Merge tag 'io_uring-6.5-2023-07-03' of git://git.kernel.dk/linux
[platform/kernel/linux-starfive.git] / Documentation / hwmon / peci-dimmtemp.rst
1 .. SPDX-License-Identifier: GPL-2.0
2
3 Kernel driver peci-dimmtemp
4 ===========================
5
6 Supported chips:
7         One of Intel server CPUs listed below which is connected to a PECI bus.
8                 * Intel Xeon E5/E7 v3 server processors
9                         Intel Xeon E5-14xx v3 family
10                         Intel Xeon E5-24xx v3 family
11                         Intel Xeon E5-16xx v3 family
12                         Intel Xeon E5-26xx v3 family
13                         Intel Xeon E5-46xx v3 family
14                         Intel Xeon E7-48xx v3 family
15                         Intel Xeon E7-88xx v3 family
16                 * Intel Xeon E5/E7 v4 server processors
17                         Intel Xeon E5-16xx v4 family
18                         Intel Xeon E5-26xx v4 family
19                         Intel Xeon E5-46xx v4 family
20                         Intel Xeon E7-48xx v4 family
21                         Intel Xeon E7-88xx v4 family
22                 * Intel Xeon Scalable server processors
23                         Intel Xeon D family
24                         Intel Xeon Bronze family
25                         Intel Xeon Silver family
26                         Intel Xeon Gold family
27                         Intel Xeon Platinum family
28
29         Datasheet: Available from http://www.intel.com/design/literature.htm
30
31 Author: Jae Hyun Yoo <jae.hyun.yoo@linux.intel.com>
32
33 Description
34 -----------
35
36 This driver implements a generic PECI hwmon feature which provides
37 Temperature sensor on DIMM readings that are accessible via the processor PECI interface.
38
39 All temperature values are given in millidegree Celsius and will be measurable
40 only when the target CPU is powered on.
41
42 Sysfs interface
43 -------------------
44
45 ======================= =======================================================
46
47 temp[N]_label           Provides string "DIMM CI", where C is DIMM channel and
48                         I is DIMM index of the populated DIMM.
49 temp[N]_input           Provides current temperature of the populated DIMM.
50 temp[N]_max             Provides thermal control temperature of the DIMM.
51 temp[N]_crit            Provides shutdown temperature of the DIMM.
52
53 ======================= =======================================================
54
55 Note:
56         DIMM temperature attributes will appear when the client CPU's BIOS
57         completes memory training and testing.