AMIGA && SCSI && EXPERIMENTAL
1623         select SCSI_SPI_ATTRS
1624         help
1625           If you have an Amiga 4000T and have SCSI devices connected to the
1626           built-in SCSI controller, say Y. Otherwise, say N.
1627
1628           To compile this driver as a module, choose M here: the
1629           module will be called a4000t.
1630
1631 config SCSI_ZORRO7XX
1632         tristate "Zorro NCR53c710 SCSI support (EXPERIMENTAL)"
1633         depends on ZORRO && SCSI && EXPERIMENTAL
1634         select SCSI_SPI_ATTRS
1635         help
1636           Support for various NCR53c710-based SCSI controllers on Zorro
1637           expansion boards for the Amiga.
1638           This includes:
1639             - the Amiga 4091 Zorro III SCSI-2 controller,
1640             - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1641               (info at
1642               <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1643             - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1644               accelerator card for the Amiga 1200,
1645             - the SCSI controller on the GVP Turbo 040/060 accelerator.
1646
1647 config ATARI_SCSI
1648         tristate "Atari native SCSI support"
1649         depends on ATARI && SCSI
1650         select SCSI_SPI_ATTRS
1651         select NVRAM
1652         ---help---
1653           If you have an Atari with built-in NCR5380 SCSI controller (TT,
1654           Falcon, ...) say Y to get it supported. Of course also, if you have
1655           a compatible SCSI controller (e.g. for Medusa).
1656
1657           To compile this driver as a module, choose M here: the
1658           module will be called atari_scsi.
1659
1660           This driver supports both styles of NCR integration into the
1661           system: the TT style (separate DMA), and the Falcon style (via
1662           ST-DMA, replacing ACSI).  It does NOT support other schemes, like
1663           in the Hades (without DMA).
1664
1665 config ATARI_SCSI_TOSHIBA_DELAY
1666         bool "Long delays for Toshiba CD-ROMs"
1667         depends on ATARI_SCSI
1668         help
1669           This option increases the delay after a SCSI arbitration to
1670           accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1671           use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1672           would impact performance a bit, so say N.
1673
1674 config ATARI_SCSI_RESET_BOOT
1675         bool "Reset SCSI-devices at boottime"
1676         depends on ATARI_SCSI
1677         help
1678           Reset the devices on your Atari whenever it boots.  This makes the
1679           boot process fractionally longer but may assist recovery from errors
1680           that leave the devices with SCSI operations partway completed.
1681
1682 config MAC_SCSI
1683         bool "Macintosh NCR5380 SCSI"
1684         depends on MAC && SCSI=y
1685         select SCSI_SPI_ATTRS
1686         help
1687           This is the NCR 5380 SCSI controller included on most of the 68030
1688           based Macintoshes.  If you have one of these say Y and read the
1689           SCSI-HOWTO, available from
1690           <http://www.tldp.org/docs.html#howto>.
1691
1692 config SCSI_MAC_ESP
1693         tristate "Macintosh NCR53c9[46] SCSI"
1694         depends on MAC && SCSI
1695         select SCSI_SPI_ATTRS
1696         help
1697           This is the NCR 53c9x SCSI controller found on most of the 68040
1698           based Macintoshes.
1699
1700           To compile this driver as a module, choose M here: the module
1701           will be called mac_esp.
1702
1703 config MVME147_SCSI
1704         bool "WD33C93 SCSI driver for MVME147"
1705         depends on MVME147 && SCSI=y
1706         select SCSI_SPI_ATTRS
1707         help
1708           Support for the on-board SCSI controller on the Motorola MVME147
1709           single-board computer.
1710
1711 config MVME16x_SCSI
1712         tristate "NCR53C710 SCSI driver for MVME16x"
1713         depends on MVME16x && SCSI
1714         select SCSI_SPI_ATTRS
1715         help
1716           The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1717           SCSI controller chip.  Almost everyone using one of these boards
1718           will want to say Y to this question.
1719
1720 config BVME6000_SCSI
1721         tristate "NCR53C710 SCSI driver for BVME6000"
1722         depends on BVME6000 && SCSI
1723         select SCSI_SPI_ATTRS
1724         help
1725           The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1726           SCSI controller chip.  Almost everyone using one of these boards
1727           will want to say Y to this question.
1728
1729 config SUN3_SCSI
1730         tristate "Sun3 NCR5380 SCSI"
1731         depends on SUN3 && SCSI
1732         select SCSI_SPI_ATTRS
1733         help
1734           This option will enable support for the OBIO (onboard io) NCR5380
1735           SCSI controller found in the Sun 3/50 and 3/60, as well as for
1736           "Sun3" type VME scsi controllers also based on the NCR5380.
1737           General Linux information on the Sun 3 series (now discontinued)
1738           is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1739
1740 config SUN3X_ESP
1741         bool "Sun3x ESP SCSI"
1742         depends on SUN3X && SCSI=y
1743         select SCSI_SPI_ATTRS
1744         help
1745           The ESP was an on-board SCSI controller used on Sun 3/80
1746           machines.  Say Y here to compile in support for it.
1747
1748 config SCSI_SUNESP
1749         tristate "Sparc ESP Scsi Driver"
1750         depends on SBUS && SCSI
1751         select SCSI_SPI_ATTRS
1752         help
1753           This is the driver for the Sun ESP SCSI host adapter. The ESP
1754           chipset is present in most SPARC SBUS-based computers and
1755           supports the Emulex family of ESP SCSI chips (esp100, esp100A,
1756           esp236, fas101, fas236) as well as the Qlogic fas366 SCSI chip.
1757
1758           To compile this driver as a module, choose M here: the
1759           module will be called sun_esp.
1760
1761 config ZFCP
1762         tristate "FCP host bus adapter driver for IBM eServer zSeries"
1763         depends on S390 && QDIO && SCSI
1764         select SCSI_FC_ATTRS
1765         help
1766           If you want to access SCSI devices attached to your IBM eServer
1767           zSeries by means of Fibre Channel interfaces say Y.
1768           For details please refer to the documentation provided by IBM at
1769           <http://oss.software.ibm.com/developerworks/opensource/linux390>
1770
1771           This driver is also available as a module. This module will be
1772           called zfcp. If you want to compile it as a module, say M here
1773           and read <file:Documentation/kbuild/modules.txt>.
1774
1775 config SCSI_PMCRAID
1776         tristate "PMC SIERRA Linux MaxRAID adapter support"
1777         depends on PCI && SCSI && NET
1778         ---help---
1779           This driver supports the PMC SIERRA MaxRAID adapters.
1780
1781 config SCSI_PM8001
1782         tristate "PMC-Sierra SPC 8001 SAS/SATA Based Host Adapter driver"
1783         depends on PCI && SCSI
1784         select SCSI_SAS_LIBSAS
1785         help
1786           This driver supports PMC-Sierra PCIE SAS/SATA 8x6G SPC 8001 chip
1787           based host adapters.
1788
1789 config SCSI_SRP
1790         tristate "SCSI RDMA Protocol helper library"
1791         depends on SCSI && PCI
1792         select SCSI_TGT
1793         help
1794           If you wish to use SRP target drivers, say Y.
1795
1796           To compile this driver as a module, choose M here: the
1797           module will be called libsrp.
1798
1799 config SCSI_BFA_FC
1800         tristate "Brocade BFA Fibre Channel Support"
1801         depends on PCI && SCSI
1802         select SCSI_FC_ATTRS
1803         help
1804           This bfa driver supports all Brocade PCIe FC/FCOE host adapters.
1805
1806           To compile this driver as a module, choose M here. The module will
1807           be called bfa.
1808
1809 config SCSI_VIRTIO
1810         tristate "virtio-scsi support (EXPERIMENTAL)"
1811         depends on EXPERIMENTAL && VIRTIO
1812         help
1813           This is the virtual HBA driver for virtio.  If the kernel will
1814           be used in a virtual machine, say Y or M.
1815
1816 source "drivers/scsi/csiostor/Kconfig"
1817
1818 endif # SCSI_LOWLEVEL
1819
1820 source "drivers/scsi/pcmcia/Kconfig"
1821
1822 source "drivers/scsi/device_handler/Kconfig"
1823
1824 source "drivers/scsi/osd/Kconfig"
1825
1826 endmenu