8 * Vivien Didelot <vivien.didelot@savoirfairelinux.com>
9 * Jerome Oufella <jerome.oufella@savoirfairelinux.com>
33 Datasheet: Publicly available at the Sensirion website
35 http://www.sensirion.ch/en/pdf/product_information/Datasheet-humidity-sensor-SHT1x.pdf
40 The SHT10, SHT11, SHT15, SHT71, and SHT75 are humidity and temperature
43 The devices communicate using two GPIO lines.
45 Supported resolutions for the measurements are 14 bits for temperature and 12
46 bits for humidity, or 12 bits for temperature and 8 bits for humidity.
48 The humidity calibration coefficients are programmed into an OTP memory on the
49 chip. These coefficients are used to internally calibrate the signals from the
50 sensors. Disabling the reload of those coefficients allows saving 10ms for each
51 measurement and decrease power consumption, while losing on precision.
53 Some options may be set via sysfs attributes.
56 * The regulator supply name is set to "vcc".
57 * If a CRC validation fails, a soft reset command is sent, which resets
58 status register to its hardware default value, but the driver will try to
59 restore the previous device configuration.
65 set it to true to enable CRC validation of the readings (default to false).
67 flag to indicate not to reload from OTP (default to false).
69 flag to indicate the temp/humidity resolution to use (default to false).
74 ================== ==========================================================
75 temp1_input temperature input
76 humidity1_input humidity input
77 heater_enable write 1 in this attribute to enable the on-chip heater,
78 0 to disable it. Be careful not to enable the heater
80 temp1_fault if 1, this means that the voltage is low (below 2.47V) and
81 measurement may be invalid.
82 humidity1_fault same as temp1_fault.
83 ================== ==========================================================