1 .. SPDX-License-Identifier: GPL-2.0
3 ===============================================
4 Ingenic JZ47xx SoCs Timer/Counter Unit hardware
5 ===============================================
7 The Timer/Counter Unit (TCU) in Ingenic JZ47xx SoCs is a multi-function
8 hardware block. It features up to to eight channels, that can be used as
9 counters, timers, or PWM.
11 - JZ4725B, JZ4750, JZ4755 only have six TCU channels. The other SoCs all
14 - JZ4725B introduced a separate channel, called Operating System Timer
15 (OST). It is a 32-bit programmable timer. On JZ4760B and above, it is
18 - Each one of the TCU channels has its own clock, which can be reparented to three
19 different clocks (pclk, ext, rtc), gated, and reclocked, through their TCSR register.
21 - The watchdog and OST hardware blocks also feature a TCSR register with the same
22 format in their register space.
23 - The TCU registers used to gate/ungate can also gate/ungate the watchdog and
26 - Each TCU channel works in one of two modes:
28 - mode TCU1: channels cannot work in sleep mode, but are easier to
30 - mode TCU2: channels can work in sleep mode, but the operation is a bit
31 more complicated than with TCU1 channels.
33 - The mode of each TCU channel depends on the SoC used:
35 - On the oldest SoCs (up to JZ4740), all of the eight channels operate in
37 - On JZ4725B, channel 5 operates as TCU2, the others operate as TCU1.
38 - On newest SoCs (JZ4750 and above), channels 1-2 operate as TCU2, the
39 others operate as TCU1.
41 - Each channel can generate an interrupt. Some channels share an interrupt
42 line, some don't, and this changes between SoC versions:
44 - on older SoCs (JZ4740 and below), channel 0 and channel 1 have their
45 own interrupt line; channels 2-7 share the last interrupt line.
46 - On JZ4725B, channel 0 has its own interrupt; channels 1-5 share one
47 interrupt line; the OST uses the last interrupt line.
48 - on newer SoCs (JZ4750 and above), channel 5 has its own interrupt;
49 channels 0-4 and (if eight channels) 6-7 all share one interrupt line;
50 the OST uses the last interrupt line.
55 The functionalities of the TCU hardware are spread across multiple drivers:
58 clocks drivers/clk/ingenic/tcu.c
59 interrupts drivers/irqchip/irq-ingenic-tcu.c
60 timers drivers/clocksource/ingenic-timer.c
61 OST drivers/clocksource/ingenic-ost.c
62 PWM drivers/pwm/pwm-jz4740.c
63 watchdog drivers/watchdog/jz4740_wdt.c
66 Because various functionalities of the TCU that belong to different drivers
67 and frameworks can be controlled from the same registers, all of these
68 drivers access their registers through the same regmap.
70 For more information regarding the devicetree bindings of the TCU drivers,
71 have a look at Documentation/devicetree/bindings/timer/ingenic,tcu.yaml.