2 tristate "Memory Technology Device (MTD) support"
5 Memory Technology Devices are flash, RAM and similar chips, often
6 used for solid state file systems on embedded devices. This option
7 will provide the generic support for MTD drivers to register
8 themselves with the kernel and for potential users of MTD devices
9 to enumerate the devices which are present and obtain a handle on
10 them. It will also allow you to select individual drivers for
11 particular hardware and users of MTD devices. If unsure, say N.
16 tristate "MTD tests support (DANGEROUS)"
19 This option includes various MTD tests into compilation. The tests
20 should normally be compiled as kernel modules. The modules perform
21 various checks and verifications when loaded.
23 WARNING: some of the tests will ERASE entire MTD device which they
24 test. Do not use these tests unless you really know what you do.
26 config MTD_CMDLINE_PARTS
27 tristate "Command line partition table parsing"
30 Allow generic configuration of the MTD partition tables via the kernel
31 command line. Multiple flash resources are supported for hardware where
32 different kinds of flash memory are available.
34 You will still need the parsing functions to be called by the driver
35 for your particular device. It won't happen automatically. The
36 SA1100 map driver (CONFIG_MTD_SA1100) has an option for this, for
39 The format for the command line is as follows:
41 mtdparts=<mtddef>[;<mtddef]
42 <mtddef> := <mtd-id>:<partdef>[,<partdef>]
43 <partdef> := <size>[@offset][<name>][ro]
44 <mtd-id> := unique id used in mapping driver/device
45 <size> := standard linux memsize OR "-" to denote all
49 Due to the way Linux handles the command line, no spaces are
50 allowed in the partition definition, including mtd id's and partition
55 1 flash resource (mtd-id "sa1100"), with 1 single writable partition:
58 Same flash, but 2 named partitions, the first one being read-only:
59 mtdparts=sa1100:256k(ARMboot)ro,-(root)
64 tristate "OpenFirmware partitioning information support"
68 This provides a partition parsing function which derives
69 the partition map from the children of the flash node,
70 as described in Documentation/devicetree/bindings/mtd/partition.txt.
73 tristate "TI AR7 partitioning support"
75 TI AR7 partitioning support
77 config MTD_BCM63XX_PARTS
78 tristate "BCM63XX CFE partitioning support"
79 depends on BCM63XX || BMIPS_GENERIC || COMPILE_TEST
81 select MTD_PARSER_IMAGETAG
83 This provides partition parsing for BCM63xx devices with CFE
86 config MTD_BCM47XX_PARTS
87 tristate "BCM47XX partitioning support"
88 depends on BCM47XX || ARCH_BCM_5301X
90 This provides partitions parser for devices based on BCM47xx
93 menu "Partition parsers"
94 source "drivers/mtd/parsers/Kconfig"
97 comment "User Modules And Translation Layers"
100 # MTD block device support is select'ed if needed
106 tristate "Caching block device access to MTD devices"
110 Although most flash chips have an erase size too large to be useful
111 as block devices, it is possible to use MTD devices which are based
112 on RAM chips in this manner. This block device is a user of MTD
113 devices performing that function.
115 At the moment, it is also required for the Journalling Flash File
116 System(s) to obtain a handle on the MTD device when it's mounted
117 (although JFFS and JFFS2 don't actually use any of the functionality
118 of the mtdblock device).
120 Later, it may be extended to perform read/erase/modify/write cycles
121 on flash chips to emulate a smaller block size. Needless to say,
122 this is very unsafe, but could be useful for file systems which are
123 almost never written to.
125 You do not need this option for use with the DiskOnChip devices. For
126 those, enable NFTL support (CONFIG_NFTL) instead.
129 tristate "Readonly block device access to MTD devices"
130 depends on MTD_BLOCK!=y && BLOCK
133 This allows you to mount read-only file systems (such as cramfs)
134 from an MTD device, without the overhead (and danger) of the caching
137 You do not need this option for use with the DiskOnChip devices. For
138 those, enable NFTL support (CONFIG_NFTL) instead.
141 tristate "FTL (Flash Translation Layer) support"
145 This provides support for the original Flash Translation Layer which
146 is part of the PCMCIA specification. It uses a kind of pseudo-
147 file system on a flash device to emulate a block device with
148 512-byte sectors, on top of which you put a 'normal' file system.
150 You may find that the algorithms used in this code are patented
151 unless you live in the Free World where software patents aren't
152 legal - in the USA you are only permitted to use this on PCMCIA
153 hardware, although under the terms of the GPL you're obviously
154 permitted to copy, modify and distribute the code as you wish. Just
158 tristate "NFTL (NAND Flash Translation Layer) support"
162 This provides support for the NAND Flash Translation Layer which is
163 used on M-Systems' DiskOnChip devices. It uses a kind of pseudo-
164 file system on a flash device to emulate a block device with
165 512-byte sectors, on top of which you put a 'normal' file system.
167 You may find that the algorithms used in this code are patented
168 unless you live in the Free World where software patents aren't
169 legal - in the USA you are only permitted to use this on DiskOnChip
170 hardware, although under the terms of the GPL you're obviously
171 permitted to copy, modify and distribute the code as you wish. Just
175 bool "Write support for NFTL"
178 Support for writing to the NAND Flash Translation Layer, as used
182 tristate "INFTL (Inverse NAND Flash Translation Layer) support"
186 This provides support for the Inverse NAND Flash Translation
187 Layer which is used on M-Systems' newer DiskOnChip devices. It
188 uses a kind of pseudo-file system on a flash device to emulate
189 a block device with 512-byte sectors, on top of which you put
190 a 'normal' file system.
192 You may find that the algorithms used in this code are patented
193 unless you live in the Free World where software patents aren't
194 legal - in the USA you are only permitted to use this on DiskOnChip
195 hardware, although under the terms of the GPL you're obviously
196 permitted to copy, modify and distribute the code as you wish. Just
200 tristate "Resident Flash Disk (Flash Translation Layer) support"
204 This provides support for the flash translation layer known
205 as the Resident Flash Disk (RFD), as used by the Embedded BIOS
206 of General Software. There is a blurb at:
208 http://www.gensw.com/pages/prod/bios/rfd.htm
211 tristate "NAND SSFDC (SmartMedia) read only translation layer"
215 This enables read only access to SmartMedia formatted NAND
216 flash. You can mount it with FAT file system.
219 tristate "SmartMedia/xD new translation layer"
222 select MTD_NAND_ECC_SW_HAMMING
224 This enables EXPERIMENTAL R/W support for SmartMedia/xD
225 FTL (Flash translation layer).
226 Write support is only lightly tested, therefore this driver
227 isn't recommended to use with valuable data (anyway if you have
228 valuable data, do backups regardless of software/hardware you
229 use, because you never know what will eat your data...)
230 If you only need R/O access, you can use older R/O driver
234 tristate "Log panic/oops to an MTD buffer"
236 This enables panic and oops messages to be logged to a circular
237 buffer in a flash partition where it can be read back at some
241 tristate "Swap on MTD device support"
242 depends on MTD && SWAP
245 Provides volatile block device driver on top of mtd partition
246 suitable for swapping. The mapping of written blocks is not saved.
247 The driver provides wear leveling by storing erase counter into the
250 config MTD_PARTITIONED_MASTER
251 bool "Retain master device when partitioned"
255 For historical reasons, by default, either a master is present or
256 several partitions are present, but not both. The concern was that
257 data listed in multiple partitions was dangerous; however, SCSI does
258 this and it is frequently useful for applications. This config option
259 leaves the master in even if the device is partitioned. It also makes
260 the parent of the partition device be the master device, rather than
261 what lies behind the master.
263 source "drivers/mtd/chips/Kconfig"
265 source "drivers/mtd/maps/Kconfig"
267 source "drivers/mtd/devices/Kconfig"
269 source "drivers/mtd/nand/Kconfig"
271 source "drivers/mtd/lpddr/Kconfig"
273 source "drivers/mtd/spi-nor/Kconfig"
275 source "drivers/mtd/ubi/Kconfig"
277 source "drivers/mtd/hyperbus/Kconfig"