Merge branch 'u-boot-sunxi/master' into 'u-boot-arm/master'
[platform/kernel/u-boot.git] / drivers / misc / cros_ec_lpc.c
1 /*
2  * Chromium OS cros_ec driver - LPC interface
3  *
4  * Copyright (c) 2012 The Chromium OS Authors.
5  *
6  * SPDX-License-Identifier:     GPL-2.0+
7  */
8
9 /*
10  * The Matrix Keyboard Protocol driver handles talking to the keyboard
11  * controller chip. Mostly this is for keyboard functions, but some other
12  * things have slipped in, so we provide generic services to talk to the
13  * KBC.
14  */
15
16 #include <common.h>
17 #include <command.h>
18 #include <cros_ec.h>
19 #include <asm/io.h>
20
21 #ifdef DEBUG_TRACE
22 #define debug_trace(fmt, b...)  debug(fmt, ##b)
23 #else
24 #define debug_trace(fmt, b...)
25 #endif
26
27 static int wait_for_sync(struct cros_ec_dev *dev)
28 {
29         unsigned long start;
30
31         start = get_timer(0);
32         while (inb(EC_LPC_ADDR_HOST_CMD) & EC_LPC_STATUS_BUSY_MASK) {
33                 if (get_timer(start) > 1000) {
34                         debug("%s: Timeout waiting for CROS_EC sync\n",
35                               __func__);
36                         return -1;
37                 }
38         }
39
40         return 0;
41 }
42
43 int cros_ec_lpc_command(struct cros_ec_dev *dev, uint8_t cmd, int cmd_version,
44                      const uint8_t *dout, int dout_len,
45                      uint8_t **dinp, int din_len)
46 {
47         const int cmd_addr = EC_LPC_ADDR_HOST_CMD;
48         const int data_addr = EC_LPC_ADDR_HOST_DATA;
49         const int args_addr = EC_LPC_ADDR_HOST_ARGS;
50         const int param_addr = EC_LPC_ADDR_HOST_PARAM;
51
52         struct ec_lpc_host_args args;
53         uint8_t *d;
54         int csum;
55         int i;
56
57         if (dout_len > EC_HOST_PARAM_SIZE) {
58                 debug("%s: Cannot send %d bytes\n", __func__, dout_len);
59                 return -1;
60         }
61
62         /* Fill in args */
63         args.flags = EC_HOST_ARGS_FLAG_FROM_HOST;
64         args.command_version = cmd_version;
65         args.data_size = dout_len;
66
67         /* Calculate checksum */
68         csum = cmd + args.flags + args.command_version + args.data_size;
69         for (i = 0, d = (uint8_t *)dout; i < dout_len; i++, d++)
70                 csum += *d;
71
72         args.checksum = (uint8_t)csum;
73
74         if (wait_for_sync(dev)) {
75                 debug("%s: Timeout waiting ready\n", __func__);
76                 return -1;
77         }
78
79         /* Write args */
80         for (i = 0, d = (uint8_t *)&args; i < sizeof(args); i++, d++)
81                 outb(*d, args_addr + i);
82
83         /* Write data, if any */
84         debug_trace("cmd: %02x, ver: %02x", cmd, cmd_version);
85         for (i = 0, d = (uint8_t *)dout; i < dout_len; i++, d++) {
86                 outb(*d, param_addr + i);
87                 debug_trace("%02x ", *d);
88         }
89
90         outb(cmd, cmd_addr);
91         debug_trace("\n");
92
93         if (wait_for_sync(dev)) {
94                 debug("%s: Timeout waiting for response\n", __func__);
95                 return -1;
96         }
97
98         /* Check result */
99         i = inb(data_addr);
100         if (i) {
101                 debug("%s: CROS_EC result code %d\n", __func__, i);
102                 return -i;
103         }
104
105         /* Read back args */
106         for (i = 0, d = (uint8_t *)&args; i < sizeof(args); i++, d++)
107                 *d = inb(args_addr + i);
108
109         /*
110          * If EC didn't modify args flags, then somehow we sent a new-style
111          * command to an old EC, which means it would have read its params
112          * from the wrong place.
113          */
114         if (!(args.flags & EC_HOST_ARGS_FLAG_TO_HOST)) {
115                 debug("%s: CROS_EC protocol mismatch\n", __func__);
116                 return -EC_RES_INVALID_RESPONSE;
117         }
118
119         if (args.data_size > din_len) {
120                 debug("%s: CROS_EC returned too much data %d > %d\n",
121                       __func__, args.data_size, din_len);
122                 return -EC_RES_INVALID_RESPONSE;
123         }
124
125         /* Read data, if any */
126         for (i = 0, d = (uint8_t *)dev->din; i < args.data_size; i++, d++) {
127                 *d = inb(param_addr + i);
128                 debug_trace("%02x ", *d);
129         }
130         debug_trace("\n");
131
132         /* Verify checksum */
133         csum = cmd + args.flags + args.command_version + args.data_size;
134         for (i = 0, d = (uint8_t *)dev->din; i < args.data_size; i++, d++)
135                 csum += *d;
136
137         if (args.checksum != (uint8_t)csum) {
138                 debug("%s: CROS_EC response has invalid checksum\n", __func__);
139                 return -EC_RES_INVALID_CHECKSUM;
140         }
141         *dinp = dev->din;
142
143         /* Return actual amount of data received */
144         return args.data_size;
145 }
146
147 /**
148  * Initialize LPC protocol.
149  *
150  * @param dev           CROS_EC device
151  * @param blob          Device tree blob
152  * @return 0 if ok, -1 on error
153  */
154 int cros_ec_lpc_init(struct cros_ec_dev *dev, const void *blob)
155 {
156         int byte, i;
157
158         /* See if we can find an EC at the other end */
159         byte = 0xff;
160         byte &= inb(EC_LPC_ADDR_HOST_CMD);
161         byte &= inb(EC_LPC_ADDR_HOST_DATA);
162         for (i = 0; i < EC_HOST_PARAM_SIZE && (byte == 0xff); i++)
163                 byte &= inb(EC_LPC_ADDR_HOST_PARAM + i);
164         if (byte == 0xff) {
165                 debug("%s: CROS_EC device not found on LPC bus\n",
166                         __func__);
167                 return -1;
168         }
169
170         return 0;
171 }
172
173 /*
174  * Test if LPC command args are supported.
175  *
176  * The cheapest way to do this is by looking for the memory-mapped
177  * flag.  This is faster than sending a new-style 'hello' command and
178  * seeing whether the EC sets the EC_HOST_ARGS_FLAG_FROM_HOST flag
179  * in args when it responds.
180  */
181 int cros_ec_lpc_check_version(struct cros_ec_dev *dev)
182 {
183         if (inb(EC_LPC_ADDR_MEMMAP + EC_MEMMAP_ID) == 'E' &&
184                         inb(EC_LPC_ADDR_MEMMAP + EC_MEMMAP_ID + 1)
185                                 == 'C' &&
186                         (inb(EC_LPC_ADDR_MEMMAP +
187                                 EC_MEMMAP_HOST_CMD_FLAGS) &
188                                 EC_HOST_CMD_FLAG_LPC_ARGS_SUPPORTED)) {
189                 return 0;
190         }
191
192         printf("%s: ERROR: old EC interface not supported\n", __func__);
193         return -1;
194 }