10 Addresses scanned: none
12 Datasheet: https://www.sensirion.com/file/datasheet_sht3x_digital
16 - David Frey <david.frey@sensirion.com>
17 - Pascal Sachs <pascal.sachs@sensirion.com>
22 This driver implements support for the Sensirion SHT3x-DIS chip, a humidity
23 and temperature sensor. Temperature is measured in degrees celsius, relative
24 humidity is expressed as a percentage. In the sysfs interface, all values are
25 scaled by 1000, i.e. the value for 31.5 degrees celsius is 31500.
27 The device communicates with the I2C protocol. Sensors can have the I2C
28 addresses 0x44 or 0x45, depending on the wiring. See
29 Documentation/i2c/instantiating-devices.rst for methods to instantiate the device.
31 There are two options configurable by means of sht3x_platform_data:
33 1. blocking (pull the I2C clock line down while performing the measurement) or
34 non-blocking mode. Blocking mode will guarantee the fastest result but
35 the I2C bus will be busy during that time. By default, non-blocking mode
36 is used. Make sure clock-stretching works properly on your device if you
37 want to use blocking mode.
38 2. high or low accuracy. High accuracy is used by default and using it is
41 The sht3x sensor supports a single shot mode as well as 5 periodic measure
42 modes, which can be controlled with the update_interval sysfs interface.
43 The allowed update_interval in milliseconds are as follows:
45 ===== ======= ====================
47 2000 0.5 Hz periodic measurement
48 1000 1 Hz periodic measurement
49 500 2 Hz periodic measurement
50 250 4 Hz periodic measurement
51 100 10 Hz periodic measurement
52 ===== ======= ====================
54 In the periodic measure mode, the sensor automatically triggers a measurement
55 with the configured update interval on the chip. When a temperature or humidity
56 reading exceeds the configured limits, the alert attribute is set to 1 and
57 the alert pin on the sensor is set to high.
58 When the temperature and humidity readings move back between the hysteresis
59 values, the alert bit is set to 0 and the alert pin on the sensor is set to
65 =================== ============================================================
66 temp1_input: temperature input
67 humidity1_input: humidity input
68 temp1_max: temperature max value
69 temp1_max_hyst: temperature hysteresis value for max limit
70 humidity1_max: humidity max value
71 humidity1_max_hyst: humidity hysteresis value for max limit
72 temp1_min: temperature min value
73 temp1_min_hyst: temperature hysteresis value for min limit
74 humidity1_min: humidity min value
75 humidity1_min_hyst: humidity hysteresis value for min limit
76 temp1_alarm: alarm flag is set to 1 if the temperature is outside the
77 configured limits. Alarm only works in periodic measure mode
78 humidity1_alarm: alarm flag is set to 1 if the humidity is outside the
79 configured limits. Alarm only works in periodic measure mode
80 heater_enable: heater enable, heating element removes excess humidity from
85 update_interval: update interval, 0 for single shot, interval in msec
86 for periodic measurement. If the interval is not supported
87 by the sensor, the next faster interval is chosen
88 =================== ============================================================