Merge remote-tracking branch 'stable/linux-5.15.y' into rpi-5.15.y
[platform/kernel/linux-rpi.git] / Documentation / hwmon / lm90.rst
1 Kernel driver lm90
2 ==================
3
4 Supported chips:
5
6   * National Semiconductor LM90
7
8     Prefix: 'lm90'
9
10     Addresses scanned: I2C 0x4c
11
12     Datasheet: Publicly available at the National Semiconductor website
13
14                http://www.national.com/pf/LM/LM90.html
15
16   * National Semiconductor LM89
17
18     Prefix: 'lm89' (no auto-detection)
19
20     Addresses scanned: I2C 0x4c and 0x4d
21
22     Datasheet: Publicly available at the National Semiconductor website
23
24                http://www.national.com/mpf/LM/LM89.html
25
26   * National Semiconductor LM99
27
28     Prefix: 'lm99'
29
30     Addresses scanned: I2C 0x4c and 0x4d
31
32     Datasheet: Publicly available at the National Semiconductor website
33
34                http://www.national.com/pf/LM/LM99.html
35
36   * National Semiconductor LM86
37
38     Prefix: 'lm86'
39
40     Addresses scanned: I2C 0x4c
41
42     Datasheet: Publicly available at the National Semiconductor website
43
44                http://www.national.com/mpf/LM/LM86.html
45
46   * Analog Devices ADM1032
47
48     Prefix: 'adm1032'
49
50     Addresses scanned: I2C 0x4c and 0x4d
51
52     Datasheet: Publicly available at the ON Semiconductor website
53
54                https://www.onsemi.com/PowerSolutions/product.do?id=ADM1032
55
56   * Analog Devices ADT7461
57
58     Prefix: 'adt7461'
59
60     Addresses scanned: I2C 0x4c and 0x4d
61
62     Datasheet: Publicly available at the ON Semiconductor website
63
64                https://www.onsemi.com/PowerSolutions/product.do?id=ADT7461
65
66   * Analog Devices ADT7461A
67
68     Prefix: 'adt7461a'
69
70     Addresses scanned: I2C 0x4c and 0x4d
71
72     Datasheet: Publicly available at the ON Semiconductor website
73
74                https://www.onsemi.com/PowerSolutions/product.do?id=ADT7461A
75
76   * ON Semiconductor NCT1008
77
78     Prefix: 'nct1008'
79
80     Addresses scanned: I2C 0x4c and 0x4d
81
82     Datasheet: Publicly available at the ON Semiconductor website
83
84                https://www.onsemi.com/PowerSolutions/product.do?id=NCT1008
85
86   * Maxim MAX6646
87
88     Prefix: 'max6646'
89
90     Addresses scanned: I2C 0x4d
91
92     Datasheet: Publicly available at the Maxim website
93
94                http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3497
95
96   * Maxim MAX6647
97
98     Prefix: 'max6646'
99
100     Addresses scanned: I2C 0x4e
101
102     Datasheet: Publicly available at the Maxim website
103
104                http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3497
105
106   * Maxim MAX6648
107
108     Prefix: 'max6646'
109
110     Addresses scanned: I2C 0x4c
111
112     Datasheet: Publicly available at the Maxim website
113
114                http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3500
115
116   * Maxim MAX6649
117
118     Prefix: 'max6646'
119
120     Addresses scanned: I2C 0x4c
121
122     Datasheet: Publicly available at the Maxim website
123
124                http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3497
125
126   * Maxim MAX6654
127
128     Prefix: 'max6654'
129
130     Addresses scanned: I2C 0x18, 0x19, 0x1a, 0x29, 0x2a, 0x2b,
131
132                            0x4c, 0x4d and 0x4e
133
134     Datasheet: Publicly available at the Maxim website
135
136                https://www.maximintegrated.com/en/products/sensors/MAX6654.html
137
138   * Maxim MAX6657
139
140     Prefix: 'max6657'
141
142     Addresses scanned: I2C 0x4c
143
144     Datasheet: Publicly available at the Maxim website
145
146                http://www.maxim-ic.com/quick_view2.cfm/qv_pk/2578
147
148   * Maxim MAX6658
149
150     Prefix: 'max6657'
151
152     Addresses scanned: I2C 0x4c
153
154     Datasheet: Publicly available at the Maxim website
155
156                http://www.maxim-ic.com/quick_view2.cfm/qv_pk/2578
157
158   * Maxim MAX6659
159
160     Prefix: 'max6659'
161
162     Addresses scanned: I2C 0x4c, 0x4d, 0x4e
163
164     Datasheet: Publicly available at the Maxim website
165
166                http://www.maxim-ic.com/quick_view2.cfm/qv_pk/2578
167
168   * Maxim MAX6680
169
170     Prefix: 'max6680'
171
172     Addresses scanned: I2C 0x18, 0x19, 0x1a, 0x29, 0x2a, 0x2b,
173
174                            0x4c, 0x4d and 0x4e
175
176     Datasheet: Publicly available at the Maxim website
177
178                http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3370
179
180   * Maxim MAX6681
181
182     Prefix: 'max6680'
183
184     Addresses scanned: I2C 0x18, 0x19, 0x1a, 0x29, 0x2a, 0x2b,
185
186                            0x4c, 0x4d and 0x4e
187
188     Datasheet: Publicly available at the Maxim website
189
190                http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3370
191
192   * Maxim MAX6692
193
194     Prefix: 'max6646'
195
196     Addresses scanned: I2C 0x4c
197
198     Datasheet: Publicly available at the Maxim website
199
200                http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3500
201
202   * Maxim MAX6695
203
204     Prefix: 'max6695'
205
206     Addresses scanned: I2C 0x18
207
208     Datasheet: Publicly available at the Maxim website
209
210                http://www.maxim-ic.com/datasheet/index.mvp/id/4199
211
212   * Maxim MAX6696
213
214     Prefix: 'max6695'
215
216     Addresses scanned: I2C 0x18, 0x19, 0x1a, 0x29, 0x2a, 0x2b,
217
218                            0x4c, 0x4d and 0x4e
219
220     Datasheet: Publicly available at the Maxim website
221
222                http://www.maxim-ic.com/datasheet/index.mvp/id/4199
223
224   * Winbond/Nuvoton W83L771W/G
225
226     Prefix: 'w83l771'
227
228     Addresses scanned: I2C 0x4c
229
230     Datasheet: No longer available
231
232   * Winbond/Nuvoton W83L771AWG/ASG
233
234     Prefix: 'w83l771'
235
236     Addresses scanned: I2C 0x4c
237
238     Datasheet: Not publicly available, can be requested from Nuvoton
239
240   * Philips/NXP SA56004X
241
242     Prefix: 'sa56004'
243
244     Addresses scanned: I2C 0x48 through 0x4F
245
246     Datasheet: Publicly available at NXP website
247
248                http://ics.nxp.com/products/interface/datasheet/sa56004x.pdf
249
250   * GMT G781
251
252     Prefix: 'g781'
253
254     Addresses scanned: I2C 0x4c, 0x4d
255
256     Datasheet: Not publicly available from GMT
257
258   * Texas Instruments TMP451
259
260     Prefix: 'tmp451'
261
262     Addresses scanned: I2C 0x4c
263
264     Datasheet: Publicly available at TI website
265
266                https://www.ti.com/litv/pdf/sbos686
267
268   * Texas Instruments TMP461
269
270     Prefix: 'tmp461'
271
272     Addresses scanned: I2C 0x48 through 0x4F
273
274     Datasheet: Publicly available at TI website
275
276                https://www.ti.com/lit/gpn/tmp461
277
278 Author: Jean Delvare <jdelvare@suse.de>
279
280
281 Description
282 -----------
283
284 The LM90 is a digital temperature sensor. It senses its own temperature as
285 well as the temperature of up to one external diode. It is compatible
286 with many other devices, many of which are supported by this driver.
287
288 Note that there is no easy way to differentiate between the MAX6657,
289 MAX6658 and MAX6659 variants. The extra features of the MAX6659 are only
290 supported by this driver if the chip is located at address 0x4d or 0x4e,
291 or if the chip type is explicitly selected as max6659.
292 The MAX6680 and MAX6681 only differ in their pinout, therefore they obviously
293 can't (and don't need to) be distinguished.
294
295 The specificity of this family of chipsets over the ADM1021/LM84
296 family is that it features critical limits with hysteresis, and an
297 increased resolution of the remote temperature measurement.
298
299 The different chipsets of the family are not strictly identical, although
300 very similar. For reference, here comes a non-exhaustive list of specific
301 features:
302
303 LM90:
304   * Filter and alert configuration register at 0xBF.
305   * ALERT is triggered by temperatures over critical limits.
306
307 LM86 and LM89:
308   * Same as LM90
309   * Better external channel accuracy
310
311 LM99:
312   * Same as LM89
313   * External temperature shifted by 16 degrees down
314
315 ADM1032:
316   * Consecutive alert register at 0x22.
317   * Conversion averaging.
318   * Up to 64 conversions/s.
319   * ALERT is triggered by open remote sensor.
320   * SMBus PEC support for Write Byte and Receive Byte transactions.
321
322 ADT7461, ADT7461A, NCT1008:
323   * Extended temperature range (breaks compatibility)
324   * Lower resolution for remote temperature
325
326 MAX6654:
327   * Better local resolution
328   * Selectable address
329   * Remote sensor type selection
330   * Extended temperature range
331   * Extended resolution only available when conversion rate <= 1 Hz
332
333 MAX6657 and MAX6658:
334   * Better local resolution
335   * Remote sensor type selection
336
337 MAX6659:
338   * Better local resolution
339   * Selectable address
340   * Second critical temperature limit
341   * Remote sensor type selection
342
343 MAX6680 and MAX6681:
344   * Selectable address
345   * Remote sensor type selection
346
347 MAX6695 and MAX6696:
348   * Better local resolution
349   * Selectable address (max6696)
350   * Second critical temperature limit
351   * Two remote sensors
352
353 W83L771W/G
354   * The G variant is lead-free, otherwise similar to the W.
355   * Filter and alert configuration register at 0xBF
356   * Moving average (depending on conversion rate)
357
358 W83L771AWG/ASG
359   * Successor of the W83L771W/G, same features.
360   * The AWG and ASG variants only differ in package format.
361   * Diode ideality factor configuration (remote sensor) at 0xE3
362
363 SA56004X:
364   * Better local resolution
365
366 All temperature values are given in degrees Celsius. Resolution
367 is 1.0 degree for the local temperature, 0.125 degree for the remote
368 temperature, except for the MAX6654, MAX6657, MAX6658 and MAX6659 which have
369 a resolution of 0.125 degree for both temperatures.
370
371 Each sensor has its own high and low limits, plus a critical limit.
372 Additionally, there is a relative hysteresis value common to both critical
373 values. To make life easier to user-space applications, two absolute values
374 are exported, one for each channel, but these values are of course linked.
375 Only the local hysteresis can be set from user-space, and the same delta
376 applies to the remote hysteresis.
377
378 The lm90 driver will not update its values more frequently than configured with
379 the update_interval attribute; reading them more often will do no harm, but will
380 return 'old' values.
381
382 SMBus Alert Support
383 -------------------
384
385 This driver has basic support for SMBus alert. When an alert is received,
386 the status register is read and the faulty temperature channel is logged.
387
388 The Analog Devices chips (ADM1032, ADT7461 and ADT7461A) and ON
389 Semiconductor chips (NCT1008) do not implement the SMBus alert protocol
390 properly so additional care is needed: the ALERT output is disabled when
391 an alert is received, and is re-enabled only when the alarm is gone.
392 Otherwise the chip would block alerts from other chips in the bus as long
393 as the alarm is active.
394
395 PEC Support
396 -----------
397
398 The ADM1032 is the only chip of the family which supports PEC. It does
399 not support PEC on all transactions though, so some care must be taken.
400
401 When reading a register value, the PEC byte is computed and sent by the
402 ADM1032 chip. However, in the case of a combined transaction (SMBus Read
403 Byte), the ADM1032 computes the CRC value over only the second half of
404 the message rather than its entirety, because it thinks the first half
405 of the message belongs to a different transaction. As a result, the CRC
406 value differs from what the SMBus master expects, and all reads fail.
407
408 For this reason, the lm90 driver will enable PEC for the ADM1032 only if
409 the bus supports the SMBus Send Byte and Receive Byte transaction types.
410 These transactions will be used to read register values, instead of
411 SMBus Read Byte, and PEC will work properly.
412
413 Additionally, the ADM1032 doesn't support SMBus Send Byte with PEC.
414 Instead, it will try to write the PEC value to the register (because the
415 SMBus Send Byte transaction with PEC is similar to a Write Byte transaction
416 without PEC), which is not what we want. Thus, PEC is explicitly disabled
417 on SMBus Send Byte transactions in the lm90 driver.
418
419 PEC on byte data transactions represents a significant increase in bandwidth
420 usage (+33% for writes, +25% for reads) in normal conditions. With the need
421 to use two SMBus transaction for reads, this overhead jumps to +50%. Worse,
422 two transactions will typically mean twice as much delay waiting for
423 transaction completion, effectively doubling the register cache refresh time.
424 I guess reliability comes at a price, but it's quite expensive this time.
425
426 So, as not everyone might enjoy the slowdown, PEC can be disabled through
427 sysfs. Just write 0 to the "pec" file and PEC will be disabled. Write 1
428 to that file to enable PEC again.