Merge branch 'slab/urgent' of git://git.kernel.org/pub/scm/linux/kernel/git/penberg...
[platform/adaptation/renesas_rcar/renesas_kernel.git] / drivers / scsi / Kconfig
1 menu "SCSI device support"
2
3 config SCSI_MOD
4        tristate
5        default y if SCSI=n || SCSI=y
6        default m if SCSI=m
7
8 config RAID_ATTRS
9         tristate "RAID Transport Class"
10         default n
11         depends on BLOCK
12         depends on SCSI_MOD
13         ---help---
14           Provides RAID
15
16 config SCSI
17         tristate "SCSI device support"
18         depends on BLOCK
19         select SCSI_DMA if HAS_DMA
20         ---help---
21           If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
22           any other SCSI device under Linux, say Y and make sure that you know
23           the name of your SCSI host adapter (the card inside your computer
24           that "speaks" the SCSI protocol, also called SCSI controller),
25           because you will be asked for it.
26
27           You also need to say Y here if you have a device which speaks
28           the SCSI protocol.  Examples of this include the parallel port
29           version of the IOMEGA ZIP drive, USB storage devices, Fibre
30           Channel, and FireWire storage.
31
32           To compile this driver as a module, choose M here and read
33           <file:Documentation/scsi/scsi.txt>.
34           The module will be called scsi_mod.
35
36           However, do not compile this as a module if your root file system
37           (the one containing the directory /) is located on a SCSI device.
38
39 config SCSI_DMA
40         bool
41         default n
42
43 config SCSI_TGT
44         tristate "SCSI target support"
45         depends on SCSI
46         ---help---
47           If you want to use SCSI target mode drivers enable this option.
48           If you choose M, the module will be called scsi_tgt.
49
50 config SCSI_NETLINK
51         bool
52         default n
53         select NET
54
55 config SCSI_PROC_FS
56         bool "legacy /proc/scsi/ support"
57         depends on SCSI && PROC_FS
58         default y
59         ---help---
60           This option enables support for the various files in
61           /proc/scsi.  In Linux 2.6 this has been superseded by
62           files in sysfs but many legacy applications rely on this.
63
64           If unsure say Y.
65
66 comment "SCSI support type (disk, tape, CD-ROM)"
67         depends on SCSI
68
69 config BLK_DEV_SD
70         tristate "SCSI disk support"
71         depends on SCSI
72         select CRC_T10DIF if BLK_DEV_INTEGRITY
73         ---help---
74           If you want to use SCSI hard disks, Fibre Channel disks,
75           Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
76           USB storage or the SCSI or parallel port version of
77           the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
78           the Disk-HOWTO and the Multi-Disk-HOWTO, available from
79           <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
80           CD-ROMs.
81
82           To compile this driver as a module, choose M here and read
83           <file:Documentation/scsi/scsi.txt>.
84           The module will be called sd_mod.
85
86           Do not compile this driver as a module if your root file system
87           (the one containing the directory /) is located on a SCSI disk.
88           In this case, do not compile the driver for your SCSI host adapter
89           (below) as a module either.
90
91 config CHR_DEV_ST
92         tristate "SCSI tape support"
93         depends on SCSI
94         ---help---
95           If you want to use a SCSI tape drive under Linux, say Y and read the
96           SCSI-HOWTO, available from
97           <http://www.tldp.org/docs.html#howto>, and
98           <file:Documentation/scsi/st.txt> in the kernel source.  This is NOT
99           for SCSI CD-ROMs.
100
101           To compile this driver as a module, choose M here and read
102           <file:Documentation/scsi/scsi.txt>. The module will be called st.
103
104 config CHR_DEV_OSST
105         tristate "SCSI OnStream SC-x0 tape support"
106         depends on SCSI
107         ---help---
108           The OnStream SC-x0 SCSI tape drives cannot be driven by the
109           standard st driver, but instead need this special osst driver and
110           use the  /dev/osstX char device nodes (major 206).  Via usb-storage,
111           you may be able to drive the USB-x0 and DI-x0 drives as well.
112           Note that there is also a second generation of OnStream
113           tape drives (ADR-x0) that supports the standard SCSI-2 commands for
114           tapes (QIC-157) and can be driven by the standard driver st.
115           For more information, you may have a look at the SCSI-HOWTO
116           <http://www.tldp.org/docs.html#howto>  and
117           <file:Documentation/scsi/osst.txt>  in the kernel source.
118           More info on the OnStream driver may be found on
119           <http://sourceforge.net/projects/osst/>
120           Please also have a look at the standard st docu, as most of it
121           applies to osst as well.
122
123           To compile this driver as a module, choose M here and read
124           <file:Documentation/scsi/scsi.txt>. The module will be called osst.
125
126 config BLK_DEV_SR
127         tristate "SCSI CDROM support"
128         depends on SCSI
129         ---help---
130           If you want to use a CD or DVD drive attached to your computer
131           by SCSI, FireWire, USB or ATAPI, say Y and read the SCSI-HOWTO
132           and the CDROM-HOWTO at <http://www.tldp.org/docs.html#howto>.
133
134           Make sure to say Y or M to "ISO 9660 CD-ROM file system support".
135
136           To compile this driver as a module, choose M here and read
137           <file:Documentation/scsi/scsi.txt>.
138           The module will be called sr_mod.
139
140 config BLK_DEV_SR_VENDOR
141         bool "Enable vendor-specific extensions (for SCSI CDROM)"
142         depends on BLK_DEV_SR
143         help
144           This enables the usage of vendor specific SCSI commands. This is
145           required to support multisession CDs with old NEC/TOSHIBA cdrom
146           drives (and HP Writers). If you have such a drive and get the first
147           session only, try saying Y here; everybody else says N.
148
149 config CHR_DEV_SG
150         tristate "SCSI generic support"
151         depends on SCSI
152         ---help---
153           If you want to use SCSI scanners, synthesizers or CD-writers or just
154           about anything having "SCSI" in its name other than hard disks,
155           CD-ROMs or tapes, say Y here. These won't be supported by the kernel
156           directly, so you need some additional software which knows how to
157           talk to these devices using the SCSI protocol:
158
159           For scanners, look at SANE (<http://www.sane-project.org/>). For CD
160           writer software look at Cdrtools
161           (<http://cdrecord.berlios.de/private/cdrecord.html>)
162           and for burning a "disk at once": CDRDAO
163           (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
164           quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
165           For other devices, it's possible that you'll have to write the
166           driver software yourself. Please read the file
167           <file:Documentation/scsi/scsi-generic.txt> for more information.
168
169           To compile this driver as a module, choose M here and read
170           <file:Documentation/scsi/scsi.txt>. The module will be called sg.
171
172           If unsure, say N.
173
174 config CHR_DEV_SCH
175         tristate "SCSI media changer support"
176         depends on SCSI
177         ---help---
178           This is a driver for SCSI media changers.  Most common devices are
179           tape libraries and MOD/CDROM jukeboxes.  *Real* jukeboxes, you
180           don't need this for those tiny 6-slot cdrom changers.  Media
181           changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
182           If you have such hardware and want to use it with linux, say Y
183           here.  Check <file:Documentation/scsi/scsi-changer.txt> for details.
184         
185           If you want to compile this as a module ( = code which can be
186           inserted in and removed from the running kernel whenever you want),
187           say M here and read <file:Documentation/kbuild/modules.txt> and
188           <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
189           If unsure, say N.
190
191 config SCSI_ENCLOSURE
192         tristate "SCSI Enclosure Support"
193         depends on SCSI && ENCLOSURE_SERVICES
194         help
195           Enclosures are devices sitting on or in SCSI backplanes that
196           manage devices.  If you have a disk cage, the chances are that
197           it has an enclosure device.  Selecting this option will just allow
198           certain enclosure conditions to be reported and is not required.
199
200 config SCSI_MULTI_LUN
201         bool "Probe all LUNs on each SCSI device"
202         depends on SCSI
203         help
204           Some devices support more than one LUN (Logical Unit Number) in order
205           to allow access to several media, e.g. CD jukebox, USB card reader,
206           mobile phone in mass storage mode. This option forces the kernel to
207           probe for all LUNs by default. This setting can be overriden by
208           max_luns boot/module parameter. Note that this option does not affect
209           devices conforming to SCSI-3 or higher as they can explicitely report
210           their number of LUNs. It is safe to say Y here unless you have one of
211           those rare devices which reacts in an unexpected way when probed for
212           multiple LUNs.
213
214 config SCSI_CONSTANTS
215         bool "Verbose SCSI error reporting (kernel size +=12K)"
216         depends on SCSI
217         help
218           The error messages regarding your SCSI hardware will be easier to
219           understand if you say Y here; it will enlarge your kernel by about
220           12 KB. If in doubt, say Y.
221
222 config SCSI_LOGGING
223         bool "SCSI logging facility"
224         depends on SCSI
225         ---help---
226           This turns on a logging facility that can be used to debug a number
227           of SCSI related problems.
228
229           If you say Y here, no logging output will appear by default, but you
230           can enable logging by saying Y to "/proc file system support" and
231           "Sysctl support" below and executing the command
232
233           echo <bitmask> > /proc/sys/dev/scsi/logging_level
234
235           where <bitmask> is a four byte value representing the logging type
236           and logging level for each type of logging selected.
237
238           There are a number of logging types and you can find them in the
239           source at <file:drivers/scsi/scsi_logging.h>. The logging levels
240           are also described in that file and they determine the verbosity of
241           the logging for each logging type.
242
243           If you say N here, it may be harder to track down some types of SCSI
244           problems. If you say Y here your kernel will be somewhat larger, but
245           there should be no noticeable performance impact as long as you have
246           logging turned off.
247
248 config SCSI_SCAN_ASYNC
249         bool "Asynchronous SCSI scanning"
250         depends on SCSI
251         help
252           The SCSI subsystem can probe for devices while the rest of the
253           system continues booting, and even probe devices on different
254           busses in parallel, leading to a significant speed-up.
255
256           If you have built SCSI as modules, enabling this option can
257           be a problem as the devices may not have been found by the
258           time your system expects them to have been.  You can load the
259           scsi_wait_scan module to ensure that all scans have completed.
260           If you build your SCSI drivers into the kernel, then everything
261           will work fine if you say Y here.
262
263           You can override this choice by specifying "scsi_mod.scan=sync"
264           or async on the kernel's command line.
265
266 menu "SCSI Transports"
267         depends on SCSI
268
269 config SCSI_SPI_ATTRS
270         tristate "Parallel SCSI (SPI) Transport Attributes"
271         depends on SCSI
272         help
273           If you wish to export transport-specific information about
274           each attached SCSI device to sysfs, say Y.  Otherwise, say N.
275
276 config SCSI_FC_ATTRS
277         tristate "FiberChannel Transport Attributes"
278         depends on SCSI
279         select SCSI_NETLINK
280         help
281           If you wish to export transport-specific information about
282           each attached FiberChannel device to sysfs, say Y.
283           Otherwise, say N.
284
285 config SCSI_FC_TGT_ATTRS
286         bool "SCSI target support for FiberChannel Transport Attributes"
287         depends on SCSI_FC_ATTRS
288         depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
289         help
290                 If you want to use SCSI target mode drivers enable this option.
291
292 config SCSI_ISCSI_ATTRS
293         tristate "iSCSI Transport Attributes"
294         depends on SCSI && NET
295         select BLK_DEV_BSGLIB
296         help
297           If you wish to export transport-specific information about
298           each attached iSCSI device to sysfs, say Y.
299           Otherwise, say N.
300
301 config SCSI_SAS_ATTRS
302         tristate "SAS Transport Attributes"
303         depends on SCSI
304         select BLK_DEV_BSG
305         help
306           If you wish to export transport-specific information about
307           each attached SAS device to sysfs, say Y.
308
309 source "drivers/scsi/libsas/Kconfig"
310
311 config SCSI_SRP_ATTRS
312         tristate "SRP Transport Attributes"
313         depends on SCSI
314         help
315           If you wish to export transport-specific information about
316           each attached SRP device to sysfs, say Y.
317
318 config SCSI_SRP_TGT_ATTRS
319         bool "SCSI target support for SRP Transport Attributes"
320         depends on SCSI_SRP_ATTRS
321         depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
322         help
323                 If you want to use SCSI target mode drivers enable this option.
324
325 endmenu
326
327 menuconfig SCSI_LOWLEVEL
328         bool "SCSI low-level drivers"
329         depends on SCSI!=n
330         default y
331
332 if SCSI_LOWLEVEL && SCSI
333
334 config ISCSI_TCP
335         tristate "iSCSI Initiator over TCP/IP"
336         depends on SCSI && INET
337         select CRYPTO
338         select CRYPTO_MD5
339         select CRYPTO_CRC32C
340         select SCSI_ISCSI_ATTRS
341         help
342          The iSCSI Driver provides a host with the ability to access storage
343          through an IP network. The driver uses the iSCSI protocol to transport
344          SCSI requests and responses over a TCP/IP network between the host
345          (the "initiator") and "targets".  Architecturally, the iSCSI driver
346          combines with the host's TCP/IP stack, network drivers, and Network
347          Interface Card (NIC) to provide the same functions as a SCSI or a
348          Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
349
350          To compile this driver as a module, choose M here: the
351          module will be called iscsi_tcp.
352
353          The userspace component needed to initialize the driver, documentation,
354          and sample configuration files can be found here:
355
356          http://open-iscsi.org
357
358 config ISCSI_BOOT_SYSFS
359         tristate "iSCSI Boot Sysfs Interface"
360         default n
361         help
362           This option enables support for exposing iSCSI boot information
363           via sysfs to userspace. If you wish to export this information,
364           say Y. Otherwise, say N.
365
366 source "drivers/scsi/cxgbi/Kconfig"
367 source "drivers/scsi/bnx2i/Kconfig"
368 source "drivers/scsi/bnx2fc/Kconfig"
369 source "drivers/scsi/be2iscsi/Kconfig"
370
371 config SGIWD93_SCSI
372         tristate "SGI WD93C93 SCSI Driver"
373         depends on SGI_HAS_WD93 && SCSI
374         help
375           If you have a Western Digital WD93 SCSI controller on
376           an SGI MIPS system, say Y.  Otherwise, say N.
377
378 config BLK_DEV_3W_XXXX_RAID
379         tristate "3ware 5/6/7/8xxx ATA-RAID support"
380         depends on PCI && SCSI
381         help
382           3ware is the only hardware ATA-Raid product in Linux to date.
383           This card is 2,4, or 8 channel master mode support only.
384           SCSI support required!!!
385
386           <http://www.3ware.com/>
387
388           Please read the comments at the top of
389           <file:drivers/scsi/3w-xxxx.c>.
390
391 config SCSI_HPSA
392         tristate "HP Smart Array SCSI driver"
393         depends on PCI && SCSI
394         select CHECK_SIGNATURE
395         help
396           This driver supports HP Smart Array Controllers (circa 2009).
397           It is a SCSI alternative to the cciss driver, which is a block
398           driver.  Anyone wishing to use HP Smart Array controllers who
399           would prefer the devices be presented to linux as SCSI devices,
400           rather than as generic block devices should say Y here.
401
402 config SCSI_3W_9XXX
403         tristate "3ware 9xxx SATA-RAID support"
404         depends on PCI && SCSI
405         help
406           This driver supports the 9000 series 3ware SATA-RAID cards.
407
408           <http://www.amcc.com>
409
410           Please read the comments at the top of
411           <file:drivers/scsi/3w-9xxx.c>.
412
413 config SCSI_3W_SAS
414         tristate "3ware 97xx SAS/SATA-RAID support"
415         depends on PCI && SCSI
416         help
417           This driver supports the LSI 3ware 9750 6Gb/s SAS/SATA-RAID cards.
418
419           <http://www.lsi.com>
420
421           Please read the comments at the top of
422           <file:drivers/scsi/3w-sas.c>.
423
424 config SCSI_7000FASST
425         tristate "7000FASST SCSI support"
426         depends on ISA && SCSI && ISA_DMA_API
427         select CHECK_SIGNATURE
428         help
429           This driver supports the Western Digital 7000 SCSI host adapter
430           family.  Some information is in the source:
431           <file:drivers/scsi/wd7000.c>.
432
433           To compile this driver as a module, choose M here: the
434           module will be called wd7000.
435
436 config SCSI_ACARD
437         tristate "ACARD SCSI support"
438         depends on PCI && SCSI
439         help
440           This driver supports the ACARD SCSI host adapter.
441           Support Chip <ATP870 ATP876 ATP880 ATP885>
442           To compile this driver as a module, choose M here: the
443           module will be called atp870u.
444
445 config SCSI_AHA152X
446         tristate "Adaptec AHA152X/2825 support"
447         depends on ISA && SCSI
448         select SCSI_SPI_ATTRS
449         select CHECK_SIGNATURE
450         ---help---
451           This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
452           SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
453           must be manually specified in this case.
454
455           It is explained in section 3.3 of the SCSI-HOWTO, available from
456           <http://www.tldp.org/docs.html#howto>. You might also want to
457           read the file <file:Documentation/scsi/aha152x.txt>.
458
459           To compile this driver as a module, choose M here: the
460           module will be called aha152x.
461
462 config SCSI_AHA1542
463         tristate "Adaptec AHA1542 support"
464         depends on ISA && SCSI && ISA_DMA_API
465         ---help---
466           This is support for a SCSI host adapter.  It is explained in section
467           3.4 of the SCSI-HOWTO, available from
468           <http://www.tldp.org/docs.html#howto>.  Note that Trantor was
469           purchased by Adaptec, and some former Trantor products are being
470           sold under the Adaptec name.  If it doesn't work out of the box, you
471           may have to change some settings in <file:drivers/scsi/aha1542.h>.
472
473           To compile this driver as a module, choose M here: the
474           module will be called aha1542.
475
476 config SCSI_AHA1740
477         tristate "Adaptec AHA1740 support"
478         depends on EISA && SCSI
479         ---help---
480           This is support for a SCSI host adapter.  It is explained in section
481           3.5 of the SCSI-HOWTO, available from
482           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
483           of the box, you may have to change some settings in
484           <file:drivers/scsi/aha1740.h>.
485
486           To compile this driver as a module, choose M here: the
487           module will be called aha1740.
488
489 config SCSI_AACRAID
490         tristate "Adaptec AACRAID support"
491         depends on SCSI && PCI
492         help
493           This driver supports a variety of Dell, HP, Adaptec, IBM and
494           ICP storage products. For a list of supported products, refer
495           to <file:Documentation/scsi/aacraid.txt>.
496
497           To compile this driver as a module, choose M here: the module
498           will be called aacraid.
499
500
501 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
502
503 config SCSI_AIC7XXX_OLD
504         tristate "Adaptec AIC7xxx support (old driver)"
505         depends on (ISA || EISA || PCI ) && SCSI
506         help
507           WARNING This driver is an older aic7xxx driver and is no longer
508           under active development.  Adaptec, Inc. is writing a new driver to
509           take the place of this one, and it is recommended that whenever
510           possible, people should use the new Adaptec written driver instead
511           of this one.  This driver will eventually be phased out entirely.
512
513           This is support for the various aic7xxx based Adaptec SCSI
514           controllers. These include the 274x EISA cards; 284x VLB cards;
515           2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
516           motherboard based SCSI controllers from Adaptec. It does not support
517           the AAA-13x RAID controllers from Adaptec, nor will it likely ever
518           support them. It does not support the 2920 cards from Adaptec that
519           use the Future Domain SCSI controller chip. For those cards, you
520           need the "Future Domain 16xx SCSI support" driver.
521
522           In general, if the controller is based on an Adaptec SCSI controller
523           chip from the aic777x series or the aic78xx series, this driver
524           should work. The only exception is the 7810 which is specifically
525           not supported (that's the RAID controller chip on the AAA-13x
526           cards).
527
528           Note that the AHA2920 SCSI host adapter is *not* supported by this
529           driver; choose "Future Domain 16xx SCSI support" instead if you have
530           one of those.
531
532           Information on the configuration options for this controller can be
533           found by checking the help file for each of the available
534           configuration options. You should read
535           <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
536           contacting the maintainer with any questions.  The SCSI-HOWTO,
537           available from <http://www.tldp.org/docs.html#howto>, can also
538           be of great help.
539
540           To compile this driver as a module, choose M here: the
541           module will be called aic7xxx_old.
542
543 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
544 source "drivers/scsi/aic94xx/Kconfig"
545 source "drivers/scsi/mvsas/Kconfig"
546
547 config SCSI_MVUMI
548         tristate "Marvell UMI driver"
549         depends on SCSI && PCI
550         help
551           Module for Marvell Universal Message Interface(UMI) driver
552
553           To compile this driver as a module, choose M here: the
554           module will be called mvumi.
555
556 config SCSI_DPT_I2O
557         tristate "Adaptec I2O RAID support "
558         depends on SCSI && PCI && VIRT_TO_BUS
559         help
560           This driver supports all of Adaptec's I2O based RAID controllers as 
561           well as the DPT SmartRaid V cards.  This is an Adaptec maintained
562           driver by Deanna Bonds.  See <file:Documentation/scsi/dpti.txt>.
563
564           To compile this driver as a module, choose M here: the
565           module will be called dpt_i2o.
566
567 config SCSI_ADVANSYS
568         tristate "AdvanSys SCSI support"
569         depends on SCSI && VIRT_TO_BUS
570         depends on ISA || EISA || PCI
571         help
572           This is a driver for all SCSI host adapters manufactured by
573           AdvanSys. It is documented in the kernel source in
574           <file:drivers/scsi/advansys.c>.
575
576           To compile this driver as a module, choose M here: the
577           module will be called advansys.
578
579 config SCSI_IN2000
580         tristate "Always IN2000 SCSI support"
581         depends on ISA && SCSI
582         help
583           This is support for an ISA bus SCSI host adapter.  You'll find more
584           information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
585           out of the box, you may have to change the jumpers for IRQ or
586           address selection.
587
588           To compile this driver as a module, choose M here: the
589           module will be called in2000.
590
591 config SCSI_ARCMSR
592         tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
593         depends on PCI && SCSI
594         help
595           This driver supports all of ARECA's SATA/SAS RAID controller cards.
596           This is an ARECA-maintained driver by Erich Chen.
597           If you have any problems, please mail to: <erich@areca.com.tw>.
598           Areca supports Linux RAID config tools.
599           Please link <http://www.areca.com.tw>
600
601           To compile this driver as a module, choose M here: the
602           module will be called arcmsr (modprobe arcmsr).
603
604 source "drivers/scsi/esas2r/Kconfig"
605 source "drivers/scsi/megaraid/Kconfig.megaraid"
606 source "drivers/scsi/mpt2sas/Kconfig"
607 source "drivers/scsi/mpt3sas/Kconfig"
608 source "drivers/scsi/ufs/Kconfig"
609
610 config SCSI_HPTIOP
611         tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
612         depends on SCSI && PCI
613         help
614           This option enables support for HighPoint RocketRAID 3xxx/4xxx
615           controllers.
616
617           To compile this driver as a module, choose M here; the module
618           will be called hptiop. If unsure, say N.
619
620 config SCSI_BUSLOGIC
621         tristate "BusLogic SCSI support"
622         depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
623         ---help---
624           This is support for BusLogic MultiMaster and FlashPoint SCSI Host
625           Adapters. Consult the SCSI-HOWTO, available from
626           <http://www.tldp.org/docs.html#howto>, and the files
627           <file:Documentation/scsi/BusLogic.txt> and
628           <file:Documentation/scsi/FlashPoint.txt> for more information.
629           Note that support for FlashPoint is only available for 32-bit
630           x86 configurations.
631
632           To compile this driver as a module, choose M here: the
633           module will be called BusLogic.
634
635 config SCSI_FLASHPOINT
636         bool "FlashPoint support"
637         depends on SCSI_BUSLOGIC && PCI
638         help
639           This option allows you to add FlashPoint support to the
640           BusLogic SCSI driver. The FlashPoint SCCB Manager code is
641           substantial, so users of MultiMaster Host Adapters may not
642           wish to include it.
643
644 config VMWARE_PVSCSI
645         tristate "VMware PVSCSI driver support"
646         depends on PCI && SCSI && X86
647         help
648           This driver supports VMware's para virtualized SCSI HBA.
649           To compile this driver as a module, choose M here: the
650           module will be called vmw_pvscsi.
651
652 config HYPERV_STORAGE
653         tristate "Microsoft Hyper-V virtual storage driver"
654         depends on SCSI && HYPERV
655         default HYPERV
656         help
657           Select this option to enable the Hyper-V virtual storage driver.
658
659 config LIBFC
660         tristate "LibFC module"
661         select SCSI_FC_ATTRS
662         select CRC32
663         ---help---
664           Fibre Channel library module
665
666 config LIBFCOE
667         tristate "LibFCoE module"
668         select LIBFC
669         ---help---
670           Library for Fibre Channel over Ethernet module
671
672 config FCOE
673         tristate "FCoE module"
674         depends on PCI
675         select LIBFCOE
676         ---help---
677           Fibre Channel over Ethernet module
678
679 config FCOE_FNIC
680         tristate "Cisco FNIC Driver"
681         depends on PCI && X86
682         select LIBFCOE
683         help
684           This is support for the Cisco PCI-Express FCoE HBA.
685
686           To compile this driver as a module, choose M here and read
687           <file:Documentation/scsi/scsi.txt>.
688           The module will be called fnic.
689
690 config SCSI_DMX3191D
691         tristate "DMX3191D SCSI support"
692         depends on PCI && SCSI
693         select SCSI_SPI_ATTRS
694         help
695           This is support for Domex DMX3191D SCSI Host Adapters.
696
697           To compile this driver as a module, choose M here: the
698           module will be called dmx3191d.
699
700 config SCSI_DTC3280
701         tristate "DTC3180/3280 SCSI support"
702         depends on ISA && SCSI
703         select SCSI_SPI_ATTRS
704         select CHECK_SIGNATURE
705         help
706           This is support for DTC 3180/3280 SCSI Host Adapters.  Please read
707           the SCSI-HOWTO, available from
708           <http://www.tldp.org/docs.html#howto>, and the file
709           <file:Documentation/scsi/dtc3x80.txt>.
710
711           To compile this driver as a module, choose M here: the
712           module will be called dtc.
713
714 config SCSI_EATA
715         tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
716         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
717         ---help---
718           This driver supports all EATA/DMA-compliant SCSI host adapters.  DPT
719           ISA and all EISA I/O addresses are probed looking for the "EATA"
720           signature. The addresses of all the PCI SCSI controllers reported
721           by the PCI subsystem are probed as well.
722
723           You want to read the start of <file:drivers/scsi/eata.c> and the
724           SCSI-HOWTO, available from
725           <http://www.tldp.org/docs.html#howto>.
726
727           To compile this driver as a module, choose M here: the
728           module will be called eata.
729
730 config SCSI_EATA_TAGGED_QUEUE
731         bool "enable tagged command queueing"
732         depends on SCSI_EATA
733         help
734           This is a feature of SCSI-2 which improves performance: the host
735           adapter can send several SCSI commands to a device's queue even if
736           previous commands haven't finished yet.
737           This is equivalent to the "eata=tc:y" boot option.
738
739 config SCSI_EATA_LINKED_COMMANDS
740         bool "enable elevator sorting"
741         depends on SCSI_EATA
742         help
743           This option enables elevator sorting for all probed SCSI disks and
744           CD-ROMs. It definitely reduces the average seek distance when doing
745           random seeks, but this does not necessarily result in a noticeable
746           performance improvement: your mileage may vary...
747           This is equivalent to the "eata=lc:y" boot option.
748
749 config SCSI_EATA_MAX_TAGS
750         int "maximum number of queued commands"
751         depends on SCSI_EATA
752         default "16"
753         help
754           This specifies how many SCSI commands can be maximally queued for
755           each probed SCSI device. You should reduce the default value of 16
756           only if you have disks with buggy or limited tagged command support.
757           Minimum is 2 and maximum is 62. This value is also the window size
758           used by the elevator sorting option above. The effective value used
759           by the driver for each probed SCSI device is reported at boot time.
760           This is equivalent to the "eata=mq:8" boot option.
761
762 config SCSI_EATA_PIO
763         tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
764         depends on (ISA || EISA || PCI) && SCSI && BROKEN
765         ---help---
766           This driver supports all EATA-PIO protocol compliant SCSI Host
767           Adapters like the DPT PM2001 and the PM2012A.  EATA-DMA compliant
768           host adapters could also use this driver but are discouraged from
769           doing so, since this driver only supports hard disks and lacks
770           numerous features.  You might want to have a look at the SCSI-HOWTO,
771           available from <http://www.tldp.org/docs.html#howto>.
772
773           To compile this driver as a module, choose M here: the
774           module will be called eata_pio.
775
776 config SCSI_FUTURE_DOMAIN
777         tristate "Future Domain 16xx SCSI/AHA-2920A support"
778         depends on (ISA || PCI) && SCSI
779         select CHECK_SIGNATURE
780         ---help---
781           This is support for Future Domain's 16-bit SCSI host adapters
782           (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
783           other adapters based on the Future Domain chipsets (Quantum
784           ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
785           It is explained in section 3.7 of the SCSI-HOWTO, available from
786           <http://www.tldp.org/docs.html#howto>.
787
788           NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
789           and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
790           controller support"). This Future Domain driver works with the older
791           Adaptec AHA-2920A boards with a Future Domain chip on them.
792
793           To compile this driver as a module, choose M here: the
794           module will be called fdomain.
795
796 config SCSI_GDTH
797         tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
798         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
799         ---help---
800           Formerly called GDT SCSI Disk Array Controller Support.
801
802           This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI) 
803           manufactured by Intel Corporation/ICP vortex GmbH. It is documented
804           in the kernel source in <file:drivers/scsi/gdth.c> and
805           <file:drivers/scsi/gdth.h>.
806
807           To compile this driver as a module, choose M here: the
808           module will be called gdth.
809
810 config SCSI_ISCI
811         tristate "Intel(R) C600 Series Chipset SAS Controller"
812         depends on PCI && SCSI
813         depends on X86
814         select SCSI_SAS_LIBSAS
815         ---help---
816           This driver supports the 6Gb/s SAS capabilities of the storage
817           control unit found in the Intel(R) C600 series chipset.
818
819 config SCSI_GENERIC_NCR5380
820         tristate "Generic NCR5380/53c400 SCSI PIO support"
821         depends on ISA && SCSI
822         select SCSI_SPI_ATTRS
823         ---help---
824           This is a driver for the old NCR 53c80 series of SCSI controllers
825           on boards using PIO. Most boards such as the Trantor T130 fit this
826           category, along with a large number of ISA 8bit controllers shipped
827           for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
828           you should select the specific driver for that card rather than
829           generic 5380 support.
830
831           It is explained in section 3.8 of the SCSI-HOWTO, available from
832           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
833           of the box, you may have to change some settings in
834           <file:drivers/scsi/g_NCR5380.h>.
835
836           To compile this driver as a module, choose M here: the
837           module will be called g_NCR5380.
838
839 config SCSI_GENERIC_NCR5380_MMIO
840         tristate "Generic NCR5380/53c400 SCSI MMIO support"
841         depends on ISA && SCSI
842         select SCSI_SPI_ATTRS
843         ---help---
844           This is a driver for the old NCR 53c80 series of SCSI controllers
845           on boards using memory mapped I/O. 
846           It is explained in section 3.8 of the SCSI-HOWTO, available from
847           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
848           of the box, you may have to change some settings in
849           <file:drivers/scsi/g_NCR5380.h>.
850
851           To compile this driver as a module, choose M here: the
852           module will be called g_NCR5380_mmio.
853
854 config SCSI_GENERIC_NCR53C400
855         bool "Enable NCR53c400 extensions"
856         depends on SCSI_GENERIC_NCR5380
857         help
858           This enables certain optimizations for the NCR53c400 SCSI cards.
859           You might as well try it out.  Note that this driver will only probe
860           for the Trantor T130B in its default configuration; you might have
861           to pass a command line option to the kernel at boot time if it does
862           not detect your card.  See the file
863           <file:Documentation/scsi/g_NCR5380.txt> for details.
864
865 config SCSI_IPS
866         tristate "IBM ServeRAID support"
867         depends on PCI && SCSI
868         ---help---
869           This is support for the IBM ServeRAID hardware RAID controllers.
870           See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
871           and <http://www-947.ibm.com/support/entry/portal/docdisplay?brand=5000008&lndocid=SERV-RAID>
872           for more information.  If this driver does not work correctly
873           without modification please contact the author by email at
874           <ipslinux@adaptec.com>.
875
876           To compile this driver as a module, choose M here: the
877           module will be called ips.
878
879 config SCSI_IBMVSCSI
880         tristate "IBM Virtual SCSI support"
881         depends on PPC_PSERIES
882         select SCSI_SRP_ATTRS
883         help
884           This is the IBM POWER Virtual SCSI Client
885
886           To compile this driver as a module, choose M here: the
887           module will be called ibmvscsi.
888
889 config SCSI_IBMVSCSIS
890         tristate "IBM Virtual SCSI Server support"
891         depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
892         help
893           This is the SRP target driver for IBM pSeries virtual environments.
894
895           The userspace component needed to initialize the driver and
896           documentation can be found:
897
898           http://stgt.berlios.de/
899
900           To compile this driver as a module, choose M here: the
901           module will be called ibmvstgt.
902
903 config SCSI_IBMVFC
904         tristate "IBM Virtual FC support"
905         depends on PPC_PSERIES && SCSI
906         select SCSI_FC_ATTRS
907         help
908           This is the IBM POWER Virtual FC Client
909
910           To compile this driver as a module, choose M here: the
911           module will be called ibmvfc.
912
913 config SCSI_IBMVFC_TRACE
914         bool "enable driver internal trace"
915         depends on SCSI_IBMVFC
916         default y
917         help
918           If you say Y here, the driver will trace all commands issued
919           to the adapter. Performance impact is minimal. Trace can be
920           dumped using /sys/class/scsi_host/hostXX/trace.
921
922 config SCSI_INITIO
923         tristate "Initio 9100U(W) support"
924         depends on PCI && SCSI
925         help
926           This is support for the Initio 91XXU(W) SCSI host adapter.  Please
927           read the SCSI-HOWTO, available from
928           <http://www.tldp.org/docs.html#howto>.
929
930           To compile this driver as a module, choose M here: the
931           module will be called initio.
932
933 config SCSI_INIA100
934         tristate "Initio INI-A100U2W support"
935         depends on PCI && SCSI
936         help
937           This is support for the Initio INI-A100U2W SCSI host adapter.
938           Please read the SCSI-HOWTO, available from
939           <http://www.tldp.org/docs.html#howto>.
940
941           To compile this driver as a module, choose M here: the
942           module will be called a100u2w.
943
944 config SCSI_PPA
945         tristate "IOMEGA parallel port (ppa - older drives)"
946         depends on SCSI && PARPORT_PC
947         ---help---
948           This driver supports older versions of IOMEGA's parallel port ZIP
949           drive (a 100 MB removable media device).
950
951           Note that you can say N here if you have the SCSI version of the ZIP
952           drive: it will be supported automatically if you said Y to the
953           generic "SCSI disk support", above.
954
955           If you have the ZIP Plus drive or a more recent parallel port ZIP
956           drive (if the supplied cable with the drive is labeled "AutoDetect")
957           then you should say N here and Y to "IOMEGA parallel port (imm -
958           newer drives)", below.
959
960           For more information about this driver and how to use it you should
961           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
962           the SCSI-HOWTO, which is available from
963           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
964           you will still be able to use the parallel port for other tasks,
965           such as a printer; it is safe to compile both drivers into the
966           kernel.
967
968           To compile this driver as a module, choose M here: the
969           module will be called ppa.
970
971 config SCSI_IMM
972         tristate "IOMEGA parallel port (imm - newer drives)"
973         depends on SCSI && PARPORT_PC
974         ---help---
975           This driver supports newer versions of IOMEGA's parallel port ZIP
976           drive (a 100 MB removable media device).
977
978           Note that you can say N here if you have the SCSI version of the ZIP
979           drive: it will be supported automatically if you said Y to the
980           generic "SCSI disk support", above.
981
982           If you have the ZIP Plus drive or a more recent parallel port ZIP
983           drive (if the supplied cable with the drive is labeled "AutoDetect")
984           then you should say Y here; if you have an older ZIP drive, say N
985           here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
986
987           For more information about this driver and how to use it you should
988           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
989           the SCSI-HOWTO, which is available from
990           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
991           you will still be able to use the parallel port for other tasks,
992           such as a printer; it is safe to compile both drivers into the
993           kernel.
994
995           To compile this driver as a module, choose M here: the
996           module will be called imm.
997
998 config SCSI_IZIP_EPP16
999         bool "ppa/imm option - Use slow (but safe) EPP-16"
1000         depends on SCSI_PPA || SCSI_IMM
1001         ---help---
1002           EPP (Enhanced Parallel Port) is a standard for parallel ports which
1003           allows them to act as expansion buses that can handle up to 64
1004           peripheral devices.
1005
1006           Some parallel port chipsets are slower than their motherboard, and
1007           so we have to control the state of the chipset's FIFO queue every
1008           now and then to avoid data loss. This will be done if you say Y
1009           here.
1010
1011           Generally, saying Y is the safe option and slows things down a bit.
1012
1013 config SCSI_IZIP_SLOW_CTR
1014         bool "ppa/imm option - Assume slow parport control register"
1015         depends on SCSI_PPA || SCSI_IMM
1016         help
1017           Some parallel ports are known to have excessive delays between
1018           changing the parallel port control register and good data being
1019           available on the parallel port data/status register. This option
1020           forces a small delay (1.0 usec to be exact) after changing the
1021           control register to let things settle out. Enabling this option may
1022           result in a big drop in performance but some very old parallel ports
1023           (found in 386 vintage machines) will not work properly.
1024
1025           Generally, saying N is fine.
1026
1027 config SCSI_NCR53C406A
1028         tristate "NCR53c406a SCSI support"
1029         depends on ISA && SCSI
1030         help
1031           This is support for the NCR53c406a SCSI host adapter.  For user
1032           configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
1033           in the kernel source.  Also read the SCSI-HOWTO, available from
1034           <http://www.tldp.org/docs.html#howto>.
1035
1036           To compile this driver as a module, choose M here: the
1037           module will be called NCR53c406.
1038
1039 config SCSI_NCR_D700
1040         tristate "NCR Dual 700 MCA SCSI support"
1041         depends on MCA && SCSI
1042         select SCSI_SPI_ATTRS
1043         help
1044           This is a driver for the MicroChannel Dual 700 card produced by
1045           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1046           tries to negotiate sync and uses tag command queueing.
1047
1048           Unless you have an NCR manufactured machine, the chances are that
1049           you do not have this SCSI card, so say N.
1050
1051 config SCSI_LASI700
1052         tristate "HP Lasi SCSI support for 53c700/710"
1053         depends on GSC && SCSI
1054         select SCSI_SPI_ATTRS
1055         help
1056           This is a driver for the SCSI controller in the Lasi chip found in
1057           many PA-RISC workstations & servers.  If you do not know whether you
1058           have a Lasi chip, it is safe to say "Y" here.
1059
1060 config SCSI_SNI_53C710
1061         tristate "SNI RM SCSI support for 53c710"
1062         depends on SNI_RM && SCSI
1063         select SCSI_SPI_ATTRS
1064         select 53C700_LE_ON_BE
1065         help
1066           This is a driver for the onboard SCSI controller found in older
1067           SNI RM workstations & servers.
1068
1069 config 53C700_LE_ON_BE
1070         bool
1071         depends on SCSI_LASI700
1072         default y
1073
1074 config SCSI_STEX
1075         tristate "Promise SuperTrak EX Series support"
1076         depends on PCI && SCSI
1077         ---help---
1078           This driver supports Promise SuperTrak EX series storage controllers.
1079
1080           Promise provides Linux RAID configuration utility for these
1081           controllers. Please visit <http://www.promise.com> to download.
1082
1083           To compile this driver as a module, choose M here: the
1084           module will be called stex.
1085
1086 config 53C700_BE_BUS
1087         bool
1088         depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
1089         default y
1090
1091 config SCSI_SYM53C8XX_2
1092         tristate "SYM53C8XX Version 2 SCSI support"
1093         depends on PCI && SCSI
1094         select SCSI_SPI_ATTRS
1095         ---help---
1096           This driver supports the whole NCR53C8XX/SYM53C8XX family of
1097           PCI-SCSI controllers.  It also supports the subset of LSI53C10XX
1098           Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
1099           language.  It does not support LSI53C10XX Ultra-320 PCI-X SCSI
1100           controllers; you need to use the Fusion MPT driver for that.
1101
1102           Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
1103           information.
1104
1105 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
1106         int "DMA addressing mode"
1107         depends on SCSI_SYM53C8XX_2
1108         default "1"
1109         ---help---
1110           This option only applies to PCI-SCSI chips that are PCI DAC
1111           capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
1112
1113           When set to 0, the driver will program the chip to only perform
1114           32-bit DMA.  When set to 1, the chip will be able to perform DMA
1115           to addresses up to 1TB.  When set to 2, the driver supports the
1116           full 64-bit DMA address range, but can only address 16 segments
1117           of 4 GB each.  This limits the total addressable range to 64 GB.
1118
1119           Most machines with less than 4GB of memory should use a setting
1120           of 0 for best performance.  If your machine has 4GB of memory
1121           or more, you should set this option to 1 (the default).
1122
1123           The still experimental value 2 (64 bit DMA addressing with 16
1124           x 4GB segments limitation) can be used on systems that require
1125           PCI address bits past bit 39 to be set for the addressing of
1126           memory using PCI DAC cycles.
1127
1128 config SCSI_SYM53C8XX_DEFAULT_TAGS
1129         int "Default tagged command queue depth"
1130         depends on SCSI_SYM53C8XX_2
1131         default "16"
1132         help
1133           This is the default value of the command queue depth the
1134           driver will announce to the generic SCSI layer for devices
1135           that support tagged command queueing. This value can be changed
1136           from the boot command line.  This is a soft limit that cannot
1137           exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
1138
1139 config SCSI_SYM53C8XX_MAX_TAGS
1140         int "Maximum number of queued commands"
1141         depends on SCSI_SYM53C8XX_2
1142         default "64"
1143         help
1144           This option allows you to specify the maximum number of commands
1145           that can be queued to any device, when tagged command queuing is
1146           possible. The driver supports up to 256 queued commands per device.
1147           This value is used as a compiled-in hard limit.
1148
1149 config SCSI_SYM53C8XX_MMIO
1150         bool "Use memory mapped IO"
1151         depends on SCSI_SYM53C8XX_2
1152         default y
1153         help
1154           Memory mapped IO is faster than Port IO.  Most people should
1155           answer Y here, but some machines may have problems.  If you have
1156           to answer N here, please report the problem to the maintainer.
1157
1158 config SCSI_IPR
1159         tristate "IBM Power Linux RAID adapter support"
1160         depends on PCI && SCSI && ATA
1161         select FW_LOADER
1162         ---help---
1163           This driver supports the IBM Power Linux family RAID adapters.
1164           This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1165           as IBM iSeries 5702, 5703, 5709, and 570A.
1166
1167 config SCSI_IPR_TRACE
1168         bool "enable driver internal trace"
1169         depends on SCSI_IPR
1170         default y
1171         help
1172           If you say Y here, the driver will trace all commands issued
1173           to the adapter. Performance impact is minimal. Trace can be
1174           dumped using /sys/bus/class/scsi_host/hostXX/trace.
1175
1176 config SCSI_IPR_DUMP
1177         bool "enable adapter dump support"
1178         depends on SCSI_IPR
1179         default y
1180         help
1181           If you say Y here, the driver will support adapter crash dump.
1182           If you enable this support, the iprdump daemon can be used
1183           to capture adapter failure analysis information.
1184
1185 config SCSI_ZALON
1186         tristate "Zalon SCSI support"
1187         depends on GSC && SCSI
1188         select SCSI_SPI_ATTRS
1189         help
1190           The Zalon is a GSC/HSC bus interface chip that sits between the
1191           PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1192           C110, J200, J210 and some D, K & R-class machines.  It's also
1193           used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1194           Say Y here if you have one of these machines or cards.
1195
1196 config SCSI_NCR_Q720
1197         tristate "NCR Quad 720 MCA SCSI support"
1198         depends on MCA && SCSI
1199         select SCSI_SPI_ATTRS
1200         help
1201           This is a driver for the MicroChannel Quad 720 card produced by
1202           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1203           tries to negotiate sync and uses tag command queueing.
1204
1205           Unless you have an NCR manufactured machine, the chances are that
1206           you do not have this SCSI card, so say N.
1207
1208 config SCSI_NCR53C8XX_DEFAULT_TAGS
1209         int "default tagged command queue depth"
1210         depends on SCSI_ZALON || SCSI_NCR_Q720
1211         default "8"
1212         ---help---
1213           "Tagged command queuing" is a feature of SCSI-2 which improves
1214           performance: the host adapter can send several SCSI commands to a
1215           device's queue even if previous commands haven't finished yet.
1216           Because the device is intelligent, it can optimize its operations
1217           (like head positioning) based on its own request queue. Some SCSI
1218           devices don't implement this properly; if you want to disable this
1219           feature, enter 0 or 1 here (it doesn't matter which).
1220
1221           The default value is 8 and should be supported by most hard disks.
1222           This value can be overridden from the boot command line using the
1223           'tags' option as follows (example):
1224           'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1225           4, set queue depth to 16 for target 2 and target 3 on controller 0
1226           and set queue depth to 10 for target 0 / lun 2 on controller 1.
1227
1228           The normal answer therefore is to go with the default 8 and to use
1229           a boot command line option for devices that need to use a different
1230           command queue depth.
1231
1232           There is no safe option other than using good SCSI devices.
1233
1234 config SCSI_NCR53C8XX_MAX_TAGS
1235         int "maximum number of queued commands"
1236         depends on SCSI_ZALON || SCSI_NCR_Q720
1237         default "32"
1238         ---help---
1239           This option allows you to specify the maximum number of commands
1240           that can be queued to any device, when tagged command queuing is
1241           possible. The default value is 32. Minimum is 2, maximum is 64.
1242           Modern hard disks are able to support 64 tags and even more, but
1243           do not seem to be faster when more than 32 tags are being used.
1244
1245           So, the normal answer here is to go with the default value 32 unless
1246           you are using very large hard disks with large cache (>= 1 MB) that
1247           are able to take advantage of more than 32 tagged commands.
1248
1249           There is no safe option and the default answer is recommended.
1250
1251 config SCSI_NCR53C8XX_SYNC
1252         int "synchronous transfers frequency in MHz"
1253         depends on SCSI_ZALON || SCSI_NCR_Q720
1254         default "20"
1255         ---help---
1256           The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1257           rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80.  The numbers
1258           are respectively the maximum data transfer rates in mega-transfers
1259           per second for each class.  For example, a FAST-20 Wide 16 device is
1260           able to transfer data at 20 million 16 bit packets per second for a
1261           total rate of 40 MB/s.
1262
1263           You may specify 0 if you want to only use asynchronous data
1264           transfers. This is the safest and slowest option. Otherwise, specify
1265           a value between 5 and 80, depending on the capability of your SCSI
1266           controller.  The higher the number, the faster the data transfer.
1267           Note that 80 should normally be ok since the driver decreases the
1268           value automatically according to the controller's capabilities.
1269
1270           Your answer to this question is ignored for controllers with NVRAM,
1271           since the driver will get this information from the user set-up.  It
1272           also can be overridden using a boot setup option, as follows
1273           (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1274           for FAST-20 synchronous data transfer (20 mega-transfers per
1275           second).
1276
1277           The normal answer therefore is not to go with the default but to
1278           select the maximum value 80 allowing the driver to use the maximum
1279           value supported by each controller. If this causes problems with
1280           your SCSI devices, you should come back and decrease the value.
1281
1282           There is no safe option other than using good cabling, right
1283           terminations and SCSI conformant devices.
1284
1285 config SCSI_NCR53C8XX_NO_DISCONNECT
1286         bool "not allow targets to disconnect"
1287         depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1288         help
1289           This option is only provided for safety if you suspect some SCSI
1290           device of yours to not support properly the target-disconnect
1291           feature. In that case, you would say Y here. In general however, to
1292           not allow targets to disconnect is not reasonable if there is more
1293           than 1 device on a SCSI bus. The normal answer therefore is N.
1294
1295 config SCSI_PAS16
1296         tristate "PAS16 SCSI support"
1297         depends on ISA && SCSI
1298         select SCSI_SPI_ATTRS
1299         ---help---
1300           This is support for a SCSI host adapter.  It is explained in section
1301           3.10 of the SCSI-HOWTO, available from
1302           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1303           of the box, you may have to change some settings in
1304           <file:drivers/scsi/pas16.h>.
1305
1306           To compile this driver as a module, choose M here: the
1307           module will be called pas16.
1308
1309 config SCSI_QLOGIC_FAS
1310         tristate "Qlogic FAS SCSI support"
1311         depends on ISA && SCSI
1312         ---help---
1313           This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1314           FastSCSI! cards as well as any other card based on the FASXX chip
1315           (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1316
1317           This driver does NOT support the PCI versions of these cards. The
1318           PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1319           SCSI support"), below.
1320
1321           Information about this driver is contained in
1322           <file:Documentation/scsi/qlogicfas.txt>.  You should also read the
1323           SCSI-HOWTO, available from
1324           <http://www.tldp.org/docs.html#howto>.
1325
1326           To compile this driver as a module, choose M here: the
1327           module will be called qlogicfas.
1328
1329 config SCSI_QLOGIC_1280
1330         tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
1331         depends on PCI && SCSI
1332         help
1333           Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
1334
1335           To compile this driver as a module, choose M here: the
1336           module will be called qla1280.
1337
1338 config SCSI_QLOGICPTI
1339         tristate "PTI Qlogic, ISP Driver"
1340         depends on SBUS && SCSI
1341         help
1342           This driver supports SBUS SCSI controllers from PTI or QLogic. These
1343           controllers are known under Solaris as qpti and in the openprom as
1344           PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1345           driven by a different driver.
1346
1347           To compile this driver as a module, choose M here: the
1348           module will be called qlogicpti.
1349
1350 source "drivers/scsi/qla2xxx/Kconfig"
1351 source "drivers/scsi/qla4xxx/Kconfig"
1352
1353 config SCSI_LPFC
1354         tristate "Emulex LightPulse Fibre Channel Support"
1355         depends on PCI && SCSI
1356         select SCSI_FC_ATTRS
1357         select CRC_T10DIF
1358         help
1359           This lpfc driver supports the Emulex LightPulse
1360           Family of Fibre Channel PCI host adapters.
1361
1362 config SCSI_LPFC_DEBUG_FS
1363         bool "Emulex LightPulse Fibre Channel debugfs Support"
1364         depends on SCSI_LPFC && DEBUG_FS
1365         help
1366           This makes debugging information from the lpfc driver
1367           available via the debugfs filesystem.
1368
1369 config SCSI_SIM710
1370         tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1371         depends on (EISA || MCA) && SCSI
1372         select SCSI_SPI_ATTRS
1373         ---help---
1374           This driver is for NCR53c710 based SCSI host adapters.
1375
1376           It currently supports Compaq EISA cards and NCR MCA cards
1377
1378 config SCSI_SYM53C416
1379         tristate "Symbios 53c416 SCSI support"
1380         depends on ISA && SCSI
1381         ---help---
1382           This is support for the sym53c416 SCSI host adapter, the SCSI
1383           adapter that comes with some HP scanners. This driver requires that
1384           the sym53c416 is configured first using some sort of PnP
1385           configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1386           are using isapnp then you need to compile this driver as a module
1387           and then load it using insmod after isapnp has run. The parameters
1388           of the configured card(s) should be passed to the driver. The format
1389           is:
1390
1391           insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1392
1393           To compile this driver as a module, choose M here: the
1394           module will be called sym53c416.
1395
1396 config SCSI_DC395x
1397         tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support"
1398         depends on PCI && SCSI
1399         ---help---
1400           This driver supports PCI SCSI host adapters based on the ASIC
1401           TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1402
1403           This driver works, but is still in experimental status. So better
1404           have a bootable disk and a backup in case of emergency.
1405
1406           Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1407
1408           To compile this driver as a module, choose M here: the
1409           module will be called dc395x.
1410
1411 config SCSI_DC390T
1412         tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
1413         depends on PCI && SCSI
1414         ---help---
1415           This driver supports PCI SCSI host adapters based on the Am53C974A
1416           chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1417           PCscsi/PCnet (Am53/79C974) solutions.
1418
1419           Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1420
1421           Note that this driver does NOT support Tekram DC390W/U/F, which are
1422           based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1423
1424           To compile this driver as a module, choose M here: the
1425           module will be called tmscsim.
1426
1427 config SCSI_T128
1428         tristate "Trantor T128/T128F/T228 SCSI support"
1429         depends on ISA && SCSI
1430         select SCSI_SPI_ATTRS
1431         select CHECK_SIGNATURE
1432         ---help---
1433           This is support for a SCSI host adapter. It is explained in section
1434           3.11 of the SCSI-HOWTO, available from
1435           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1436           of the box, you may have to change some settings in
1437           <file:drivers/scsi/t128.h>.  Note that Trantor was purchased by
1438           Adaptec, and some former Trantor products are being sold under the
1439           Adaptec name.
1440
1441           To compile this driver as a module, choose M here: the
1442           module will be called t128.
1443
1444 config SCSI_U14_34F
1445         tristate "UltraStor 14F/34F support"
1446         depends on ISA && SCSI && ISA_DMA_API
1447         ---help---
1448           This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1449           The source at <file:drivers/scsi/u14-34f.c> contains some
1450           information about this hardware.  If the driver doesn't work out of
1451           the box, you may have to change some settings in
1452           <file: drivers/scsi/u14-34f.c>.  Read the SCSI-HOWTO, available from
1453           <http://www.tldp.org/docs.html#howto>.  Note that there is also
1454           another driver for the same hardware: "UltraStor SCSI support",
1455           below.  You should say Y to both only if you want 24F support as
1456           well.
1457
1458           To compile this driver as a module, choose M here: the
1459           module will be called u14-34f.
1460
1461 config SCSI_U14_34F_TAGGED_QUEUE
1462         bool "enable tagged command queueing"
1463         depends on SCSI_U14_34F
1464         help
1465           This is a feature of SCSI-2 which improves performance: the host
1466           adapter can send several SCSI commands to a device's queue even if
1467           previous commands haven't finished yet.
1468           This is equivalent to the "u14-34f=tc:y" boot option.
1469
1470 config SCSI_U14_34F_LINKED_COMMANDS
1471         bool "enable elevator sorting"
1472         depends on SCSI_U14_34F
1473         help
1474           This option enables elevator sorting for all probed SCSI disks and
1475           CD-ROMs. It definitely reduces the average seek distance when doing
1476           random seeks, but this does not necessarily result in a noticeable
1477           performance improvement: your mileage may vary...
1478           This is equivalent to the "u14-34f=lc:y" boot option.
1479
1480 config SCSI_U14_34F_MAX_TAGS
1481         int "maximum number of queued commands"
1482         depends on SCSI_U14_34F
1483         default "8"
1484         help
1485           This specifies how many SCSI commands can be maximally queued for
1486           each probed SCSI device. You should reduce the default value of 8
1487           only if you have disks with buggy or limited tagged command support.
1488           Minimum is 2 and maximum is 14. This value is also the window size
1489           used by the elevator sorting option above. The effective value used
1490           by the driver for each probed SCSI device is reported at boot time.
1491           This is equivalent to the "u14-34f=mq:8" boot option.
1492
1493 config SCSI_ULTRASTOR
1494         tristate "UltraStor SCSI support"
1495         depends on X86 && ISA && SCSI
1496         ---help---
1497           This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1498           adapter family.  This driver is explained in section 3.12 of the
1499           SCSI-HOWTO, available from
1500           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1501           of the box, you may have to change some settings in
1502           <file:drivers/scsi/ultrastor.h>.
1503
1504           Note that there is also another driver for the same hardware:
1505           "UltraStor 14F/34F support", above.
1506
1507           To compile this driver as a module, choose M here: the
1508           module will be called ultrastor.
1509
1510 config SCSI_NSP32
1511         tristate "Workbit NinjaSCSI-32Bi/UDE support"
1512         depends on PCI && SCSI && !64BIT
1513         help
1514           This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1515           SCSI host adapter. Please read the SCSI-HOWTO, available from
1516           <http://www.tldp.org/docs.html#howto>.
1517
1518           To compile this driver as a module, choose M here: the
1519           module will be called nsp32.
1520
1521 config SCSI_DEBUG
1522         tristate "SCSI debugging host simulator"
1523         depends on SCSI
1524         select CRC_T10DIF
1525         help
1526           This is a host adapter simulator that can simulate multiple hosts
1527           each with multiple dummy SCSI devices (disks). It defaults to one
1528           host adapter with one dummy SCSI disk. Each dummy disk uses kernel
1529           RAM as storage (i.e. it is a ramdisk). To save space when multiple
1530           dummy disks are simulated, they share the same kernel RAM for 
1531           their storage. See <http://sg.danny.cz/sg/sdebug26.html> for more
1532           information. This driver is primarily of use to those testing the
1533           SCSI and block subsystems. If unsure, say N.
1534
1535 config SCSI_MESH
1536         tristate "MESH (Power Mac internal SCSI) support"
1537         depends on PPC32 && PPC_PMAC && SCSI
1538         help
1539           Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1540           SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1541           other Power Macintoshes do). Say Y to include support for this SCSI
1542           adaptor.
1543
1544           To compile this driver as a module, choose M here: the
1545           module will be called mesh.
1546
1547 config SCSI_MESH_SYNC_RATE
1548         int "maximum synchronous transfer rate (MB/s) (0 = async)"
1549         depends on SCSI_MESH
1550         default "5"
1551         help
1552           On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1553           drives a bus which is entirely internal to the machine (such as the
1554           7500, 7600, 8500, etc.), the MESH is capable of synchronous
1555           operation at up to 10 MB/s. On machines where the SCSI bus
1556           controlled by the MESH can have external devices connected, it is
1557           usually rated at 5 MB/s. 5 is a safe value here unless you know the
1558           MESH SCSI bus is internal only; in that case you can say 10. Say 0
1559           to disable synchronous operation.
1560
1561 config SCSI_MESH_RESET_DELAY_MS
1562         int "initial bus reset delay (ms) (0 = no reset)"
1563         depends on SCSI_MESH
1564         default "4000"
1565
1566 config SCSI_MAC53C94
1567         tristate "53C94 (Power Mac external SCSI) support"
1568         depends on PPC32 && PPC_PMAC && SCSI
1569         help
1570           On Power Macintoshes (and clones) with two SCSI buses, the external
1571           SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1572           machines which only have one SCSI bus, such as the 7200, also use
1573           the 53C94. Say Y to include support for the 53C94.
1574
1575           To compile this driver as a module, choose M here: the
1576           module will be called mac53c94.
1577
1578 source "drivers/scsi/arm/Kconfig"
1579
1580 config JAZZ_ESP
1581         bool "MIPS JAZZ FAS216 SCSI support"
1582         depends on MACH_JAZZ && SCSI
1583         select SCSI_SPI_ATTRS
1584         help
1585           This is the driver for the onboard SCSI host adapter of MIPS Magnum
1586           4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1587           systems.
1588
1589 config A3000_SCSI
1590         tristate "A3000 WD33C93A support"
1591         depends on AMIGA && SCSI
1592         help
1593           If you have an Amiga 3000 and have SCSI devices connected to the
1594           built-in SCSI controller, say Y. Otherwise, say N.
1595
1596           To compile this driver as a module, choose M here: the
1597           module will be called a3000.
1598
1599 config A2091_SCSI
1600         tristate "A2091/A590 WD33C93A support"
1601         depends on ZORRO && SCSI
1602         help
1603           If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1604           say N.
1605
1606           To compile this driver as a module, choose M here: the
1607           module will be called a2091.
1608
1609 config GVP11_SCSI
1610         tristate "GVP Series II WD33C93A support"
1611         depends on ZORRO && SCSI
1612         ---help---
1613           If you have a Great Valley Products Series II SCSI controller,
1614           answer Y. Also say Y if you have a later model of GVP SCSI
1615           controller (such as the GVP A4008 or a Combo board). Otherwise,
1616           answer N. This driver does NOT work for the T-Rex series of
1617           accelerators from TekMagic and GVP-M.
1618
1619           To compile this driver as a module, choose M here: the
1620           module will be called gvp11.
1621
1622 config SCSI_A4000T
1623         tristate "A4000T NCR53c710 SCSI support"
1624         depends on AMIGA && SCSI
1625         select SCSI_SPI_ATTRS
1626         help
1627           If you have an Amiga 4000T and have SCSI devices connected to the
1628           built-in SCSI controller, say Y. Otherwise, say N.
1629
1630           To compile this driver as a module, choose M here: the
1631           module will be called a4000t.
1632
1633 config SCSI_ZORRO7XX
1634         tristate "Zorro NCR53c710 SCSI support"
1635         depends on ZORRO && SCSI
1636         select SCSI_SPI_ATTRS
1637         help
1638           Support for various NCR53c710-based SCSI controllers on Zorro
1639           expansion boards for the Amiga.
1640           This includes:
1641             - the Amiga 4091 Zorro III SCSI-2 controller,
1642             - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1643               (info at
1644               <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1645             - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1646               accelerator card for the Amiga 1200,
1647             - the SCSI controller on the GVP Turbo 040/060 accelerator.
1648
1649 config ATARI_SCSI
1650         tristate "Atari native SCSI support"
1651         depends on ATARI && SCSI
1652         select SCSI_SPI_ATTRS
1653         select NVRAM
1654         ---help---
1655           If you have an Atari with built-in NCR5380 SCSI controller (TT,
1656           Falcon, ...) say Y to get it supported. Of course also, if you have
1657           a compatible SCSI controller (e.g. for Medusa).
1658
1659           To compile this driver as a module, choose M here: the
1660           module will be called atari_scsi.
1661
1662           This driver supports both styles of NCR integration into the
1663           system: the TT style (separate DMA), and the Falcon style (via
1664           ST-DMA, replacing ACSI).  It does NOT support other schemes, like
1665           in the Hades (without DMA).
1666
1667 config ATARI_SCSI_TOSHIBA_DELAY
1668         bool "Long delays for Toshiba CD-ROMs"
1669         depends on ATARI_SCSI
1670         help
1671           This option increases the delay after a SCSI arbitration to
1672           accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1673           use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1674           would impact performance a bit, so say N.
1675
1676 config ATARI_SCSI_RESET_BOOT
1677         bool "Reset SCSI-devices at boottime"
1678         depends on ATARI_SCSI
1679         help
1680           Reset the devices on your Atari whenever it boots.  This makes the
1681           boot process fractionally longer but may assist recovery from errors
1682           that leave the devices with SCSI operations partway completed.
1683
1684 config MAC_SCSI
1685         bool "Macintosh NCR5380 SCSI"
1686         depends on MAC && SCSI=y
1687         select SCSI_SPI_ATTRS
1688         help
1689           This is the NCR 5380 SCSI controller included on most of the 68030
1690           based Macintoshes.  If you have one of these say Y and read the
1691           SCSI-HOWTO, available from
1692           <http://www.tldp.org/docs.html#howto>.
1693
1694 config SCSI_MAC_ESP
1695         tristate "Macintosh NCR53c9[46] SCSI"
1696         depends on MAC && SCSI
1697         select SCSI_SPI_ATTRS
1698         help
1699           This is the NCR 53c9x SCSI controller found on most of the 68040
1700           based Macintoshes.
1701
1702           To compile this driver as a module, choose M here: the module
1703           will be called mac_esp.
1704
1705 config MVME147_SCSI
1706         bool "WD33C93 SCSI driver for MVME147"
1707         depends on MVME147 && SCSI=y
1708         select SCSI_SPI_ATTRS
1709         help
1710           Support for the on-board SCSI controller on the Motorola MVME147
1711           single-board computer.
1712
1713 config MVME16x_SCSI
1714         tristate "NCR53C710 SCSI driver for MVME16x"
1715         depends on MVME16x && SCSI
1716         select SCSI_SPI_ATTRS
1717         help
1718           The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1719           SCSI controller chip.  Almost everyone using one of these boards
1720           will want to say Y to this question.
1721
1722 config BVME6000_SCSI
1723         tristate "NCR53C710 SCSI driver for BVME6000"
1724         depends on BVME6000 && SCSI
1725         select SCSI_SPI_ATTRS
1726         help
1727           The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1728           SCSI controller chip.  Almost everyone using one of these boards
1729           will want to say Y to this question.
1730
1731 config SUN3_SCSI
1732         tristate "Sun3 NCR5380 SCSI"
1733         depends on SUN3 && SCSI
1734         select SCSI_SPI_ATTRS
1735         help
1736           This option will enable support for the OBIO (onboard io) NCR5380
1737           SCSI controller found in the Sun 3/50 and 3/60, as well as for
1738           "Sun3" type VME scsi controllers also based on the NCR5380.
1739           General Linux information on the Sun 3 series (now discontinued)
1740           is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1741
1742 config SUN3X_ESP
1743         bool "Sun3x ESP SCSI"
1744         depends on SUN3X && SCSI=y
1745         select SCSI_SPI_ATTRS
1746         help
1747           The ESP was an on-board SCSI controller used on Sun 3/80
1748           machines.  Say Y here to compile in support for it.
1749
1750 config SCSI_SUNESP
1751         tristate "Sparc ESP Scsi Driver"
1752         depends on SBUS && SCSI
1753         select SCSI_SPI_ATTRS
1754         help
1755           This is the driver for the Sun ESP SCSI host adapter. The ESP
1756           chipset is present in most SPARC SBUS-based computers and
1757           supports the Emulex family of ESP SCSI chips (esp100, esp100A,
1758           esp236, fas101, fas236) as well as the Qlogic fas366 SCSI chip.
1759
1760           To compile this driver as a module, choose M here: the
1761           module will be called sun_esp.
1762
1763 config ZFCP
1764         tristate "FCP host bus adapter driver for IBM eServer zSeries"
1765         depends on S390 && QDIO && SCSI
1766         select SCSI_FC_ATTRS
1767         help
1768           If you want to access SCSI devices attached to your IBM eServer
1769           zSeries by means of Fibre Channel interfaces say Y.
1770           For details please refer to the documentation provided by IBM at
1771           <http://oss.software.ibm.com/developerworks/opensource/linux390>
1772
1773           This driver is also available as a module. This module will be
1774           called zfcp. If you want to compile it as a module, say M here
1775           and read <file:Documentation/kbuild/modules.txt>.
1776
1777 config SCSI_PMCRAID
1778         tristate "PMC SIERRA Linux MaxRAID adapter support"
1779         depends on PCI && SCSI && NET
1780         ---help---
1781           This driver supports the PMC SIERRA MaxRAID adapters.
1782
1783 config SCSI_PM8001
1784         tristate "PMC-Sierra SPC 8001 SAS/SATA Based Host Adapter driver"
1785         depends on PCI && SCSI
1786         select SCSI_SAS_LIBSAS
1787         help
1788           This driver supports PMC-Sierra PCIE SAS/SATA 8x6G SPC 8001 chip
1789           based host adapters.
1790
1791 config SCSI_SRP
1792         tristate "SCSI RDMA Protocol helper library"
1793         depends on SCSI && PCI
1794         select SCSI_TGT
1795         help
1796           If you wish to use SRP target drivers, say Y.
1797
1798           To compile this driver as a module, choose M here: the
1799           module will be called libsrp.
1800
1801 config SCSI_BFA_FC
1802         tristate "Brocade BFA Fibre Channel Support"
1803         depends on PCI && SCSI
1804         select SCSI_FC_ATTRS
1805         help
1806           This bfa driver supports all Brocade PCIe FC/FCOE host adapters.
1807
1808           To compile this driver as a module, choose M here. The module will
1809           be called bfa.
1810
1811 config SCSI_VIRTIO
1812         tristate "virtio-scsi support"
1813         depends on VIRTIO
1814         help
1815           This is the virtual HBA driver for virtio.  If the kernel will
1816           be used in a virtual machine, say Y or M.
1817
1818 source "drivers/scsi/csiostor/Kconfig"
1819
1820 endif # SCSI_LOWLEVEL
1821
1822 source "drivers/scsi/pcmcia/Kconfig"
1823
1824 source "drivers/scsi/device_handler/Kconfig"
1825
1826 source "drivers/scsi/osd/Kconfig"
1827
1828 endmenu