1 Generic Thermal Sysfs driver How To
2 ===================================
3
4 Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6 Updated: 2 January 2008
7
8 Copyright (c)  2008 Intel Corporation
9
10
11 0. Introduction
12
13 The generic thermal sysfs provides a set of interfaces for thermal zone
14 devices (sensors) and thermal cooling devices (fan, processor...) to register
15 with the thermal management solution and to be a part of it.
16
17 This how-to focuses on enabling new thermal zone and cooling devices to
18 participate in thermal management.
19 This solution is platform independent and any type of thermal zone devices
20 and cooling devices should be able to make use of the infrastructure.
21
22 The main task of the thermal sysfs driver is to expose thermal zone attributes
23 as well as cooling device attributes to the user space.
24 An intelligent thermal management application can make decisions based on
25 inputs from thermal zone attributes (the current temperature and trip point
26 temperature) and throttle appropriate devices.
27
28 [0-*]   denotes any positive number starting from 0
29 [1-*]   denotes any positive number starting from 1
30
31 1. thermal sysfs driver interface functions
32
33 1.1 thermal zone device interface
34 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name,
35                 int trips, int mask, void *devdata,
36                 struct thermal_zone_device_ops *ops)
37
38     This interface function adds a new thermal zone device (sensor) to
39     /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
40     thermal cooling devices registered at the same time.
41
42     name: the thermal zone name.
43     trips: the total number of trip points this thermal zone supports.
44     mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
45     devdata: device private data
46     ops: thermal zone device call-backs.
47         .bind: bind the thermal zone device with a thermal cooling device.
48         .unbind: unbind the thermal zone device with a thermal cooling device.
49         .get_temp: get the current temperature of the thermal zone.
50         .get_mode: get the current mode (user/kernel) of the thermal zone.
51             - "kernel" means thermal management is done in kernel.
52             - "user" will prevent kernel thermal driver actions upon trip points
53               so that user applications can take charge of thermal management.
54         .set_mode: set the mode (user/kernel) of the thermal zone.
55         .get_trip_type: get the type of certain trip point.
56         .get_trip_temp: get the temperature above which the certain trip point
57                         will be fired.
58
59 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
60
61     This interface function removes the thermal zone device.
62     It deletes the corresponding entry form /sys/class/thermal folder and
63     unbind all the thermal cooling devices it uses.
64
65 1.2 thermal cooling device interface
66 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
67                 void *devdata, struct thermal_cooling_device_ops *)
68
69     This interface function adds a new thermal cooling device (fan/processor/...)
70     to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
71     to all the thermal zone devices register at the same time.
72     name: the cooling device name.
73     devdata: device private data.
74     ops: thermal cooling devices call-backs.
75         .get_max_state: get the Maximum throttle state of the cooling device.
76         .get_cur_state: get the Current throttle state of the cooling device.
77         .set_cur_state: set the Current throttle state of the cooling device.
78
79 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
80
81     This interface function remove the thermal cooling device.
82     It deletes the corresponding entry form /sys/class/thermal folder and
83     unbind itself from all the thermal zone devices using it.
84
85 1.3 interface for binding a thermal zone device with a thermal cooling device
86 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
87                 int trip, struct thermal_cooling_device *cdev);
88
89     This interface function bind a thermal cooling device to the certain trip
90     point of a thermal zone device.
91     This function is usually called in the thermal zone device .bind callback.
92     tz: the thermal zone device
93     cdev: thermal cooling device
94     trip: indicates which trip point the cooling devices is associated with
95           in this thermal zone.
96
97 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
98                 int trip, struct thermal_cooling_device *cdev);
99
100     This interface function unbind a thermal cooling device from the certain
101     trip point of a thermal zone device. This function is usually called in
102     the thermal zone device .unbind callback.
103     tz: the thermal zone device
104     cdev: thermal cooling device
105     trip: indicates which trip point the cooling devices is associated with
106           in this thermal zone.
107
108 2. sysfs attributes structure
109
110 RO      read only value
111 RW      read/write value
112
113 Thermal sysfs attributes will be represented under /sys/class/thermal.
114 Hwmon sysfs I/F extension is also available under /sys/class/hwmon
115 if hwmon is compiled in or built as a module.
116
117 Thermal zone device sys I/F, created once it's registered:
118 /sys/class/thermal/thermal_zone[0-*]:
119     |---type:                   Type of the thermal zone
120     |---temp:                   Current temperature
121     |---mode:                   Working mode of the thermal zone
122     |---trip_point_[0-*]_temp:  Trip point temperature
123     |---trip_point_[0-*]_type:  Trip point type
124
125 Thermal cooling device sys I/F, created once it's registered:
126 /sys/class/thermal/cooling_device[0-*]:
127     |---type:                   Type of the cooling device(processor/fan/...)
128     |---max_state:              Maximum cooling state of the cooling device
129     |---cur_state:              Current cooling state of the cooling device
130
131
132 Then next two dynamic attributes are created/removed in pairs. They represent
133 the relationship between a thermal zone and its associated cooling device.
134 They are created/removed for each successful execution of
135 thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
136
137 /sys/class/thermal/thermal_zone[0-*]:
138     |---cdev[0-*]:              [0-*]th cooling device in current thermal zone
139     |---cdev[0-*]_trip_point:   Trip point that cdev[0-*] is associated with
140
141 Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
142 the generic thermal driver also creates a hwmon sysfs I/F for each _type_
143 of thermal zone device. E.g. the generic thermal driver registers one hwmon
144 class device and build the associated hwmon sysfs I/F for all the registered
145 ACPI thermal zones.
146
147 /sys/class/hwmon/hwmon[0-*]:
148     |---name:                   The type of the thermal zone devices
149     |---temp[1-*]_input:        The current temperature of thermal zone [1-*]
150     |---temp[1-*]_critical:     The critical trip point of thermal zone [1-*]
151
152 Please read Documentation/hwmon/sysfs-interface for additional information.
153
154 ***************************
155 * Thermal zone attributes *
156 ***************************
157
158 type
159         Strings which represent the thermal zone type.
160         This is given by thermal zone driver as part of registration.
161         E.g: "acpitz" indicates it's an ACPI thermal device.
162         In order to keep it consistent with hwmon sys attribute; this should
163         be a short, lowercase string, not containing spaces nor dashes.
164         RO, Required
165
166 temp
167         Current temperature as reported by thermal zone (sensor).
168         Unit: millidegree Celsius
169         RO, Required
170
171 mode
172         One of the predefined values in [kernel, user].
173         This file gives information about the algorithm that is currently
174         managing the thermal zone. It can be either default kernel based
175         algorithm or user space application.
176         kernel  = Thermal management in kernel thermal zone driver.
177         user    = Preventing kernel thermal zone driver actions upon
178                   trip points so that user application can take full
179                   charge of the thermal management.
180         RW, Optional
181
182 trip_point_[0-*]_temp
183         The temperature above which trip point will be fired.
184         Unit: millidegree Celsius
185         RO, Optional
186
187 trip_point_[0-*]_type
188         Strings which indicate the type of the trip point.
189         E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
190         thermal zone.
191         RO, Optional
192
193 cdev[0-*]
194         Sysfs link to the thermal cooling device node where the sys I/F
195         for cooling device throttling control represents.
196         RO, Optional
197
198 cdev[0-*]_trip_point
199         The trip point with which cdev[0-*] is associated in this thermal
200         zone; -1 means the cooling device is not associated with any trip
201         point.
202         RO, Optional
203
204 passive
205         Attribute is only present for zones in which the passive cooling
206         policy is not supported by native thermal driver. Default is zero
207         and can be set to a temperature (in millidegrees) to enable a
208         passive trip point for the zone. Activation is done by polling with
209         an interval of 1 second.
210         Unit: millidegrees Celsius
211         Valid values: 0 (disabled) or greater than 1000
212         RW, Optional
213
214 *****************************
215 * Cooling device attributes *
216 *****************************
217
218 type
219         String which represents the type of device, e.g:
220         - for generic ACPI: should be "Fan", "Processor" or "LCD"
221         - for memory controller device on intel_menlow platform:
222           should be "Memory controller".
223         RO, Required
224
225 max_state
226         The maximum permissible cooling state of this cooling device.
227         RO, Required
228
229 cur_state
230         The current cooling state of this cooling device.
231         The value can any integer numbers between 0 and max_state:
232         - cur_state == 0 means no cooling
233         - cur_state == max_state means the maximum cooling.
234         RW, Required
235
236 3. A simple implementation
237
238 ACPI thermal zone may support multiple trip points like critical, hot,
239 passive, active. If an ACPI thermal zone supports critical, passive,
240 active[0] and active[1] at the same time, it may register itself as a
241 thermal_zone_device (thermal_zone1) with 4 trip points in all.
242 It has one processor and one fan, which are both registered as
243 thermal_cooling_device.
244
245 If the processor is listed in _PSL method, and the fan is listed in _AL0
246 method, the sys I/F structure will be built like this:
247
248 /sys/class/thermal:
249
250 |thermal_zone1:
251     |---type:                   acpitz
252     |---temp:                   37000
253     |---mode:                   kernel
254     |---trip_point_0_temp:      100000
255     |---trip_point_0_type:      critical
256     |---trip_point_1_temp:      80000
257     |---trip_point_1_type:      passive
258     |---trip_point_2_temp:      70000
259     |---trip_point_2_type:      active0
260     |---trip_point_3_temp:      60000
261     |---trip_point_3_type:      active1
262     |---cdev0:                  --->/sys/class/thermal/cooling_device0
263     |---cdev0_trip_point:       1       /* cdev0 can be used for passive */
264     |---cdev1:                  --->/sys/class/thermal/cooling_device3
265     |---cdev1_trip_point:       2       /* cdev1 can be used for active[0]*/
266
267 |cooling_device0:
268     |---type:                   Processor
269     |---max_state:              8
270     |---cur_state:              0
271
272 |cooling_device3:
273     |---type:                   Fan
274     |---max_state:              2
275     |---cur_state:              0
276
277 /sys/class/hwmon:
278
279 |hwmon0:
280     |---name:                   acpitz
281     |---temp1_input:            37000
282     |---temp1_crit:             100000
283
284 4. Event Notification
285
286 The framework includes a simple notification mechanism, in the form of a
287 netlink event. Netlink socket initialization is done during the _init_
288 of the framework. Drivers which intend to use the notification mechanism
289 just need to call thermal_generate_netlink_event() with two arguments viz
290 (originator, event). Typically the originator will be an integer assigned
291 to a thermal_zone_device when it registers itself with the framework. The
292 event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,