Correct .gbs.conf settings
[platform/adaptation/renesas_rcar/renesas_kernel.git] / Documentation / hwmon / ds1621
1 Kernel driver ds1621
2 ====================
3
4 Supported chips:
5   * Dallas Semiconductor / Maxim Integrated DS1621
6     Prefix: 'ds1621'
7     Addresses scanned: none
8     Datasheet: Publicly available from www.maximintegrated.com
9
10   * Dallas Semiconductor DS1625
11     Prefix: 'ds1625'
12     Addresses scanned: none
13     Datasheet: Publicly available from www.datasheetarchive.com
14
15   * Maxim Integrated DS1631
16     Prefix: 'ds1631'
17     Addresses scanned: none
18     Datasheet: Publicly available from www.maximintegrated.com
19
20   * Maxim Integrated DS1721
21     Prefix: 'ds1721'
22     Addresses scanned: none
23     Datasheet: Publicly available from www.maximintegrated.com
24
25   * Maxim Integrated DS1731
26     Prefix: 'ds1731'
27     Addresses scanned: none
28     Datasheet: Publicly available from www.maximintegrated.com
29
30 Authors:
31         Christian W. Zuckschwerdt <zany@triq.net>
32         valuable contributions by Jan M. Sendler <sendler@sendler.de>
33         ported to 2.6 by Aurelien Jarno <aurelien@aurel32.net>
34         with the help of Jean Delvare <jdelvare@suse.de>
35
36 Module Parameters
37 ------------------
38
39 * polarity int
40   Output's polarity: 0 = active high, 1 = active low
41
42 Description
43 -----------
44
45 The DS1621 is a (one instance) digital thermometer and thermostat. It has
46 both high and low temperature limits which can be user defined (i.e.
47 programmed into non-volatile on-chip registers). Temperature range is -55
48 degree Celsius to +125 in 0.5 increments. You may convert this into a
49 Fahrenheit range of -67 to +257 degrees with 0.9 steps. If polarity
50 parameter is not provided, original value is used.
51
52 As for the thermostat, behavior can also be programmed using the polarity
53 toggle. On the one hand ("heater"), the thermostat output of the chip,
54 Tout, will trigger when the low limit temperature is met or underrun and
55 stays high until the high limit is met or exceeded. On the other hand
56 ("cooler"), vice versa. That way "heater" equals "active low", whereas
57 "conditioner" equals "active high". Please note that the DS1621 data sheet
58 is somewhat misleading in this point since setting the polarity bit does
59 not simply invert Tout.
60
61 A second thing is that, during extensive testing, Tout showed a tolerance
62 of up to +/- 0.5 degrees even when compared against precise temperature
63 readings. Be sure to have a high vs. low temperature limit gap of al least
64 1.0 degree Celsius to avoid Tout "bouncing", though!
65
66 The alarm bits are set when the high or low limits are met or exceeded and
67 are reset by the module as soon as the respective temperature ranges are
68 left.
69
70 The alarm registers are in no way suitable to find out about the actual
71 status of Tout. They will only tell you about its history, whether or not
72 any of the limits have ever been met or exceeded since last power-up or
73 reset. Be aware: When testing, it showed that the status of Tout can change
74 with neither of the alarms set.
75
76 Since there is no version or vendor identification register, there is
77 no unique identification for these devices. Therefore, explicit device
78 instantiation is required for correct device identification and functionality
79 (one device per address in this address range: 0x48..0x4f).
80
81 The DS1625 is pin compatible and functionally equivalent with the DS1621,
82 but the DS1621 is meant to replace it. The DS1631, DS1721, and DS1731 are
83 also pin compatible with the DS1621 and provide multi-resolution support.
84
85 Additionally, the DS1721 data sheet says the temperature flags (THF and TLF)
86 are used internally, however, these flags do get set and cleared as the actual
87 temperature crosses the min or max settings (which by default are set to 75
88 and 80 degrees respectively).
89
90 Temperature Conversion:
91 -----------------------
92 DS1621 - 750ms (older devices may take up to 1000ms)
93 DS1625 - 500ms
94 DS1631 - 93ms..750ms for 9..12 bits resolution, respectively.
95 DS1721 - 93ms..750ms for 9..12 bits resolution, respectively.
96 DS1731 - 93ms..750ms for 9..12 bits resolution, respectively.
97
98 Note:
99 On the DS1621, internal access to non-volatile registers may last for 10ms
100 or less (unverified on the other devices).
101
102 Temperature Accuracy:
103 ---------------------
104 DS1621: +/- 0.5 degree Celsius (from 0 to +70 degrees)
105 DS1625: +/- 0.5 degree Celsius (from 0 to +70 degrees)
106 DS1631: +/- 0.5 degree Celsius (from 0 to +70 degrees)
107 DS1721: +/- 1.0 degree Celsius (from -10 to +85 degrees)
108 DS1731: +/- 1.0 degree Celsius (from -10 to +85 degrees)
109
110 Note:
111 Please refer to the device datasheets for accuracy at other temperatures.
112
113 Temperature Resolution:
114 -----------------------
115 As mentioned above, the DS1631, DS1721, and DS1731 provide multi-resolution
116 support, which is achieved via the R0 and R1 config register bits, where:
117
118 R0..R1
119 ------
120  0  0 => 9 bits, 0.5 degrees Celcius
121  1  0 => 10 bits, 0.25 degrees Celcius
122  0  1 => 11 bits, 0.125 degrees Celcius
123  1  1 => 12 bits, 0.0625 degrees Celcius
124
125 Note:
126 At initial device power-on, the default resolution is set to 12-bits.
127
128 The resolution mode for the DS1631, DS1721, or DS1731 can be changed from
129 userspace, via the device 'update_interval' sysfs attribute. This attribute
130 will normalize the range of input values to the device maximum resolution
131 values defined in the datasheet as follows:
132
133 Resolution    Conversion Time    Input Range
134  (C/LSB)       (msec)             (msec)
135 ------------------------------------------------
136 0.5             93.75              0....94
137 0.25            187.5              95...187
138 0.125           375                188..375
139 0.0625          750                376..infinity
140 ------------------------------------------------
141
142 The following examples show how the 'update_interval' attribute can be
143 used to change the conversion time:
144
145 $ cat update_interval
146 750
147 $ cat temp1_input
148 22062
149 $
150 $ echo 300 > update_interval
151 $ cat update_interval
152 375
153 $ cat temp1_input
154 22125
155 $
156 $ echo 150 > update_interval
157 $ cat update_interval
158 188
159 $ cat temp1_input
160 22250
161 $
162 $ echo 1 > update_interval
163 $ cat update_interval
164 94
165 $ cat temp1_input
166 22000
167 $
168 $ echo 1000 > update_interval
169 $ cat update_interval
170 750
171 $ cat temp1_input
172 22062
173 $
174
175 As shown, the ds1621 driver automatically adjusts the 'update_interval'
176 user input, via a step function. Reading back the 'update_interval' value
177 after a write operation provides the conversion time used by the device.
178
179 Mathematically, the resolution can be derived from the conversion time
180 via the following function:
181
182    g(x) = 0.5 * [minimum_conversion_time/x]
183
184 where:
185  -> 'x' = the output from 'update_interval'
186  -> 'g(x)' = the resolution in degrees C per LSB.
187  -> 93.75ms = minimum conversion time